User Manual

Table Of Contents
130 Appendix
Mailbox Command References
WAGO-I/O-SYSTEM 750
I/O Modules
6.3.5.10 Read Local Operation Mode (GetLocalOperationMode, 0x49)
With this command, the operating mode and communication profile of the lo-
cal Bluetooth
®
module are read.
Conditions
Mailbox size Operating mode/profile Device role
6 12 18 Config.
Real-
time
Ad hoc Master Slave
Save
config.
Restart
- -
Request
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_GETLOCALOPERATIONMODE
1 T -
Response
Byte 2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
0 MBX_GETLOCALOPERATIONMODE
1 T MBX_RESULT
2 MBX_OPMODE_ID
3 MBX_COMMROFILE_ID
Return values
Parameter Value Description
MBX_RESULT MBX_CMD_INVALID_ARG Parameter value(s) invalid
MBX_CM_OPMODE_CONF (0x01) Configuration mode MBX_OPMODE
_ID
MBX_CM_OPMODE_COMM (0x02) Communication mode
MBX_CM_OPPROFILE_REALTIME (0x01) Real-time profile
MBX_CM_OPPROFILE_CONFIG (0x02) Configuration profile
MBX_
COMMROFILE
_ID
MBX_CM_OPPROFILE_ADHOC (0x03) Ad hoc profile