User Guide & Service Manual

USER GUIDE
 Troubleshooting - Extended 6
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
THERMISTORS
Thermistors are used for various temperature readings. 
Thermistors provide reliable temperature readings using a 
resistance which varies based on surrounding 
temperatures. If a faulty thermistor is suspected it may 
be tested using an accurate ohmmeter. In an ice water 
bath (32°F) resistance should measure 16.1 kilohms.
5K OHMS @ 77°
16.1K OHMS - 32°F ambient
THERMISTOR FAILURE
Limp Mode Data Table
Zone Thermistor
If the zone thermistor fails, the unit will continue to 
operate in a timed limp mode which varies by model. The 
unit will otherwise operate normally. The error will be 
displayed in the error log.
Evaporator Thermistor
If the evaporator thermistor fails, the unit will rely on a 
preset defrost time during defrost cycles. The unit will 
otherwise operate normally. Evaporator thermistor errors 
will be displayed in the error log.
Always assure that all thermistor connections are clean 
and dry. Whenever opening a thermistor connection be 
sure to apply a fresh dab of die electric grease.
REED SWITCH
A reed switch is used to monitor door state. When the 
door is closed magnetic force pulls the reed to its contact 
and closes the circuit which turns the light and display off. 
When the door is open the reed pulls away from the 
contact and opens the circuit. If the door is left open for 
longer than 5 minutes, the switch will trigger an error code 
and set an audible warning.
Mode ON OFF
Beverage/Drinks 10 min. 45 min.
Market/Fresh 10 min. 45 min.
Root 5 min. 90 min.
Pantry 10 min. 45 min.
Deli 10 min. 45 min.
Magnet Close To Switch
(Door Closed)
(Switch Closed)
Magnet Away From Switch
(Door Open)
(Switch Open)
46