18Internet protocol transport layer
Page 201 of 308
18.21Character trigger configuration for Direct Link
+UDCONF=7
+UDCONF=7
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
18.21.1Description
Sets the character trigger of the interested socket identifier for the data transmission enhanced Direct Link.
18.21.2Syntax
Type Syntax Response Example
Set AT+UDCONF=7,<socket_id>,
<character_trigger>
OK AT+UDCONF=7,0,13
OK
Read AT+UDCONF=7,<socket_id> +UDCONF: 7,<socket_id>,
<character_trigger>
OK
AT+UDCONF=7,0
+UDCONF: 7,0,13
OK
18.21.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the Direct Link settings.
The allowed range is 0-6
<character_trigger> Number Enhanced Direct Link character trigger, the value represents the ASCII code (in base
10) of the character to be used as character trigger. The allowed range is -1, 0-255, the
factory-programmed value is -1; -1 means trigger disabled
18.22Congestion timer configuration for Direct Link
+UDCONF=8
+UDCONF=8
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
18.22.1Description
Sets the congestion timer of the interested socket identifier for the data transmission enhanced Direct Link.
18.22.2Syntax
Type Syntax Response Example
Set AT+UDCONF=8,<socket_id>,
<congestion_timer>
OK AT+UDCONF=8,0,120000
OK
Read AT+UDCONF=8,<socket_id> +UDCONF: 8,<socket_id>,
<congestion_timer>
OK
AT+UDCONF=8,0
+UDCONF: 8,0,120000
OK
18.22.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the Direct Link settings.