User Manual
Table Of Contents
- Bluetooth® RF Transceiver 750-644
- 1 Important Comments
- 2 I/O Modules
- 2.1 Special Modules
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1.1.1 View
- 2.1.1.2 Description
- 2.1.1.3 Indicators
- 2.1.1.4 Schematic Diagram
- 2.1.1.5 Technical Data
- 2.1.1.6 Function Description
- 2.1.1.7 Operating Modes
- 2.1.1.8 Process Image
- 2.1.1.8.1 Process Data Communication
- 2.1.1.8.2 Mailbox Communication
- 2.1.1.8.3 Register Communication
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1 Special Modules
- 3 Configuration of a Bluetooth® Piconet
- 4 Tools for Configuring and Operating
- 4.1 Configuring and Operating with WAGO-I/O-CHECK
- 4.2 Configuring the Bluetooth® Module 750-644
- 5 Fieldbus-specific Additions
- 6 Appendix
- 6.1 Mailbox Commands
- 6.2 Return Values of Mailbox Commands
- 6.3 Mailbox Command References
- 6.3.1 General Commands
- 6.3.2 Block Transfer
- 6.3.3 Maintenance and Firmware
- 6.3.4 Process Image
- 6.3.5 Device Configuration
- 6.3.5.1 Read the Local Device Name(GetLocalDeviceName, 0x40)
- 6.3.5.2 Write the Local Device Name (SetLocalDeviceName, 0x41)
- 6.3.5.3 Read Local MAC ID (GetLocalMacID, 0x42)
- 6.3.5.4 Read Local IP Address (GetLocalIPAddress, 0x43)
- 6.3.5.5 Set Local IP Address (SetLocalIPAddress, 0x44)
- 6.3.5.6 Read Local Subnet Mask (GetLocalSubnetMask, 0x45)
- 6.3.5.7 Set Local Subnet Mask (SetLocalSubnetMask, 0x46)
- 6.3.5.8 Read Local WAGO Device Class (GetLocalDeviceClass, 0x47)
- 6.3.5.9 Write Local Device Class (SetLocalDeviceClass, 0x48)
- 6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
- 6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
- 6.3.5.12 Read Local Encryption Mode (GetLocalEncryptionMode, 0x4D)
- 6.3.5.13 Set Local Encryption Mode (SetLocalEncryptionMode, 0x4E)
- 6.3.5.14 Read Local Authentication Mode (GetLocalAuthenticationMode, 0x4F)
- 6.3.5.15 Set Local Authentication Mode (SetLocalAuthenticationMode, 0x50)
- 6.3.5.16 Read Local Bluetooth® Password (GetLocalPassphrase, 0x51)
- 6.3.5.17 Write Local Bluetooth® Password (SetLocalPassphrase, 0x52)
- 6.3.5.18 Delete Locally Saved Authorization (EraseLocalAuthentication, 0x53)
- 6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen, 0x54)
- 6.3.5.20 Read Role of the Local Device (GetLocalDeviceRole, 0x55)
- 6.3.5.21 Set Role of the Local Device (SetLocalDeviceRole, 0x56)
- 6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
- 6.3.5.23 Search for Remote Bluetooth® Device in the Wireless Network (ScanRemoteDevices, 0x80)
- 6.3.5.24 Read MAC-ID of a Remote Bluetooth® Device (GetRemoteDeviceMacID, 0x81)
- 6.3.5.25 Read Device Name of a Remote Bluetooth® Device (GetRemoteDeviceName, 0x82)
- 6.3.5.26 Enter External Device in the Table of Authorized Devices (AllowRemoteDevice, 0x83)
- 6.3.5.27 Read Back External Device from the Table of Authorized Devices (GetAllowedRemoteDevices, 0x84)
- 6.3.5.28 Grant Access Authorization for a Device (BindRemoteDevice, 0x85)
- 6.3.5.29 Delete Access Authorization for a Device (UnbindRemoteDevice, 0x86)
- 6.3.5.30 Read Access Authorization for Remote Devices (GetBoundRemoteDevices, 0x87)
- 6.3.5.31 Read Back the QoS Settings (GetConnectionQoS, 0x88)
- 6.3.5.32 Set the QoS Settings (SetConnectionQoS, 0x89)
- 6.3.5.33 Read Back Time Settings - Between Two Attempts to Establish a Connection (GetReconnectionTimePeriod, 0x8A)
- 6.3.5.34 Set Time Settings - Between Two Attempts to Establish a Connection (SetReconnectionTimePeriod, 0x8B)
- 6.3.5.35 Read the User-Friendly Name of an Authorized Device (GetUserfriendlyName, 0x8C)
- 6.3.5.36 Write the User-Friendly Name of an Authorized Device (SetUserfriendlyName, 0x8D)
- 6.3.6 Diagnostics
- 6.3.6.1 Read Status of the Local Bus Module (GetLocalDeviceStatus, 0xD0)
- 6.3.6.2 Read Status of the Wireless Network (GetNetworkStatus, 0xD1)
- 6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
- 6.3.6.4 Read Connection Quality (GetLinkQuality, 0xD5)
- 6.3.6.5 Read Signal Strength for a Connection (GetLinkSignalStrength, 0xD7)
- 6.3.6.6 Read Available Hopping Channels (GetAvailableChannelMap, 0xD8)
- 6.3.6.7 Set an LED (SetLED, 0xD9)
- 6.3.6.8 Mirror Mailbox for Test Purposes (MirrorMailboxCommand, 0xDA)
- 6.3.6.9 Read the Operating Time of the Module (GetLocalUpTime, 0xDB)
- 6.4 Extended Register Structure (Configuration Block)
- 6.5 Example Configurations using WAGO-I/O-CHECK
- 6.5.1 Startup with the Bluetooth® Parameterization Dialog
- 6.5.2 Startup using Mailbox Commands in the Process Data Dialog
- 6.5.2.1 Network Structure
- 6.5.2.2 Starting up the Bluetooth® Modules
- 6.5.2.2.1 Switch the Mailbox on
- 6.5.2.2.2 Reset Modules to Factory Default
- 6.5.2.2.3 Determining the Master
- 6.5.2.2.4 Querying the MAC Address
- 6.5.2.2.5 Loading the MAC Addresses of the Slaves into the Device List of the Master
- 6.5.2.2.6 Loading the MAC Address of the Master into the Device Lists of the Slaves
- 6.5.2.2.7 Binding the Slaves in the Master
- 6.5.2.2.8 Binding the Master in the Slaves
- 6.5.2.2.9 Setting the Communication Mode for Master and Slaves
- 6.5.2.3 Testing the Process Data Exchange
- Glossary
Configuration of a Bluetooth® Piconet • 59
Special Modules
WAGO-I/O-SYSTEM 750
I/O Modules
box"). In this case, you can also configure in such a way that the first slot has
no device allocated to it and the size of the first slot corresponds to the mail-
box size. This does mean, however, that one less device can be linked, but the
up-to-dateness of the process data is not dependent on the masking or unmask-
ing of the mailbox. But this is only possible for the module configured as the
master since slave process images always consist of only one individual slot
(in the master) and these do not begin until the third byte.
After configuring the process image and mailbox size, you can continue with
the device configuration. Please make sure that the module is in configuration
mode for the remainder of the steps.
Assign each device its intended role (master or slave). For each slave, enter
the master in the first slot in the list of allowed WAGO devices. For the mas-
ter, all intended slaves are assigned slots in the list of allowed WAGO or ex-
ternal devices. For each slot, set the planned data width (cutoff).
For master/slave communication over Bluetooth
®
, make sure that the settings
for encryption, authentication and PIN are identical in the devices. For maxi-
mum security, it is recommended that you keep the factory setting for "En-
cryption" at "On" and "Authentication" at "Password". The preset password,
“0000” should be changed to a project-specific password.
At the end of the device configuration process, you will change to communi-
cation mode - in the ad hoc or real-time profile, depending on the type of
slaves. With correct configuration, devices within range should automatically
establish a connection to each other. The establishment of a connection is es-
pecially fast if you first startup the slaves and then the master.
As soon as the connections are established, master and slaves exchange data
with each other, depending on the slot configuration. You can continue to set
mailbox commands in communication mode as well. An example being to
change the operating mode again or to query diagnostic information.
Section
4 below describes the Bluetooth
®
-specific configuration interface
WAGO-I/O-CHECK and the process of configuring a Bluetooth
®
module 750-
644. In Appendix 6.5, concrete example configurations are also provided.