Integration Manual

Table Of Contents
SARA-R5 series - System integration manual
UBX-19041356 - R03 System description Page 22 of 123
Confidential
1.6.1.2 Switch-on sequence from not-powered mode
Figure 11 shows the SARA-R500S / SARA-R510M8S switch-on sequence from the not-powered mode:
The external power supply is applied to the VCC module pins, representing the start-up event.
All the generic digital pins are tri-stated until the switch-on of their supply source (V_INT).
The internal reset signal is held low: the baseband core and all digital pins are held in reset state.
When the internal reset signal is released, any digital pin is set in the correct sequence from the
reset state to the default operational configured state. The duration of this phase differs within
generic digital interfaces and USB interface due to host / device enumeration timings.
If enabled, a greeting message is sent on the RXD pin (for more details, see SARA-R5 series AT
commands manual [2])
The module is fully ready to operate after all interfaces are configured.
VCC
PWR_ON
RESET_N
V_INT
Internal reset
RXD
System state
BB pads state Operational
OFF
Tristate / Floating
Internal reset
Internal reset → Operational
ON
Start of interface
configuration
Module interfaces
are configured
Start-up
event
Greeting
Figure 11: SARA-R500S / SARA-R510M8S switch-on sequence description from not-powered mode
Figure 12 shows the SARA-R510S modules switch-on sequence from the not-powered mode:
The external power supply is applied to the VCC module pins
The PWR_ON pin is held low for a valid time, representing the start-up event.
All the generic digital pins are tri-stated until the switch-on of their supply source (V_INT).
The internal reset signal is held low: the baseband core and all digital pins are held in reset state.
When the internal reset signal is released, any digital pin is set in the correct sequence from the
reset state to the default operational configured state. The duration of this phase differs within
generic digital interfaces and USB interface due to host / device enumeration timings.
If enabled, a greeting message is sent on the RXD pin (for more details, see SARA-R5 series AT
commands manual [2])
The module is fully ready to operate after all interfaces are configured.
VCC
PWR_ON
RESET_N
V_INT
Internal reset
RXD
System state
BB pads state Operational
OFF
Tristate / Floating
Internal reset
Internal reset → Operational
ON
Start of interface
configuration
Module interfaces
are configured
Start-up
event
~? s
0 s
Greeting
Figure 12: SARA-R510S switch-on sequence description from not-powered mode