2.1.1.8.3.5.2 Set Factory Settings (System Parameters)
Query (application)
Parameter Value Description
TGL_MS != TGL_SM Enter instruction
PRM_RW = TRUE Write access
A0...A7 255 Address of factory settings
Response (bus module)
Parameter Value Description
TGL_SM == TGL_MS Instruction completed
A0...A7 255 Set address of factory setting, mirrored
By writing 255 on the parameter address, the factory setting of the internal
data bus subsystem for the Bluetooth
®
module is restored. This includes the
size of the process image and mailbox. The settings of the Bluetooth
®
subsys-
tem can only be accessed through the mailbox interface and can be separately
reset to standard values via mailbox command (see Appendix 6.3.5.22).
2.1.1.8.3.5.3 Read/Write Parameters (Module-Specific)
Query (application)
Parameter Value Description
TGL_MS != TGL_SM Enter instruction
= FALSE Read access PRM_RW
= TRUE Write access
= FALSE Parameter data transmission is completed. MORE_PRM
= TRUE More parameter data to follow.
A0...A7 0...(n-1) Parameter address
PRM0... PRM15 0 ...65535 Parameter data write access