User Manual

Table Of Contents
14 I/O Modules
Special Modules
WAGO-I/O-SYSTEM 750
I/O Modules
2.1.1.3.2 Slave
Table 2: LED Slave Signals
LED Designation Status: Function
green Operating status OK (independent of radio
communication)
1
Operation status indi-
cator
red Disruption of the local internal data bus
connection, the field voltage or the internal
communication (circuit board)
green Connection to master established
green flashing Data transfer
off No master is configured for this slot.
yellow flash-
ing
Connection to the master is being estab-
lished (in communication mode only)
yellow System is being configured (in configura-
tion mode only) or connection to the mas-
ter could not be established (in communi-
cation mode only)
2
Connection display for
connected master
red Connection interrupted by error (in com-
munication mode only)
green Signal strength of the received signal good
yellow Signal strength of the received signal very
strong (solution: increase distance of the
device)
Red Signal strength of the received signal weak
(solution: reduce distance of the device).
3, 4
RSSI
Over- or under-
modulation of the
Bluetooth
®
receiver
off There is still no information on the signal
strength of the received signal (there is no
connection or there is a connection only
after a few seconds)
green low bit error rate <10
-3
yellow bit error rate 10
-2
to 10
-3
red high bit error rate > 10
-2
(bad transmission line)
5, 6
Connection quality
according to bit error
rate
off no active connection (similar RSSI)
green > 53 lines free (no or negligible third-party
activity in the frequency range)
yellow 39…53 free lines
red < 39 marked as free (massive third-party
activity in the frequency range)
7, 8
Interference display
Number of busy lines
in the 2.4 GHz fre-
quency range
off no active connection (similar RSSI)