- USER MANUAL - CLR2060
37
Problem Possible Cause Remedy
Unit runs but Scale and mineral  Clean unit. See 
produces very buildup in unit. MAINTENANCE.
little ice.
Inadequate airflow at  Remove items blocking 
(continued)
the front of the unit. airflow.
Ice is slow to  Ice-making system  Run unit through 
release or does  is dirty. automatic clean cycle. 
not release from  See MAINTENANCE.
the evaporator.
Unit is not level. See LEVELING THE 
UNIT.
Low air temperature  Surrounding air 
around unit. temperature must be 
at least 50°F (10°C).
Poor ice quality. Poor incoming water  Consult a qualified 
(soft or unclear) quality. plumber to test the 
water quality and 
recommend appropriate 
treatment.
Ice-making system is  Run unit through 
dirty. automatic clean cycle. 
See MAINTENANCE.
Unit produces  Low water level. Check to see that 
shallow or  overflow tube is fully 
incomplete cubes,  seated.
or the ice fill 
pattern on the  Hot incoming water. Connect the unit to a 
evaporator is  cold water supply. 
incomplete. See INSTALLATION.
Incorrect incoming  Water pressure must 
water pressure. be 20-120 psi.
Unit is not level. See LEVELING THE 
UNIT.
Body_UM.qxd 12/17/04 9:16 AM Page 37