Service manual

5. Low Ice Production
Cause Remedy
High ambient temperatures around unit Lower ice rate is normal with high
ambient temperatures
Deposit build-up on evaporator grid Run the unit through a clean cycle. Use
only U-Line Ice Machine Cleaner
Ice thickness dial set incorrectly Adjust ice thickness dial accordingly
Dirty condenser coil Clean condenser coil
NOTE: Light on control board will indicate if condenser is too dirty. A rapid flash of light
indicates high heat conditions which could be caused by either an inadequate air flow or
a dirty condenser.
6. Will Not Eject Ice (Water Frozen)
Cause Remedy
Bin thermostat set incorrectly Set bin thermostat at 10:00 position
Wiring plug off of bypass valve coil Re-install plug
Defective bypass valve Replace bypass valve
Deposit build-up on evaporator grid Run unit through the clean cycle. Use
only U-Line Ice Machine Cleaner
e
e: If scale or mineral deposits accumulate on grid, cubes will not fall freely.
7. Ice Is Slow To Release From Evaporator
Cause Remedy
Deposit build-up on evaporator grid Run unit through the clean cycle. Use
only U-Line Ice Machine Cleaner.
Unit not level Level unit for even water flow
f
f: Uneven water flow will reduce ice rate and cause water to spill in ice bin.
8. Will Not Fill With Water
Cause Remedy
No stand pipe in water trough Install stand pipe
Water valve is defective Replace valve
Water solenoid unplugged Repair wiring defect
or wire to solenoid has internal break
9. Continuous Ice Production
Cause Remedy
Bin thermostat set too cold Set bin thermostat to the 10:00 position
Bin thermostat sensing bulb out Insert bulb inside aluminum sensor tube
of alignment
Bin thermostat stuck in closed position Replace bin thermostat
Ice slab too thick Set ice thickness adjustment dial to a
lower setting
g
g: If cubes release from grid and are too thick, cubes might not make contact with
sensor tube (inside of bin) therefore bin thermostat would never be satisfied.
23