Service manual

10. Low (or no) Ice Production
Cause Remedy
Dirty condensing coil (Control board Clean condensing coil
light shows rapid flash)
Stalled condenser fan blade (Control Free up the blade or replace fan motor
board light shows a rapid flash)
No water in water trough Install stand pipe securely in trough
Bypass valve stuck in open position Replace bypass valve
Ice forms on a portion of evaporator grid Check unit for system undercharge or leak
NOTE: See chart of suction pressures
in manual.
11. Poor Ice Quality (soft or unclear cubes)
Cause Remedy
Poor incoming water quality Consult a plumber
Deposit build-up on evaporator grid Run the unit through a clean cycle. Use
only U-Line Ice Machine Cleaner
Water splashing on cubes Adjust water flow above evaporator
12. Unit Not Freezing (compressor and fan operating)
Cause Remedy
Little or no cooling Check sealed system for leak or restriction
Bypass valve stuck in open position NOTE: See chart of suction pressures
in manual.
Replace bypass valve
13. Unit Produces Shallow or Incomplete Cubes or the Ice Fill Pattern on the Grid is
Incomplete
Cause Remedy
Low water level Check that standpipe is fully seated
inside water trough
Low water pressure Check water pressure into water valve
(pressure should be 20 to 120 psi).
Unit is not level Level unit to assure even water flow
h
Operating unit without back or Install back or front panel
i
front panel
Bad thermister Replace thermister
Bad control board Replace control board
h: uneven water flow will reduce ice rate and cause incomplete cubes. See Leveling
Instructions in manual.
i: the unit will harvest ice according to temperatures of tubing at condensing coil.
Increased air flow will give the thermister false information. This info could cause the
ice to eject prematurely.
14. Not Freezing Compressor Not Running / Fan Operating
Cause Remedy
Bad overload (open) Replace overload
Bad compressor Replace compressor
Service and Parts Manual
24