6.5.1.3 Testing the Process Data Exchange
The prerequisite for a successful test of the process data exchange is the cor-
rect configuration of the Bluetooth
®
device (see Appendix 6.5.1.2.1 through
6.5.1.2.3). The connection between the Bluetooth® master and slave is indi-
cated by the constant green blinking of LED 2 (see Figure 3) of the Blue-
tooth® master.
1. Close the Bluetooth
®
parameterization dialog.
2. Right click on master and slave, one after the other.
3. Choose Process Data in the context menu.
The process data dialog opens so that you can view the raw data.
4. Click with the right mouse button on the word "Input" in the dialog of the
master.
You have the choices Input, Output and Reset. From now on, you can switch
between the displays for input and output data using this menu (see Figure
52).
Figure 52: View of the process data g064466e
5. Enter any data in the "Output" dialog:
in the process image of the master and slave beginning with offset + 2
(bytes 0 and 1 are reserved for status information)
6. Test whether the input data of the first Bluetooth
®
module leads to the
correct output data of the second Bluetooth
®
module.