QUICK START GUIDE Ice Makers • 115 V / 60 Hz & 220-240 V / 50 Hz
QUICK START GUIDE u-line.com WELCOME TO U-LINE Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine use.
QUICK START GUIDE Contents 1 Model List 3 Safety and Warning 4 Environmental Requirements 5 Electrical 6 Water Hookup 9 Door Swing 10 General Installation 11 Integrated Panel Installation 13 First Use 14 Ice 14 Warranty u-line.
QUICK START GUIDE u-line.com Model List This guide provides the basics to get you started. Looking for more information? Visit u-line.com to view detailed User Guides for all U-Line products.
QUICK START GUIDE u-line.com Marine Series ULN-BI95FCB-03A ULN-WH95FC-03A ULN-SS1095FC-03A ULN-BI95FCB-20A ULN-WH95FC-20A ULN-SS1095FC-20A ULN-SS1095FD-03A ULN-SS1095FD-20A ULN-SS1095NF-03A ULN-SS1095NF-20A ULN-SP18FCS-03A ULN-SP18FCS-20A ULN-SP18FCB-03A ULN-SP18FCB-20A ULN-SP18FCW-03A ULN-SP18FCW-20A ULN-SS98NF-03A ULN-SS98NF-20A Visit http://www.u-line.com/product-literature/userguides or scan this QR code to view all user guides online.
QUICK START GUIDE u-line.com Safety and Warning ! DANGER NOTICE Do not use electrical appliances inside the food PLEASE READ all instructions before installing, storage compartment of this appliance. operating, or servicing the appliance. SAFETY ALERT DEFINITIONS ! WARNING Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type: Keep ventilation openings in the appliance enclosure or in the built in structure clear of obstruction.
QUICK START GUIDE u-line.com This appliance is intended to be used in household and ! CAUTION similar applications such as: Use care when moving and handling the unit. • Staff kitchen areas in shops, office and other working Use gloves to prevent personal injury from sharp environments. edges. • Farm houses and by clients in hotels, motels and other If your model requires defrosting, DO NOT use residential type environments. medical devices or other means to accelerate the defrosting process.
QUICK START GUIDE u-line.com 220-240 V UNITS ! CAUTION This model is intended for indoor/interior applications only and is not to be used in installations that are open/ Damages caused by ambient temperatures of exposed to natural elements. 40°F (4°C) or below are not covered by the warranty. This unit is designed to operate between 50°F (10°C) and 90°F (32°C). Higher ambient temperatures may reduce the unit’s ability to reach low temperatures and/or reduce ice production on applicable models.
QUICK START GUIDE u-line.com The unit requires a grounded and polarized 115 VAC, The unit requires a grounded and polarized 230 VAC, 60 Hz, 15A power supply (normal household current). An 50 Hz, 8A power supply (normal household current). An individual, properly grounded branch circuit or circuit individual, properly grounded branch circuit or circuit breaker is recommended. A GFCI (ground fault circuit breaker is recommended.
QUICK START GUIDE u-line.com 2. Remove the grille/access panel in the front and the • The water line should be looped into 2 coils. This will back panel. allow the unit to be removed for cleaning and servicing. Make certain that the tubing is not pinched or damaged during installation. 3. Locate water valve in the front of the unit and ! WARNING thread water supply line Connect to potable water supply only. through.
QUICK START GUIDE u-line.com • The water pressure should be between 20 and 120 psi 6. Turn on water supply and check for leaks. (138 and 827 kPa). 7. Reinstall back panel and grille/front access panel. • The water line MUST have a shut-off valve in the supply line. 8. Install retaining clip. • The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and servicing. Make certain that the tubing is not pinched or damaged during installation.
QUICK START GUIDE u-line.com 9. Install retaining clip. 1. Turn off water supply and disconnect electrical supply to product prior to attempting installation. 2. Remove the back panel. 3. Locate water valve inlet. Door Swing 4. Break away filler feature in bushing with flat 1200 SERIES screwdriver. Wall Wall 1/4" Min. (6 mm) 2-1/8" Min. (54 mm) Remove ZLWK ɠDW screwdriver 5. Thread water line through back panel hole (with bushing). 6.
QUICK START GUIDE u-line.com General Installation Integrated models require 1/4" (6 mm) clearance if installed next to a wall. Allow for additional space for any MARINE AND BI SERIES knobs or pulls installed on the integrated panel/frame. LEVELING INFORMATION NOTICE BI SERIES Because these units do not have leveling legs, it is extremely important that they sit on a level surface. If they are not level, the ice mold will 1/4" Min. (6 mm) not fill evenly. Use a level to confirm the unit is level.
QUICK START GUIDE u-line.com 1200 SERIES INSTALLATION LEVELING INFORMATION 1. Plug in the power/electrical cord. 1. Use a level to confirm the unit is 2. Gently push the unit into position. Be careful not to level. Level should kink the water supply line or entangle the cord. be placed along top edge and side edge 3. Re-check the leveling, from front to back and side to as shown. side. Make any necessary adjustments.
QUICK START GUIDE u-line.com 8. Starting at the corners and working inward, push door 1. Remove top hinge screw pin gasket into place on door. with Phillips head screwdriver. Remove door by tilting forward and lifting off bottom hinge pin. 9. Place door on bottom hinge pin and install upper hinge screw. CRECENT ICE MAKERS AND ADA15IM 1. Fully open door/drawer. 2. Starting at corner, pull 2. Pull door gasket out of groove gasket away from door/ (top edge of door only). Start in drawer.
QUICK START GUIDE 6. Secure integrated panel to door/drawer u-line.com 11.Remove clamps from door/drawer. Bar Clamp using clamps. A NOTICE robust tape may also be used. U-Line If panel requires additional adjustment after recommends the use removing clamps, slightly loosen each screw and of bar clamps to adjust panel as necessary. Tighten screws upon Door/Drawer completion. secure the panel to the door/drawer. If using tape, be Wood Panel 12.
QUICK START GUIDE u-line.com Ice During periods of limited use or high ambient ICE MAKER OPERATION Gently shake the bucket to break apart cubes. If not using When the ice bucket is full, the ice making mechanism will the ice maker regularly, empty the ice bucket periodically shut off. However, the refrigeration system will continue to ensure fresh cubes. temperatures, it is common for cubes to fuse together. to cool and maintain the ice supply. It is normal for cubes to appear cloudy.
QUICK START GUIDE u-line.com option repair or replace any part of the sealed system; under the terms of this warranty as a result of that and (2) for all Marine, RV and Domestic U-Line exposure. U-Line product may not be subjected to products sold and serviced in the United States temperatures below 40°F without following the (including Alaska and Hawaii) and Canada, U-Line shall winterization and vacation shutdown procedures in the be responsible for the labor costs incurred in user guide.
QUICK START GUIDE u-line.com the product or from any other cause whatsoever, apply to cosmetic damages. A proof of purchase may whether based on warranty (express or implied) or be required. otherwise based on contract, tort or any other theory of liability. 4.
QUICK START GUIDE u-line.com 7. If any applicable national law provides for a minimum mandatory warranty period that is longer than the aforementioned period of two years from the date of purchase, such longer period shall apply. 8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH ARE DISCLAIMED.