User Manual
Table Of Contents
- Bluetooth® RF Transceiver 750-644
- 1 Important Comments
- 2 I/O Modules
- 2.1 Special Modules
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1.1.1 View
- 2.1.1.2 Description
- 2.1.1.3 Indicators
- 2.1.1.4 Schematic Diagram
- 2.1.1.5 Technical Data
- 2.1.1.6 Function Description
- 2.1.1.7 Operating Modes
- 2.1.1.8 Process Image
- 2.1.1.8.1 Process Data Communication
- 2.1.1.8.2 Mailbox Communication
- 2.1.1.8.3 Register Communication
- 2.1.1 750-644 [Bluetooth® RF Transceiver]
- 2.1 Special Modules
- 3 Configuration of a Bluetooth® Piconet
- 4 Tools for Configuring and Operating
- 4.1 Configuring and Operating with WAGO-I/O-CHECK
- 4.2 Configuring the Bluetooth® Module 750-644
- 5 Fieldbus-specific Additions
- 6 Appendix
- 6.1 Mailbox Commands
- 6.2 Return Values of Mailbox Commands
- 6.3 Mailbox Command References
- 6.3.1 General Commands
- 6.3.2 Block Transfer
- 6.3.3 Maintenance and Firmware
- 6.3.4 Process Image
- 6.3.5 Device Configuration
- 6.3.5.1 Read the Local Device Name(GetLocalDeviceName, 0x40)
- 6.3.5.2 Write the Local Device Name (SetLocalDeviceName, 0x41)
- 6.3.5.3 Read Local MAC ID (GetLocalMacID, 0x42)
- 6.3.5.4 Read Local IP Address (GetLocalIPAddress, 0x43)
- 6.3.5.5 Set Local IP Address (SetLocalIPAddress, 0x44)
- 6.3.5.6 Read Local Subnet Mask (GetLocalSubnetMask, 0x45)
- 6.3.5.7 Set Local Subnet Mask (SetLocalSubnetMask, 0x46)
- 6.3.5.8 Read Local WAGO Device Class (GetLocalDeviceClass, 0x47)
- 6.3.5.9 Write Local Device Class (SetLocalDeviceClass, 0x48)
- 6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
- 6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
- 6.3.5.12 Read Local Encryption Mode (GetLocalEncryptionMode, 0x4D)
- 6.3.5.13 Set Local Encryption Mode (SetLocalEncryptionMode, 0x4E)
- 6.3.5.14 Read Local Authentication Mode (GetLocalAuthenticationMode, 0x4F)
- 6.3.5.15 Set Local Authentication Mode (SetLocalAuthenticationMode, 0x50)
- 6.3.5.16 Read Local Bluetooth® Password (GetLocalPassphrase, 0x51)
- 6.3.5.17 Write Local Bluetooth® Password (SetLocalPassphrase, 0x52)
- 6.3.5.18 Delete Locally Saved Authorization (EraseLocalAuthentication, 0x53)
- 6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen, 0x54)
- 6.3.5.20 Read Role of the Local Device (GetLocalDeviceRole, 0x55)
- 6.3.5.21 Set Role of the Local Device (SetLocalDeviceRole, 0x56)
- 6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
- 6.3.5.23 Search for Remote Bluetooth® Device in the Wireless Network (ScanRemoteDevices, 0x80)
- 6.3.5.24 Read MAC-ID of a Remote Bluetooth® Device (GetRemoteDeviceMacID, 0x81)
- 6.3.5.25 Read Device Name of a Remote Bluetooth® Device (GetRemoteDeviceName, 0x82)
- 6.3.5.26 Enter External Device in the Table of Authorized Devices (AllowRemoteDevice, 0x83)
- 6.3.5.27 Read Back External Device from the Table of Authorized Devices (GetAllowedRemoteDevices, 0x84)
- 6.3.5.28 Grant Access Authorization for a Device (BindRemoteDevice, 0x85)
- 6.3.5.29 Delete Access Authorization for a Device (UnbindRemoteDevice, 0x86)
- 6.3.5.30 Read Access Authorization for Remote Devices (GetBoundRemoteDevices, 0x87)
- 6.3.5.31 Read Back the QoS Settings (GetConnectionQoS, 0x88)
- 6.3.5.32 Set the QoS Settings (SetConnectionQoS, 0x89)
- 6.3.5.33 Read Back Time Settings - Between Two Attempts to Establish a Connection (GetReconnectionTimePeriod, 0x8A)
- 6.3.5.34 Set Time Settings - Between Two Attempts to Establish a Connection (SetReconnectionTimePeriod, 0x8B)
- 6.3.5.35 Read the User-Friendly Name of an Authorized Device (GetUserfriendlyName, 0x8C)
- 6.3.5.36 Write the User-Friendly Name of an Authorized Device (SetUserfriendlyName, 0x8D)
- 6.3.6 Diagnostics
- 6.3.6.1 Read Status of the Local Bus Module (GetLocalDeviceStatus, 0xD0)
- 6.3.6.2 Read Status of the Wireless Network (GetNetworkStatus, 0xD1)
- 6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
- 6.3.6.4 Read Connection Quality (GetLinkQuality, 0xD5)
- 6.3.6.5 Read Signal Strength for a Connection (GetLinkSignalStrength, 0xD7)
- 6.3.6.6 Read Available Hopping Channels (GetAvailableChannelMap, 0xD8)
- 6.3.6.7 Set an LED (SetLED, 0xD9)
- 6.3.6.8 Mirror Mailbox for Test Purposes (MirrorMailboxCommand, 0xDA)
- 6.3.6.9 Read the Operating Time of the Module (GetLocalUpTime, 0xDB)
- 6.4 Extended Register Structure (Configuration Block)
- 6.5 Example Configurations using WAGO-I/O-CHECK
- 6.5.1 Startup with the Bluetooth® Parameterization Dialog
- 6.5.2 Startup using Mailbox Commands in the Process Data Dialog
- 6.5.2.1 Network Structure
- 6.5.2.2 Starting up the Bluetooth® Modules
- 6.5.2.2.1 Switch the Mailbox on
- 6.5.2.2.2 Reset Modules to Factory Default
- 6.5.2.2.3 Determining the Master
- 6.5.2.2.4 Querying the MAC Address
- 6.5.2.2.5 Loading the MAC Addresses of the Slaves into the Device List of the Master
- 6.5.2.2.6 Loading the MAC Address of the Master into the Device Lists of the Slaves
- 6.5.2.2.7 Binding the Slaves in the Master
- 6.5.2.2.8 Binding the Master in the Slaves
- 6.5.2.2.9 Setting the Communication Mode for Master and Slaves
- 6.5.2.3 Testing the Process Data Exchange
- Glossary
174 • Appendix
Mailbox Command References
WAGO-I/O-SYSTEM 750
I/O Modules
6.3.6.3 Read Diagnostic Information (GetStatusMessage, 0xD2)
The command returns diagnostic information on occurring errors and warn-
ings from the local bus module.
When querying, a concrete object identification MBX_OBJECT_ID must be
indicated. The response then always contains the same MBX_OBJECT_ID
plus a defined status report MBX_STATE_MESSAGE. If the object identifi-
cation remains unknown, the system returns the information byte for executing
the command MBX_CMD_RESULT and the value
MBX_CMD_INVALID_ARG.
Each defined MBX_OBJECT_ID is always uniquely assigned a current status
report (usually "OK"). If an event occurs, the status report is changed each
time to mirror the most recently occurring event. The status report of an indi-
vidual MBX_OBJECT_ID is always overwritten with the next more recent
event as long as it is not "OK". The prioritization of error message before
warning message must always be observed.
Note
In the cyclical status report (C/S byte, LED activation), errors/warnings are
only displayed as long as the disturbed status lasts. The status report, on the
other hand, remains until it is overwritten (new message for the same Objec-
tID occurs).
Errors always have a higher priority than warnings in the display.
Only the status of WAGO devices is recorded.
Conditions
Mailbox size Operating mode/profile Device role
6 12 18 Config.
Real-
time
Ad hoc Master Slave
Save
config.
Restart
● ● ● ● ● ● ● ● - -
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_GETSTATUSMESSAGE
1 T -
2 MBX_OBJECT_ID (LSB)
3 MBX_OBJECT_ID_LO