User Manual

Table Of Contents
I/O Modules 39
Special Modules
WAGO-I/O-SYSTEM 750
I/O Modules
In an additional example, we describe how the slot configurations behave in
conjunction with a configuration of the master (process image size = 48
bytes):
WAGO Table External Table
W1 permitted cutoff = 6 E1 linked cutoff = 6
W2 linked cutoff = 6 E2 linked cutoff = 6
W3 free cutoff = 0 E3 linked cutoff = 6
W4 linked cutoff = 4 E4 free cutoff = 0
W5 linked cutoff = 6 E5 free cutoff = 0
W6 free cutoff = 0 E6 free cutoff = 0
W7 linked cutoff = 6
Resulting process image in the master (ad hoc profile)
13 available slots, 5 of these with a width of 0 (W3, W6, E4, E5, E6)
Since no connection is established with W7, the slot remains filled with ze-
ros
W1 W2 W4 W5 W7 E1 E2 E3
0 48
Resulting process image in the master (real-time profile)
7 available slots, 2 of these with a width of 0 (W3, W6)
W1 W2 W4 W5 W7 free
0 48
E1 has been removed in the configuration mode (ad hoc profile)
"AllowRemoteDevice" with external Table E1 and MAD-ID: 0:0:0:0:0:0
After removing E1, the slot is filled with zeros. No data are transmitted to
this slot
W1 W2 W4 W5 W7 00000... E2 E3
0 48