User Manual

Table Of Contents
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R11
18Internet protocol transport layer
Page 200 of 308
18.19.2Syntax
Type Syntax Response Example
Set AT+UDCONF=5,<socket_id>,
<timer_trigger>
OK AT+UDCONF=5,0,500
OK
Read AT+UDCONF=5,<socket_id> +UDCONF: 5,<socket_id>,<timer_
trigger>
OK
AT+UDCONF=5,0
+UDCONF: 5,0,500
OK
18.19.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the UDP Direct Link settings. The range is 0-6.
<timer_trigger> Number Enhanced Direct Link sending timer trigger (in milliseconds); valid range is 0, 100-120
000; the factory-programmed value is 500 ms for UDP, 0 for TCP, 0 means trigger
disabled.
18.19.4Notes
SARA-R4 / SARA-N4
The factory-programmed value is 1000 ms for TCP.
18.20Data Length Trigger configuration for Direct Link
+UDCONF=6
+UDCONF=6
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
18.20.1Description
Sets the data length trigger of the interested socket identifier for the data transmission enhanced Direct Link.
18.20.2Syntax
Type Syntax Response Example
Set AT+UDCONF=6,<socket_id>,<data_
length_trigger>
OK AT+UDCONF=6,0,1024
OK
Read AT+UDCONF=6,<socket_id> +UDCONF: 6,<socket_id>,<data_
length_trigger>
OK
AT+UDCONF=6,0
+UDCONF: 6,0,1024
OK
18.20.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the UDP Direct Link settings.
Valid range is 0-6
<data_length_
trigger>
Number Enhanced Direct Link data length trigger in bytes, valid range is 0, 3 1472 for UDP and
0, 3-2048 for TCP, the factory-programmed value is 1024 for UDP, 0 for TCP, 0 means
trigger disabled