User Manual

Table Of Contents
142 Appendix
Mailbox Command References
WAGO-I/O-SYSTEM 750
I/O Modules
6.3.5.19 Read Length of the Flash Configuration (GetLocalDeviceConfigLen,
0x54)
With call up, the length (in bytes) of the locally saved configuration in the
flash of the Bluetooth
®
subsystem is passed back. This information is used by
the PLC for interpretation of data from the block commands.
Conditions
Mailbox size Operating mode/profile Device role
6 12 18 Config.
Real-
time
Ad hoc Master Slave
Save
config.
Restart
- - - -
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_GETLOCALDEVICECONFIGLEN
1 T -
Response
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_GETLOCALDEVICECONFIGLEN
1 T MBX_RESULT
2 MBX_CONFIG_LENGTH (LSB)
3 MBX_CONFIG_LENGTH (MSB)
Return values
Parameter Value Description
MBX_CONFIG_LENGTH
[0…65535]
Length of the configuration (number of bytes)
saved in the flash.