Service manual
13
Automatic Clean Cycle
To maintain operational efficiency, clean unit every six months (depending on water condi-
tions more or less frequent cleaning may be necessary). If the ice maker requires more
frequent cleaning, consult a qualified plumber to test the water quality and recommend
appropriate treatment. Use only U-Line Ice Machine Cleaner (part number 41978).
Use only U-Line Ice Machine Cleaner (part number 41978). It is a violation of
Federal law to use this solution in a manner inconsistent with its labeling. Use
of any other cleaner can ruin the finish of the evaporator and will void the war-
ranty. Read and understand all labels printed on the package before use. Ice
machine cleaner is used to remove Lime scale and other mineral deposits.
Refer to the following steps for mineral deposit removal.
1. Set the cycle selector switch (located in the center of the
grille) to OFF and allow the ice to melt off of the evaporator.
2. Remove all ice from the storage bin.
3. Remove inside front cover by gently pulling away from side-
wall. See Figure A.
4. Remove the overflow tube by lifting it up while using a slight
back and forth motion to loosen it from the drain hole. See
Figure B. The water in the reservoir will flow down the drain.
5. Replace the overflow tube after all the water has been
drained from the reservoir.
6. Move the cycle selector switch to the CLN position.
7. When water begins to flow over the evaporator, (approxi-
mately 3 minutes) add one packet of U-Line Ice Machine
Cleaner to the reservoir.
8. Reinstall inside front cover.
9. When the self cleaning process stops (approximately 45
minutes). At this time, it may be desirable to clean the
storage bin. (See INTERIOR STORAGE BIN CLEANING)
10.Move the cycle selector switch to the ICE position to
resume ice production.
Interior Storage Bin Cleaning
1. Disconnect power from the ice maker.
2. Remove any ice from the storage bin.
3. Wipe down the storage bin with a solution of non-abrasive mild soap or detergent and
warm water. Rinse with clean water. Sanitize the bin with a solution of 1 tablespoon
of bleach and 1 gallon of water. Rinse thoroughly with clean water.
4. Check that all drain connections are in place.
5. Reconnect power to the unit.
!
AUTOMATIC CLEAN CYCLE INSTRUCTIONS
UL208
FRONT COVER
U•LINE
U
UL209
OVERFLOW
Figure A
Figure B