To check and test hose connections:
1. Make certain the unit is not plugged into an electrical 
outlet.
2. Carefully push the power cord grommet through the 
hole in the back panel (see 
Figure 35
).
3. Remove 12 screws and back panel.
WARNING
Back panel serves as a guard. DO NOT put your 
hands inside the ice maker cabinet or attempt to 
touch any components except the discharge tube 
during testing. Failure to follow this warning 
could result in serious personal injury or death.
4. Check that the clamps and hose connections are tight at 
the following areas (see 
Figure 36
):
• Discharge tube (A)
• Drain tube (B)
• Vent tube (C)
5. Place a suitable container beneath the pump’s discharge 
tube. (The bucket must be able to hold a minimum of 
one gallon.)
6. Plug the ice maker power cord into a properly 
grounded, polarized electrical outlet.
7. Verify pump operation by pouring one gallon of water 
into the ice storage bin of the ice maker. The pump 
should energize and pump the water into the container.
8. At this time, verify that all tube and clamp connections 
are tight and leak free. 
9. Unplug unit power cord from electrical outlet.
10. Reinstall back panel.
To connect to drain:
1. Attach the 5/8-inch ID drain connection on the back of 
the unit to a 5/8-inch OD rigid tube, using a worm 
clamp.
2. Attach the other end of the rigid tube to your 5/8-inch 
ID drain line with a worm clamp.
3. Insulate the drain line, if necessary to prevent 
condensation. Go on to Water Supply Connection.
Locally-Installed Drain Pump
If a gravity drain connection is not possible, and you have 
not purchased the CLR2060 with factory-installed pump, 
we strongly recommend the use of the U-Line P60 drain 
pump. The U-Line P60 drain pump is available through 
your Dealer, or direct from U-Line with complete 
installation instructions. If a pump other than the U-Line 
P60 drain pump is to be used, it must meet the following 
specifications:
•
It must be UL listed and have a UL listed, 120 VAC, 
3-wire grounded power cord.
•
It must have overall maximum outside dimensions of 
8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• It must have a minimum flow rate of 15 gallons per 
hour at 10 feet of lift.
• It must have a sealed sump which does not allow water 
leakage in the case of a power outage, restricted drain 
or pump failure.
• It must have a check valve in the discharge line to 
prevent waste water return to the pump.
• It must have an overflow protection control which will 
shut off power to the ice maker in the event of a pump 
failure.
• It must have an operating temperature range of 50°F 
to 110°F (10°C to 40°C).
Power
Cord
Grommet
Drain
Fitting
Back
Panel
Screws
Water
Connection
Figure 35
Back View Side View
BB
A
C
C
Figure 36