User Manual

Table Of Contents
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R11
18Internet protocol transport layer
Page 199 of 308
18.17.2Syntax
Type Syntax Response Example
Set AT+UDCONF=2,<socket_id>,
<packet_size>
OK AT+UDCONF=2,1,1024
OK
Read AT+UDCONF=2,<socket_id> +UDCONF: 2,<socket_id>,<packet_
size>
OK
AT+UDCONF=2,1
+UDCONF: 2,1,1024
OK
18.17.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the UDP Direct Link settings.
Valid range is 0-6
<packet_size> Number Packet size (in bytes) for UDP direct link; valid range is 100-1472; the factory-
programmed value is 1024 bytes
18.18UDP Direct Link Sending timer configuration
+UDCONF=3
+UDCONF=3
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
18.18.1Description
Configures the UDP direct link set sending timer.
18.18.2Syntax
Type Syntax Response Example
Set AT+UDCONF=3,<socket_id>,
<sending_timer_timeout>
OK AT+UDCONF=3,1,1000
OK
Read AT+UDCONF=3,<socket_id> +UDCONF: 3,<socket_id>,<sending_
timer_timeout>
OK
AT+UDCONF=3,1
+UDCONF: 3,1,1000
OK
18.18.3Defined values
Parameter Type Description
<socket_id> Number Socket identifier; used when changing the UDP Direct Link settings.
Allowed range is 0-6
<sending_timer_
timeout>
Number Sending timer (in milliseconds) for UDP direct link; valid range is 100-120000; the
default value is 1000 ms
18.19Timer Trigger configuration for Direct Link +UDCONF=5
+UDCONF=5
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
18.19.1Description
Sets the timer trigger of the interested socket identifier for the data transmission enhanced Direct Link.