The ice thickness control is factory set to maintain
an ice bridge of 1/16" to 1/8". A dimple in each
cube is normal. This size cube will break apart from
the slab easily as it falls into the ice bin. A fuller
cube, with less of a dimple, can be achieved by
adjusting the cube size. This will result in a thicker
ice bridge. As the ice bridge becomes thicker, the
tendency for the cubes to stay together as a slab
increases.
If an adjustment is needed, perform the following steps:
Do not touch electrical wires. Disconnect power to the ice maker before
making any ice thickness adjustments.
1. Disconnect power from the unit.
2. Remove front access panel (2 screws).
3. Locate the ice thickness adjustment dial on the control board (See below).
NOTE
Ice thickness adjustment dial should be turned only one increment at a time.
Allow the unit to stabilize for 24 hour hours before making further adjust-
ments.
4. Turn ice thickness adjustment dial clockwise for a thicker ice bridge or counterclock-
wise for a thinner ice bridge.
5. Reinstall front access panel.
6. Reconnect power.
UL318A
DIAL IS FACTORY
SET TO +1
ICE THICKNESS
ADJUSTMENT
DIAL
0
1
2
3
4
5
-5
-4
-3
-2
-1
0
1
2
3
4
5
-5
-4
-
3
-2
-1
! !
ICE BRIDGE SHOULD BE
1/16 - 1/8 INCH THICK
A DIMPLE IN EACH
CUBE CELL IS NORMAL
UL250
ICE THICKNESS ADJUSTMENT