User Manual
Table Of Contents
- Bluetooth® RF Transceiver 750-644
- 1 Important Comments
- 2 I/O Modules
- 2.1 Special Modules
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1.1.1 View
- 2.1.1.2 Description
- 2.1.1.3 Indicators
- 2.1.1.4 Schematic Diagram
- 2.1.1.5 Technical Data
- 2.1.1.6 Function Description
- 2.1.1.7 Operating Modes
- 2.1.1.8 Process Image
- 2.1.1.8.1 Process Data Communication
- 2.1.1.8.2 Mailbox Communication
- 2.1.1.8.3 Register Communication
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1 Special Modules
- 3 Configuration of a Bluetooth® Piconet
- 4 Tools for Configuring and Operating
- 4.1 Configuring and Operating with WAGO-I/O-CHECK
- 4.2 Configuring the Bluetooth® Module 750-644
- 5 Fieldbus-specific Additions
- 6 Appendix
- 6.1 Mailbox Commands
- 6.2 Return Values of Mailbox Commands
- 6.3 Mailbox Command References
- 6.3.1 General Commands
- 6.3.2 Block Transfer
- 6.3.3 Maintenance and Firmware
- 6.3.4 Process Image
- 6.3.5 Device Configuration
- 6.3.5.1 Read the Local Device Name(GetLocalDeviceName, 0x40)
- 6.3.5.2 Write the Local Device Name (SetLocalDeviceName, 0x41)
- 6.3.5.3 Read Local MAC ID (GetLocalMacID, 0x42)
- 6.3.5.4 Read Local IP Address (GetLocalIPAddress, 0x43)
- 6.3.5.5 Set Local IP Address (SetLocalIPAddress, 0x44)
- 6.3.5.6 Read Local Subnet Mask (GetLocalSubnetMask, 0x45)
- 6.3.5.7 Set Local Subnet Mask (SetLocalSubnetMask, 0x46)
- 6.3.5.8 Read Local WAGO Device Class (GetLocalDeviceClass, 0x47)
- 6.3.5.9 Write Local Device Class (SetLocalDeviceClass, 0x48)
- 6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
- 6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
- 6.3.5.12 Read Local Encryption Mode (GetLocalEncryptionMode, 0x4D)
- 6.3.5.13 Set Local Encryption Mode (SetLocalEncryptionMode, 0x4E)
- 6.3.5.14 Read Local Authentication Mode (GetLocalAuthenticationMode, 0x4F)
- 6.3.5.15 Set Local Authentication Mode (SetLocalAuthenticationMode, 0x50)
- 6.3.5.16 Read Local Bluetooth® Password (GetLocalPassphrase, 0x51)
- 6.3.5.17 Write Local Bluetooth® Password (SetLocalPassphrase, 0x52)
- 6.3.5.18 Delete Locally Saved Authorization (EraseLocalAuthentication, 0x53)
- 6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen, 0x54)
- 6.3.5.20 Read Role of the Local Device (GetLocalDeviceRole, 0x55)
- 6.3.5.21 Set Role of the Local Device (SetLocalDeviceRole, 0x56)
- 6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
- 6.3.5.23 Search for Remote Bluetooth® Device in the Wireless Network (ScanRemoteDevices, 0x80)
- 6.3.5.24 Read MAC-ID of a Remote Bluetooth® Device (GetRemoteDeviceMacID, 0x81)
- 6.3.5.25 Read Device Name of a Remote Bluetooth® Device (GetRemoteDeviceName, 0x82)
- 6.3.5.26 Enter External Device in the Table of Authorized Devices (AllowRemoteDevice, 0x83)
- 6.3.5.27 Read Back External Device from the Table of Authorized Devices (GetAllowedRemoteDevices, 0x84)
- 6.3.5.28 Grant Access Authorization for a Device (BindRemoteDevice, 0x85)
- 6.3.5.29 Delete Access Authorization for a Device (UnbindRemoteDevice, 0x86)
- 6.3.5.30 Read Access Authorization for Remote Devices (GetBoundRemoteDevices, 0x87)
- 6.3.5.31 Read Back the QoS Settings (GetConnectionQoS, 0x88)
- 6.3.5.32 Set the QoS Settings (SetConnectionQoS, 0x89)
- 6.3.5.33 Read Back Time Settings - Between Two Attempts to Establish a Connection (GetReconnectionTimePeriod, 0x8A)
- 6.3.5.34 Set Time Settings - Between Two Attempts to Establish a Connection (SetReconnectionTimePeriod, 0x8B)
- 6.3.5.35 Read the User-Friendly Name of an Authorized Device (GetUserfriendlyName, 0x8C)
- 6.3.5.36 Write the User-Friendly Name of an Authorized Device (SetUserfriendlyName, 0x8D)
- 6.3.6 Diagnostics
- 6.3.6.1 Read Status of the Local Bus Module (GetLocalDeviceStatus, 0xD0)
- 6.3.6.2 Read Status of the Wireless Network (GetNetworkStatus, 0xD1)
- 6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
- 6.3.6.4 Read Connection Quality (GetLinkQuality, 0xD5)
- 6.3.6.5 Read Signal Strength for a Connection (GetLinkSignalStrength, 0xD7)
- 6.3.6.6 Read Available Hopping Channels (GetAvailableChannelMap, 0xD8)
- 6.3.6.7 Set an LED (SetLED, 0xD9)
- 6.3.6.8 Mirror Mailbox for Test Purposes (MirrorMailboxCommand, 0xDA)
- 6.3.6.9 Read the Operating Time of the Module (GetLocalUpTime, 0xDB)
- 6.4 Extended Register Structure (Configuration Block)
- 6.5 Example Configurations using WAGO-I/O-CHECK
- 6.5.1 Startup with the Bluetooth® Parameterization Dialog
- 6.5.2 Startup using Mailbox Commands in the Process Data Dialog
- 6.5.2.1 Network Structure
- 6.5.2.2 Starting up the Bluetooth® Modules
- 6.5.2.2.1 Switch the Mailbox on
- 6.5.2.2.2 Reset Modules to Factory Default
- 6.5.2.2.3 Determining the Master
- 6.5.2.2.4 Querying the MAC Address
- 6.5.2.2.5 Loading the MAC Addresses of the Slaves into the Device List of the Master
- 6.5.2.2.6 Loading the MAC Address of the Master into the Device Lists of the Slaves
- 6.5.2.2.7 Binding the Slaves in the Master
- 6.5.2.2.8 Binding the Master in the Slaves
- 6.5.2.2.9 Setting the Communication Mode for Master and Slaves
- 6.5.2.3 Testing the Process Data Exchange
- Glossary
I/O Modules • 25
Special Modules
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.1.7.2.2 Block Transfer
The module parameters can be individually read and written using mailbox
commands (see Appendix 6.1). It is also possible, as an alternative, to upload
or download the complete configuration in 512-byte blocks. For example, a
created or read out configuration block can be used to set up and configure all
additional slaves.
512-byte blocks are sent. The transfer is opened each time by the group
DLD_START described in Appendix 6.3.2.1 and closed with DLD_END.
With each DLD_CONT command, one element of the block is transferred. Af-
ter transferring one 512-byte block, the module verifies the checksum.
After the copying process has been successfully completed, the module con-
firms the DLD_END command by sending the calculated checksum and the
return 0x00 (OK).
The format of the configuration block transferred by means of the DLD com-
mands is described in 6.4.
Table 7: Block transfer process using DLD commands
DLD commands Explanations
DLD_START Configuration of the block transfer
n x DLD_CONT Transfer of the 512-byte blocks in n* consecutive elements
(* depends on the mailbox size, see Appendix
6.3.2.2)
Procedure
DLD_END End of the block transfer, testing of the checksum
The exact mode of operation of the commands "DLD_START",
"DLD_CONT" and "DLD_END" can be found in Appendix 6.3.2.
2.1.1.7.2.3 Communication Mode – Real-Time Profile
In the real-time profile, signals can be monitored in real-time. The cycle and
error message time is assured making this profile especially suited for time-
critical applications such as system monitoring. In case of an error, the system
can be stopped immediately. The real-time network is invisible to Bluetooth
®
networks. Real-time capable masters only exchange data with directly con-
nected slaves.
Within the module, time intervals between different, repeating events are
monitored by Watchdog and other monitoring mechanisms. In case of distur-
bances, warnings/errors are signaled, depending on the type of disturbance, or