Service manual
21
Service Information
CAUTION
If you use a vacuum pump with mineral oil to
evacuate an R-134a system, it is ABSOLUTELY
ESSENTIAL to have a shut-off valve between
pump and your manifold gauge set as shown
in Figure E2. The hand valve must be closed
during all times when vacuum pump is
not operating. This will prevent migration
of mineral oil vapor into R134a/Ester oil
system. If vacuum pump should stop during
evacuation for any reason, the hand pump
shut-off valve must be closed immediately.
Refrigerant Leaks
AsystemwithR-134aandEsteroilwillbecome
saturatedwithmoisturemuchfasterthanasystem
withR-12andmineraloil.Ifyourleakwasinthe
lowsideoftherefrigerationsystemwhenthe
compressorisrunningthepressureinthelowside
willgointoavacuum.Asadditionalrefrigerant
leaksoutthesystemwillgodeeperintoavacuum.
Thesystemrunninginthisvacuumwillallowair
andmoisturetobepulledintothesealedsystem.
Themoisturepulledincanthenbemixedintothe
Esteroilinthecompressor.
Iftheproducthashadalowsideleakyouwillneed
toinstallthetwostageservicedryerlterpart
number5303918288.Youmustheatthecrankcase
areaofthecompressorusingaheatgunonthe
highheatsettingthoughoutthe30minutesyouare
runningyourvacuumpumptopullavacuumonthe
system.Every4to5minuteswhileyouarerunning
yourvacuumpumpandheatingthecrankcasearea
shakethecompressor.Byheatingthecrank-case
youareheatingtheoilinthecompressor.Thiswill
drivethemoistureoutoftheoil.Byshakingthe
compressorthiswillallowthemoisturetocometo
thetopoftheoilfastersothevacuumpumpcan
removethemoisturefromthesystem.
Electrolux Home products does not approve
the use of the Sweep Charge for sealed system
repair. Thismethodofservicingsealedsystems
weknowisoftenusedtorepairproductsinthe
eld.TheSweepChargedoesnotadequately
removethemoisturefromtheoilinthecompressor.
InaR-134asystemyouwillneedtoreplacedthe
compressoriftheproducthashadalowsideleak
andyouareservicingwiththeSweepCharge
procedure.
R-134arefrigerantmoleculesaresmallerthan
R-12molecules.ThismeansthatR-134awillpass
moreminorleaksandtherateofowwillbegreater
thanforR-12.Therefore,itisnowmoreimportant
thanevertofollowgoodbrazingpractices.Usea
goodgradeofsilversolder.45%silversolderis
recommended.
Leak Detection
R-134asystemleakscanbepinpointedbymeansof
anelectronicleakdetectororbybubblesolution.
ElectronicleakdetectorsforR-134aserviceare
currentlyavailablefromseveralmanufacturers.The
leastexpensivemodelsarenon-selectivedetectors
thatwilldetectanytypeofemissionorvaporpresent,
regardlessofitschemicalcomposition.Somenon-
selectivedetectorsdesignedforusewithR-12
mayhaveamuchlowersensitivitywhenusedwith
R-134a.However,newlydesigneddetectorswith
goodR-134asensitivityarenowavailable.Besure
toconsultwiththemanufacturerbeforeselectingor
usinganon-selectivedetectorwithR-134a.
Halogen-specicdetectorsuseaspecializedsensor
thatallowsdetectionofcompoundscontaining
chlorine,uorine,bromine,andiodinewithoutbeing
activiatedbyotherspecies.Themajoradvantage
ofthistypeofdetectorisareductioninthenumber
of“nuisancealarms”.Halogen-specicdetectors
aregenerallymoreexpensivethannon-selective
detectorsbutfeaturehighersensitivity.