User Manual
Table Of Contents
- Bluetooth® RF Transceiver 750-644
- 1 Important Comments
- 2 I/O Modules
- 2.1 Special Modules
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1.1.1 View
- 2.1.1.2 Description
- 2.1.1.3 Indicators
- 2.1.1.4 Schematic Diagram
- 2.1.1.5 Technical Data
- 2.1.1.6 Function Description
- 2.1.1.7 Operating Modes
- 2.1.1.8 Process Image
- 2.1.1.8.1 Process Data Communication
- 2.1.1.8.2 Mailbox Communication
- 2.1.1.8.3 Register Communication
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1 Special Modules
- 3 Configuration of a Bluetooth® Piconet
- 4 Tools for Configuring and Operating
- 4.1 Configuring and Operating with WAGO-I/O-CHECK
- 4.2 Configuring the Bluetooth® Module 750-644
- 5 Fieldbus-specific Additions
- 6 Appendix
- 6.1 Mailbox Commands
- 6.2 Return Values of Mailbox Commands
- 6.3 Mailbox Command References
- 6.3.1 General Commands
- 6.3.2 Block Transfer
- 6.3.3 Maintenance and Firmware
- 6.3.4 Process Image
- 6.3.5 Device Configuration
- 6.3.5.1 Read the Local Device Name(GetLocalDeviceName, 0x40)
- 6.3.5.2 Write the Local Device Name (SetLocalDeviceName, 0x41)
- 6.3.5.3 Read Local MAC ID (GetLocalMacID, 0x42)
- 6.3.5.4 Read Local IP Address (GetLocalIPAddress, 0x43)
- 6.3.5.5 Set Local IP Address (SetLocalIPAddress, 0x44)
- 6.3.5.6 Read Local Subnet Mask (GetLocalSubnetMask, 0x45)
- 6.3.5.7 Set Local Subnet Mask (SetLocalSubnetMask, 0x46)
- 6.3.5.8 Read Local WAGO Device Class (GetLocalDeviceClass, 0x47)
- 6.3.5.9 Write Local Device Class (SetLocalDeviceClass, 0x48)
- 6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
- 6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
- 6.3.5.12 Read Local Encryption Mode (GetLocalEncryptionMode, 0x4D)
- 6.3.5.13 Set Local Encryption Mode (SetLocalEncryptionMode, 0x4E)
- 6.3.5.14 Read Local Authentication Mode (GetLocalAuthenticationMode, 0x4F)
- 6.3.5.15 Set Local Authentication Mode (SetLocalAuthenticationMode, 0x50)
- 6.3.5.16 Read Local Bluetooth® Password (GetLocalPassphrase, 0x51)
- 6.3.5.17 Write Local Bluetooth® Password (SetLocalPassphrase, 0x52)
- 6.3.5.18 Delete Locally Saved Authorization (EraseLocalAuthentication, 0x53)
- 6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen, 0x54)
- 6.3.5.20 Read Role of the Local Device (GetLocalDeviceRole, 0x55)
- 6.3.5.21 Set Role of the Local Device (SetLocalDeviceRole, 0x56)
- 6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
- 6.3.5.23 Search for Remote Bluetooth® Device in the Wireless Network (ScanRemoteDevices, 0x80)
- 6.3.5.24 Read MAC-ID of a Remote Bluetooth® Device (GetRemoteDeviceMacID, 0x81)
- 6.3.5.25 Read Device Name of a Remote Bluetooth® Device (GetRemoteDeviceName, 0x82)
- 6.3.5.26 Enter External Device in the Table of Authorized Devices (AllowRemoteDevice, 0x83)
- 6.3.5.27 Read Back External Device from the Table of Authorized Devices (GetAllowedRemoteDevices, 0x84)
- 6.3.5.28 Grant Access Authorization for a Device (BindRemoteDevice, 0x85)
- 6.3.5.29 Delete Access Authorization for a Device (UnbindRemoteDevice, 0x86)
- 6.3.5.30 Read Access Authorization for Remote Devices (GetBoundRemoteDevices, 0x87)
- 6.3.5.31 Read Back the QoS Settings (GetConnectionQoS, 0x88)
- 6.3.5.32 Set the QoS Settings (SetConnectionQoS, 0x89)
- 6.3.5.33 Read Back Time Settings - Between Two Attempts to Establish a Connection (GetReconnectionTimePeriod, 0x8A)
- 6.3.5.34 Set Time Settings - Between Two Attempts to Establish a Connection (SetReconnectionTimePeriod, 0x8B)
- 6.3.5.35 Read the User-Friendly Name of an Authorized Device (GetUserfriendlyName, 0x8C)
- 6.3.5.36 Write the User-Friendly Name of an Authorized Device (SetUserfriendlyName, 0x8D)
- 6.3.6 Diagnostics
- 6.3.6.1 Read Status of the Local Bus Module (GetLocalDeviceStatus, 0xD0)
- 6.3.6.2 Read Status of the Wireless Network (GetNetworkStatus, 0xD1)
- 6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
- 6.3.6.4 Read Connection Quality (GetLinkQuality, 0xD5)
- 6.3.6.5 Read Signal Strength for a Connection (GetLinkSignalStrength, 0xD7)
- 6.3.6.6 Read Available Hopping Channels (GetAvailableChannelMap, 0xD8)
- 6.3.6.7 Set an LED (SetLED, 0xD9)
- 6.3.6.8 Mirror Mailbox for Test Purposes (MirrorMailboxCommand, 0xDA)
- 6.3.6.9 Read the Operating Time of the Module (GetLocalUpTime, 0xDB)
- 6.4 Extended Register Structure (Configuration Block)
- 6.5 Example Configurations using WAGO-I/O-CHECK
- 6.5.1 Startup with the Bluetooth® Parameterization Dialog
- 6.5.2 Startup using Mailbox Commands in the Process Data Dialog
- 6.5.2.1 Network Structure
- 6.5.2.2 Starting up the Bluetooth® Modules
- 6.5.2.2.1 Switch the Mailbox on
- 6.5.2.2.2 Reset Modules to Factory Default
- 6.5.2.2.3 Determining the Master
- 6.5.2.2.4 Querying the MAC Address
- 6.5.2.2.5 Loading the MAC Addresses of the Slaves into the Device List of the Master
- 6.5.2.2.6 Loading the MAC Address of the Master into the Device Lists of the Slaves
- 6.5.2.2.7 Binding the Slaves in the Master
- 6.5.2.2.8 Binding the Master in the Slaves
- 6.5.2.2.9 Setting the Communication Mode for Master and Slaves
- 6.5.2.3 Testing the Process Data Exchange
- Glossary
70 • Tools for Configuring and Operating
Configuring and Operating with WAGO-I/O-CHECK
WAGO-I/O-SYSTEM 750
I/O Modules
4.1.1.5.3 PI Mapping
To undertake settings on the "PI mapping" (process image mapping) page, the
process image size of the master must first be set.
Use the [Data Frame] button in the symbol bar to open the dialog for entering
the process image and mailbox sizes (see Figure 28).
Figure 28: Determine data framework g064444e
The following settings are possible (see Table 29):
Table 29: Determine data framework
Toggle field Settings
Process image size
12 bytes, 24 bytes, 48 bytes*
Mailbox size
6 bytes, 12 bytes, 18 bytes*
* Standard setting
Button Description
[Apply]
Transfers the altered parameters to the module's permanent memory. A
software reset is conducted so that the changes take effect. The dialog
remains open.
[Default]
Selects the standard setting for this module. Then transfer the parameters
to the permanent memory of the module by using the [Apply] button.
[Close]
Ends the parameterization dialog without transferring any altered pa-
rameters to the permanent memory of the module.
Note
Please note that the structure of the process image changes when the process im-
age size or mailbox size is changed. Therefore, changes in the configuration of
the superordinate control may be necessary.
On the "PI mapping" page, the slave process data is allocated to the slots in
the master (see
Figure 29). Up to 46 bytes of the process image are available
for this purpose (depending on which process image size was set in the "Data
framework" dialog). The control/status byte and internal byte are not taken
into consideration here.