User Guide
CLR2060 — Clear Ice Maker
02/2005 13 www.U-LineService.com
™
If using a Gravity Drain:
1. Attach the 5/8-inch ID drain connection on the back of 
the unit to a 5/8-inch OD rigid tube, using a worm 
clamp.
2. Attach the other end of the rigid tube to your 5/8-inch 
ID drain line with a worm clamp.
3. Insulate the drain line, if necessary to prevent 
condensation. Go on to Water Supply Connection.
Factory-Installed Drain Pump
If your drain line will run up to a stand pipe, disposal 
assembly or spigot assembly or does not otherwise meet 
the requirements for a Gravity Drain, you may have 
ordered the CLR2060 with a U-Line P60 Drain Pump. See 
Figures 32, 33 and 34 for typical installations requiring a 
Drain Pump. If you need to install a P60 Drain Pump into 
your unit, see Locally-Installed Drain Pump on Page 14.
IMPORTANT
Before installing your U-Line CLR2060 with Factory- 
Installed U-Line P60 Pump, it is extremely important to 
check and test all hose connections at the drain pump. 
There is a possibility that hose connections may have 
loosened during shipment.
WARNING
To prevent accidental electrocution, make certain 
that the floor surfaces surrounding the unit are 
dry whenever power is removed from, or applied 
to, the unit.
Waste
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Figure 31
Gravity Drain
Waste
Cold
Water
Hot
Water
Waste
Shut-Off
Valve
Figure 32
Stand Pipe
Cold
Water
Hot
Water
Waste
Air Gap
(Optional Hook-Up)
Shut-Off
Valve
Figure 33
Disposal Assembly
Waste
Cold
Water
Shut-Off
Valve
Hot
Water
Air Gap
(Optional Hook-Up)
Figure 34