User Guide 2
USER GUIDE
 Anti-Tip Bracket 1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
CAUTION
!
The anti-tip bracket must be installed to prevent 
the unit from tipping when doors are fully 
opened or excess weight is placed on the front of 
the unit.
The anti-tip bracket has multiple mounting options. 
Mounting will depend on your particular cabinet 
configuration. Locate 3 #8x5/8" screws included with your 
unit.
TOP MOUNT
For ease of installation, the anti-tip bracket is pre-installed 
in the top mount position.
1. Completely slide the unit into its position in the 
cabinet. Be certain unit height is properly adjusted. 
(See GENERAL INSTALLATION).
2. Open door completely. Make certain door clears 
surrounding cabinetry.
3. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8" 
(16 mm) deep into bottom of counter top. Use the 
anti-tip bracket as a template.
4. Install 3 #8x5/8" screws into the plate using a 
#2 Phillips head screwdriver.
SIDE MOUNT
Side mount position is used when you are unable to mount 
the bracket to the underside of your countertop.
1. Remove the pre-installed anti-tip bracket from the top 
mount position and align the bracket to the hinge side 
of the unit as shown above. 
2. Reinstall the 2 #8x5/8" screws into the plate using a 
#2 Phillips head screwdriver. 
3. Completely slide the unit into its position in the 
cabinet. Be certain unit height is properly adjusted. 
(See GENERAL INSTALLATION).
4. Open door completely. Make certain door clears 
surrounding cabinetry.
5. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8" 
(16 mm) deep into cabinetry frame using the anti-tip 
bracket as a template.
6. Install 3 #8x5/8" screws into the plate using a #2 
Phillips head screwdriver.
Left Hinged Cabinet
Right Hinged Cabinet