Re-Select Model allows the units model information to be 
modified. Changing the units model completely 
reprograms available zones, relay assignments, DC output 
assignments etc. 
To access Re-Select Model
1. Press   to select “Re-Select Model”.
2. Press .
To change model setting
3. Press   to select “Model=” and press  . “Model” will 
begin to flash. 
4. Press   or   to scroll through each available model.
5. Press   to confirm. While processing, the   will 
momentarily change to    .
To exit Re-Select Model, press   to select “Return to 
Menu” and press   to confirm. (Power cycling unit is 
recommended after re-selecting model.)
Factory Wi Fi
The Factory Wi-Fi option is only used in manufacturing 
and should always be OFF.
1. Press   to select “Factory Wi Fi”.
2. Press .
3. Press   or   select “OFF”.
To exit the Factory Wi Fi menu press   to select “Return 
to Menu” and press   to confirm outputs.
Set Points
The Set points menu contains options to modify both the 
Zone and Evap set points. Changes to the zone set point 
will be reflected on the main screen. Changes to the evap 
set point alter the temperature the evaporator needs to 
meet during a defrost cycle.
To access Set Points
1. Press   to select “Set Points”.
2. Press .
3. Press   and   to scroll through available set points.
To change set points
4. Press  , the selected set point will begin to flash.
5. Press   or   to modify the value.
6. Press   to confirm setting.
To exit the Set Points menu, press   to select “Return to 
Menu” and press   to confirm.
Fan Delay (excludes ZWC)
Up
Select
Down
RETURN TO MENU
FACTORY WiFi
OFF
Up
Select
Down
RETURN TO MENU
SET POINTS
ZONE = 3°C
EVAP = 5°C
Up
Select
Down
RETURN TO MENU
FAN DELAY
FAN DELAY ON = 1
FAN DELAY OFF = 2
*