6Call control
Page 39 of 308
6.4Automatic answer S0
S0
Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No Profile No - +CME Error
6.4.1Description
Controls the automatic answering feature of the DCE. If set to 0, the automatic answering is disabled,
otherwise it causes the DCE to answer when the incoming call indication (RING) has occurred the number of
times indicated by the value.
For an incoming CSD call, if the autoanswering is enabled and the <value> parameter of &D command is
set to 2, the autoanswering only works if the DTR line of the AT interface with activated autoanswering
is set to ON. Otherwise, if DTR is OFF, then the call is rejected. If the <value> parameter of &D command
is not set to 2, the DTR state has no impact on autoanswering.
6.4.2Syntax
Type Syntax Response Example
Set ATS0=<value> OK ATS0=2
OK
Read ATS0? <value>
OK
000
OK
6.4.3Defined values
Parameter Type Description
<value> Number Value in the range 0-255; the answer to the read command is in "xxx" format.
0 (factory-programmed value): disables automatic answer mode
1-255: enables automatic answering after specified number of rings
6.4.4Notes
SARA-R404M / SARA-R410M-01B / SARA-R410M-02B / SARA-R410M-52B
The voice call autoanswering is not supported and the command is therefore not effective.