User Manual
Table Of Contents
- Bluetooth® RF Transceiver 750-644
- 1 Important Comments
- 2 I/O Modules
- 2.1 Special Modules
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1.1.1 View
- 2.1.1.2 Description
- 2.1.1.3 Indicators
- 2.1.1.4 Schematic Diagram
- 2.1.1.5 Technical Data
- 2.1.1.6 Function Description
- 2.1.1.7 Operating Modes
- 2.1.1.8 Process Image
- 2.1.1.8.1 Process Data Communication
- 2.1.1.8.2 Mailbox Communication
- 2.1.1.8.3 Register Communication
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1 Special Modules
- 3 Configuration of a Bluetooth® Piconet
- 4 Tools for Configuring and Operating
- 4.1 Configuring and Operating with WAGO-I/O-CHECK
- 4.2 Configuring the Bluetooth® Module 750-644
- 5 Fieldbus-specific Additions
- 6 Appendix
- 6.1 Mailbox Commands
- 6.2 Return Values of Mailbox Commands
- 6.3 Mailbox Command References
- 6.3.1 General Commands
- 6.3.2 Block Transfer
- 6.3.3 Maintenance and Firmware
- 6.3.4 Process Image
- 6.3.5 Device Configuration
- 6.3.5.1 Read the Local Device Name(GetLocalDeviceName, 0x40)
- 6.3.5.2 Write the Local Device Name (SetLocalDeviceName, 0x41)
- 6.3.5.3 Read Local MAC ID (GetLocalMacID, 0x42)
- 6.3.5.4 Read Local IP Address (GetLocalIPAddress, 0x43)
- 6.3.5.5 Set Local IP Address (SetLocalIPAddress, 0x44)
- 6.3.5.6 Read Local Subnet Mask (GetLocalSubnetMask, 0x45)
- 6.3.5.7 Set Local Subnet Mask (SetLocalSubnetMask, 0x46)
- 6.3.5.8 Read Local WAGO Device Class (GetLocalDeviceClass, 0x47)
- 6.3.5.9 Write Local Device Class (SetLocalDeviceClass, 0x48)
- 6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
- 6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
- 6.3.5.12 Read Local Encryption Mode (GetLocalEncryptionMode, 0x4D)
- 6.3.5.13 Set Local Encryption Mode (SetLocalEncryptionMode, 0x4E)
- 6.3.5.14 Read Local Authentication Mode (GetLocalAuthenticationMode, 0x4F)
- 6.3.5.15 Set Local Authentication Mode (SetLocalAuthenticationMode, 0x50)
- 6.3.5.16 Read Local Bluetooth® Password (GetLocalPassphrase, 0x51)
- 6.3.5.17 Write Local Bluetooth® Password (SetLocalPassphrase, 0x52)
- 6.3.5.18 Delete Locally Saved Authorization (EraseLocalAuthentication, 0x53)
- 6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen, 0x54)
- 6.3.5.20 Read Role of the Local Device (GetLocalDeviceRole, 0x55)
- 6.3.5.21 Set Role of the Local Device (SetLocalDeviceRole, 0x56)
- 6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
- 6.3.5.23 Search for Remote Bluetooth® Device in the Wireless Network (ScanRemoteDevices, 0x80)
- 6.3.5.24 Read MAC-ID of a Remote Bluetooth® Device (GetRemoteDeviceMacID, 0x81)
- 6.3.5.25 Read Device Name of a Remote Bluetooth® Device (GetRemoteDeviceName, 0x82)
- 6.3.5.26 Enter External Device in the Table of Authorized Devices (AllowRemoteDevice, 0x83)
- 6.3.5.27 Read Back External Device from the Table of Authorized Devices (GetAllowedRemoteDevices, 0x84)
- 6.3.5.28 Grant Access Authorization for a Device (BindRemoteDevice, 0x85)
- 6.3.5.29 Delete Access Authorization for a Device (UnbindRemoteDevice, 0x86)
- 6.3.5.30 Read Access Authorization for Remote Devices (GetBoundRemoteDevices, 0x87)
- 6.3.5.31 Read Back the QoS Settings (GetConnectionQoS, 0x88)
- 6.3.5.32 Set the QoS Settings (SetConnectionQoS, 0x89)
- 6.3.5.33 Read Back Time Settings - Between Two Attempts to Establish a Connection (GetReconnectionTimePeriod, 0x8A)
- 6.3.5.34 Set Time Settings - Between Two Attempts to Establish a Connection (SetReconnectionTimePeriod, 0x8B)
- 6.3.5.35 Read the User-Friendly Name of an Authorized Device (GetUserfriendlyName, 0x8C)
- 6.3.5.36 Write the User-Friendly Name of an Authorized Device (SetUserfriendlyName, 0x8D)
- 6.3.6 Diagnostics
- 6.3.6.1 Read Status of the Local Bus Module (GetLocalDeviceStatus, 0xD0)
- 6.3.6.2 Read Status of the Wireless Network (GetNetworkStatus, 0xD1)
- 6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
- 6.3.6.4 Read Connection Quality (GetLinkQuality, 0xD5)
- 6.3.6.5 Read Signal Strength for a Connection (GetLinkSignalStrength, 0xD7)
- 6.3.6.6 Read Available Hopping Channels (GetAvailableChannelMap, 0xD8)
- 6.3.6.7 Set an LED (SetLED, 0xD9)
- 6.3.6.8 Mirror Mailbox for Test Purposes (MirrorMailboxCommand, 0xDA)
- 6.3.6.9 Read the Operating Time of the Module (GetLocalUpTime, 0xDB)
- 6.4 Extended Register Structure (Configuration Block)
- 6.5 Example Configurations using WAGO-I/O-CHECK
- 6.5.1 Startup with the Bluetooth® Parameterization Dialog
- 6.5.2 Startup using Mailbox Commands in the Process Data Dialog
- 6.5.2.1 Network Structure
- 6.5.2.2 Starting up the Bluetooth® Modules
- 6.5.2.2.1 Switch the Mailbox on
- 6.5.2.2.2 Reset Modules to Factory Default
- 6.5.2.2.3 Determining the Master
- 6.5.2.2.4 Querying the MAC Address
- 6.5.2.2.5 Loading the MAC Addresses of the Slaves into the Device List of the Master
- 6.5.2.2.6 Loading the MAC Address of the Master into the Device Lists of the Slaves
- 6.5.2.2.7 Binding the Slaves in the Master
- 6.5.2.2.8 Binding the Master in the Slaves
- 6.5.2.2.9 Setting the Communication Mode for Master and Slaves
- 6.5.2.3 Testing the Process Data Exchange
- Glossary
Tools for Configuring and Operating • 81
Configuring the Bluetooth® Module 750-644
WAGO-I/O-SYSTEM 750
I/O Modules
4.2.6 Assigning Slave Process Data to Slots in the Master
Choose Settings in the context menu of the selected module (node view or
navigation) to open the parameterization dialog. Click on PI Mapping in the
navigation area.
The master only considers parts of the individual slave process images. Select
the size of these parts (cutoff) using the slide control. As an alternative, you
can enter the number of bytes in the entry field to the side.
Please note: Only up to 7 real-time devices or up to 6 ad hoc devices can be
active at the same time. These are the only devices you can bind by selecting
Bind - "Yes" in the PI Mapping configuration area for communication. If you
bind all 13 devices and each of the 13 slots is occupied, only the first six real-
time devices and the first ad hoc device will be free for communication.
4.2.7 Diagnostics
Choose Settings in the context menu of the selected module (node view or
navigation) to open the parameterization dialog. Click on Diagnostics in the
navigation area.
On this page, you will see status reports for the Bluetooth
®
device, the trans-
mission channel and network displayed. Click on the [Start Diagnostics] but-
ton to constantly query current values. Click on [Stop Diagnostics] to display
the most recently received status with no further updating.
A click on the right column of the table opens a dialog window in which you
can query status information for individual slots or all existing connections by
selecting an object group and clicking [Execute].
Additional Information
An example configuration using WAGO-I/O-CHECK can be found in Ap-
pendix 6.5.