Integration Manual

Table Of Contents
SARA-R5 series - System integration manual
UBX-19041356 - R03 System description Page 21 of 123
Confidential
1.6 System function interfaces
1.6.1 Module power-on
1.6.1.1 Switch-on events
When the SARA-R500S and SARA-R510M8S modules are in the not-powered mode (i.e. switched off,
with the VCC module supply not applied), the switch on routine can be triggered by:
Applying a voltage at the VCC module supply input within the operating range (see SARA-R5 series
data sheet [1]).
When the SARA-R510S modules are in the not-powered mode (i.e. switched off, with the VCC module
supply not applied), the switch on routine can be triggered by:
Applying a voltage at the VCC module supply input within the operating range (see SARA-R5 series
data sheet [1]), and then forcing a low level at the PWR_ON input pin (normally high due to internal
pull-up) for a valid time period.
When the SARA-R5 series modules are in the power-off mode (i.e. switched off, but with a valid voltage
present at the VCC module supply input) or in deep-sleep mode, they can be switched on or they can
be woken up as following:
Forcing a low level at the PWR_ON input pin (normally high due to internal pull-up) for a valid time
period.
As illustrated in Figure 10, the PWR_ON input pin is equipped with an internal pull-up resistor. Detailed
electrical characteristics with voltages and timings are described in the SARA-R5 series data
sheet [1].
Baseband processor
15
PWR_ON
SARA-R5 series
Power-on
Power management
Power-on
Figure 10: SARA-R5 series PWR_ON input equivalent circuit description