Service manual

15. Not Freezing (compressor and fan not operating)
Cause Remedy
No electrical power to unit Make sure unit is plugged in and outlet
has power
Rocker switch defective or wired Make sure switch is wired correctly and
incorrectly set in “ICE” position
IF UNIT HAS P-60 PUMP
Cause Remedy
Drain tube kinked or obstructed Clear the tubing
j
Bad pump. Diagnose by bypassing Change pump
k
the pump. Pull both pink wires from
control board and jump the two
terminals together. If unit starts up,
then the pump is bad.
Open wire in wiring harness Trace defective wire and repair or
replace parts accordingly
j: If water cannot drain from pump, unit will shut down due to safety design of pump.
k: Jumping the two terminals on control board together with a jumper wire will eliminate
pump from the circuit.
16. Water Leak Under Unit
Cause Remedy
Incoming water supply line leaking Make sure brass connection is screwed
tight to valve and threaded correctly
Fill tube leaking Tighten fill tube connection to water line
Bin spout is cracked or mis-formed Unit not repairable. Contact U-Line
tech line for assistance.
17. Water In Ice Bin
Cause Remedy
Bin drain kinked or restricted Clear drain of obstruction or kink
External drain is restricted Clear restriction
Bad pump Replace pump
18. Water Will Not Stop Filling
Cause Remedy
Water solenoid stuck in open position Replace water valve
Open relay on control board Replace control board
NOTE: A defective relay on control board would cause both the water valve and reversing
valve to stay open, therefore, this failure would not allow the unit to freeze.
19. Unit Noisy
Cause Remedy
Fan motor not secured to bracket Tighten motor
Fan blade bent Realign or replace blade
Vibration from refrigerant lines Secure tubing
Obstruction in fan blade Remove obstruction
REPLACEMENT PARTS: Use only genuine U-Line replacement parts. The use of non
U-Line parts can reduce ice rate, cause water to overflow from ice maker mold, dam-
age the unit, and may void the warranty.