Use & Care Manual
CLR2160, CLRCO2175 21
4. Check that the clamps and hose connections are tight at 
the following areas (see 
Figure 36
):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
Figure 36
5. Place a suitable container beneath the pump’s discharge 
tube. (The bucket must be able to hold a minimum of 
one gallon.)
6. Plug the ice maker power cord into a properly 
grounded, polarized electrical outlet.
7. Place the unit into OFF mode by holding power key for 
10 seconds. Not doing this will cause the unit to start 
the fill cycle which will run for 3 minutes.
8. Verify pump operation by pouring one gallon of water 
into the ice storage bin of the ice maker. The pump 
should energize and pump the water into the container.
9. At this time, verify that all tube and clamp connections 
are tight and leak-free. 
10. Unplug unit power cord from electrical outlet.
11. Reinstall back panel.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have 
not purchased a CLR2160 or CLRCO2175 with factory-
installed pump, we strongly recommend the use of the 
U-Line P60 drain pump. The U-Line P60 drain pump is 
available through your Dealer, with complete installation 
instructions. If a pump other than the U-Line P60 drain 
pump is to be used, it must meet the following 
specifications:
•
It must be UL listed and have a UL listed, 120 VAC, 
3-wire grounded power cord.
•
It must have overall maximum outside dimensions of 
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 1.5 gallons per 
minute at 10 feet of lift.
• It must have a sealed sump which does not allow water 
leakage in the case of a power outage, restricted drain 
or pump failure.
• It must have a check valve in the discharge line to 
prevent waste water return to the pump.
• It must have an overflow protection control which will 
shut off power to the ice maker in the event of a pump 
failure.
• It must have an operating temperature range of 50°F 
to 110°F (10°C to 40°C).
IMPORTANTIMPORTANT
In the event of a power outage, restricted drain or 
pump failure, the failure to use the U-Line P60 drain 
pump or a pump with the above listed 
specifications, could result in substantial water 
leakage and pooling with severe and costly water 
damage and related consequential damages and 
harm.
Figure 37
Figure 38
Back View Side View
BB
A
CC
ULIN_0575_A
Cold 
Water 
Hot 
Water 
Waste 
Waste 
Shut-Off 
Valve 
Stand Pipe
P60 Pump Required
ULIN_0571a_A
Air Gap 
(Optional Hook-Up) 
Cold 
Water 
Hot 
Water 
Waste 
Shut-Off 
Valve 
Disposal Assembly
P60 Pump Required
ULIN_0572a_A