6.3.5.11 Set Local Operation Mode (SetLocalOperationMode, 0x4A)
With call up, the operating mode and communication profile of the Bluetooth
®
subsystem are set. The call up is followed by a warm start of the Bluetooth
®
bus module in the chosen operating mode, saving any changes made to the
configuration.
Note
If an operating mode is chosen that has already been accepted by the module,
then the command is acknowledged with MBX_CMD_OK, but there is no
restart of the module. No changes made to the configuration are saved.
Conditions
Mailbox size Operating mode/profile Device role
6 12 18 Config.
Real-
time
Ad hoc Master Slave
Save
config.
Restart
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_SETLOCALOPERATIONMODE
1 T -
2 MBX_OPMODE_ID
3 MBX_COMMROFILE_ID
Arguments
Parameter Value Description
MBX_CM_OPMODE_CONF
(0x01)
Configuration mode (with
configuration profile only)
MBX_OPMODE_ID
MBX_CM_OPMODE_COMM
(0x02)
Communication mode
(with real-time profile or
ad hoc profile only)
MBX_CM_OPPROFILE_REALTIME
(0x01)
Real-time profile
MBX_CM_OPPROFILE_CONFIG
(0x02)
Configuration profile
MBX_COMMROFILE
_ID
MBX_CM_OPPROFILE_ADHOC
(0x03)
Ad hoc profile