CAUTION
In the event of a power outage, restricted drain or pump 
failure, the failure to use the U-Line P60 drain pump or a 
pump with the above listed specifications, could result in 
substantial water leakage and pooling with severe and 
costly water damage and related consequential damages 
and harm.
Water Supply Connection
When connecting the water supply, follow these 
guidelines:
• Review the local plumbing codes before you install the 
unit.
• Connect to the cold water supply.
• The water pressure should be between 20 and 120 psi.
• Install a shut-off valve in the 1/4 inch OD water supply 
line.
• Connect sufficient tubing to the unit so that tubing 
may be looped, allowing the unit to be removed for 
cleaning and servicing (see Figure 40). However, make 
certain that the tubing is not pinched or damaged 
during installation.
• U-Line recommends the use of copper tubing for 
installation.
To connect to water supply:
1. Install the 1/4 inch OD copper water line from the 
main water source (see Figure 37).
2. Locate the compression fitting and ferrule packed with 
this guide. Slide the compression fitting and ferrule 
over the 1/4-inch OD water supply line. Do not use 
thread sealing compound or tape. Using two wrenches, 
tighten the compression fitting on the supply line (see 
Figure 38
).
3. Carefully bend the water supply line into position and 
connect the line to the solenoid valve (see 
Figure 39
). 
Avoid kinking the water supply line.
IMPORTANT
Normal operation creates some vibration. A water supply 
line contacting cabinet wall may cause excessive noise 
during operation or damage to the line.
4. For recessed installations, allow extra water supply line 
length to provide slack for easy removal from the 
recessed area (see 
Figure 40
). This will also safeguard 
against kinking the line. 
5. Go on to 
7 Prepare Power Supply
Figure 38Figure 37
Water
Connection
Figure 40Figure 39
Power
Cord
Water Line