User Guide & Service Guide
USER GUIDE
 Control Operation - Service 4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
5. Press .
6. Press   and   to scroll through each relay and DC 
output.
7. Press   to toggle.
To exit the Relay Toggle menu press   to select “Return 
to Menu” and press   to confirm.
Input Status
Input status displays the current state of each available 
input.
To access Input Status
1. Press   to select “Input Status”.
2. Press .
3. Press   and   to scroll through available 
information.
To exit the Input Status menu press   to select “Return 
to Menu” and press   to confirm outputs.
Outputs
Outputs is used to monitor the state of DC outputs. 
To access Outputs
1. Press   to select “Outputs”.
2. Press .
3. Press   and   to scroll through available 
information.
To exit the Input Status menu, press   to select “Return 
to Menu” and press   to confirm.
Offsets
NOTICE
Do not make an adjustment to this without first 
contacting the tech line: (800) 779-2955.
ID Description State
Left Door Left (top) Door Switch Open - Closed
Right Door Right (bottom) Door Switch
(excludes ZWC)
Open - Closed
Up
Select
Down
RETURN TO MENU
INPUT STATUS
DOOR OPEN
IN2 OPEN
ID Description Value
L Evap Fan Left (top) Evaporator 
Fan (excludes ZWC)
On - Off
R Evap Fan Right (bottom) 
Evaporator Fan 
(excludes ZWC)
On - Off
Condenser Fan Condenser Fan On - Off
L Light Left (top) Light Off - Low - Med - High
R Light Right (bottom) Light Off - Low - Med - High
Up
Select
Down
RETURN TO MENU
OUTPUTS
EVAP FAN=0%
CONDENSER FAN=0%
Up
Select
Down
RETURN TO MENU
OFFSETS
ZONE = 1°F
EVAP = 1°F
Can be displayed in Celsius
56