NEVER attempt to repair or perform maintenance on the unit until the main
electrical power has been disconnected.
1. Unit Does Not Operate (With drain pump; light on control board is not illuminated)
Cause Remedy
■ No electrical power to the unit ■ Make sure unit is plugged in and outlet
has power
■ Rocker switch set incorrectly ■ Check switch wiring. Set to “ICE”
■ Drain tube is kinked or obstructed ■ Clear the tubing
a
■ Bad pump. Diagnose by bypassing ■ Change pump
b
the pump. Pull both pink wires from
control board and jump the two
terminals together. If unit starts up,
then the pump is bad.
a: If water cannot drain from pump, unit will shut down due to safety design of pump.
b: Jumping the two terminals on control board together with a jumper wire will eliminate
pump from the circuit.
2. Unit Does Not Operate (Without drain pump; light on control board is not illuminated)
Cause Remedy
■ No power to unit ■ Jumper plug off power cord
3. Unit Does Not Operate And Light On Control Board is Illuminated
Cause Remedy
■ Bad bin thermostat ■ Replace bin thermostat
c
■ Bin thermostat set incorrectly ■ Set bin thermostat at the 10:00 position
c: The unit is falsely sensing a full bin.
4. No Ice Production
Cause Remedy
■ No water supplied to unit ■ Check that water is connected and
turned on
■ Stand pipe not inserted in water trough ■ Insert stand pipe securely into water
trough
■ Re-circulating pump is defective ■ Replace re-circulating pump
! !
TROUBLESHOOTING