User Guide
CLR2060 — Clear Ice Maker
www.U-LineService.com 6 02/2005
™
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 
60 Hz, 15A circuit (normal household current). See 
Electrical Specifications on Page 16.
Water Supply
The unit requires a 1/4-inch OD water supply line and a 
shut-off valve. For more information see Page 15.
Drain
The unit’s generous 7-inch drain connection height 
extends the distance the unit can be located from a 
gravity drain. For more information see Page 12.
IMPORTANT
Drain can NOT be located directly below unit. Unit has a 
solid base that will not allow unit to drain below itself.
Environmental Requirements
The surrounding air temperature must be at least 50°F 
(10°C) but must not exceed 110°F (40°C). High ambient 
temperature ranges and warmer water supply will cause 
reduced ice production. Black and White units may be 
installed outdoors in a covered area. Stainless Steel 
CLR2060 units are deemed suitable for outdoor use by UL. 
The unit must not be located near heat-generating 
equipment or in direct sunlight.
Side-By-Side Installation 
Instructions
For a complete refreshment center, install your CLR2060 
Clear Ice Maker beside a U-line Refrigerator, Combo, or 
Wine Captain Model (see Figure 11 for typical cut-out). 
Note that each Side-By-Side Installation will be different.
• Cut-out width for a side-by-side installation is the total 
of the widths listed under Cut-Out Dimensions in each 
unit’s Installation Guide. 
For example:
Placing a CLR2060 Clear Ice Maker next to a 2015R 
Refrigerator would require a cut-out width of:
15-3/16" + 15-3/16" = 30-3/8"
Placing a CLR2060 Clear Ice Maker next to a 2075R 
Refrigerator would require a cut-out width of:
15-3/16" + 24-3/16" = 39-3/8"
•
No trim kit is required. However, 1/4-inch space needs to 
be maintained 
between the units to ensure 
unobstructed door swing.
• Units must operate from separate, properly grounded 
electrical receptacles placed according to each unit’s 
Electrical Specifications.
Acceptable
Location
Preferred
Location
for CLR2060
Receptacle
1"
7"
24"
34-1/4"
to
35-1/8"
1/4" Space
Between Appliances
Figure 11
Typical Side-By-Side Cut-Out