6.3.5.22 Restore Factory Settings (SetFactorySettings, 0x57)
With call up, the locally saved configuration in the flash is overwritten by the
factory settings. The Bluetooth
®
subsystem is then restarted.
Conditions
Mailbox size Operating mode/profile Device role
6 12 18 Config.
Real-
time
Ad hoc Master Slave
Save
config.
Restart
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_SETFACTORYSETTINGS
1 T -
Response
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_SETFACTORYSETTINGS
1 T MBX_RESULT
Return values
Parameter Value Description
- - -