User Manual

Table Of Contents
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R11
14System features
Page 159 of 308
14.10Cancel LWM2M FOTA Download +ULWM2M=0
+ULWM2M=0
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full Yes No No - -
14.10.1Description
When a LWM2M session is in progress and the firmware is being download to the device, the download can be
canceled by issuing this command. To make use of this command, URCs for LWM2M FOTA sessions must be
enabled. See +ULWM2MSTAT for details on enabling LWM2M URCs.
14.10.2Syntax
Type Syntax Response Example
Set AT+ULWM2M=0 OK AT+ULWM2M=0
OK
14.11uFOTA configuration +UFOTACONF
+UFOTACONF
SARA-R410M-52BModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No NVM No - +CME Error
14.11.1Description
Configures the uFOTA registration and timer for periodic connections to the uFOTA server.
14.11.2Syntax
Type Syntax Response Example
Generic syntax
Set AT+UFOTACONF=<mode>,
<param>
OK AT+UFOTACONF=2,604800
OK
uFOTA registration
Set AT+UFOTACONF=1,<registration> OK AT+UFOTACONF=1,1
OK
uFOTA periodic connection
Set AT+UFOTACONF=2,<timer> OK AT+UFOTACONF=2,604800
OK
Read AT+UFOTACONF=<mode> +UFOTACONF: <mode>,<param>
OK
+UFOTACONF: 1,1
OK
Test AT+UFOTACONF=? +UFOTACONF: (list of supported
<mode>s),(list of supported
<param>s)
OK
+UFOTACONF: (1-2),(-1,1-
4294967295)
OK
14.11.3Defined values
Parameter Type Description
<mode> Number uFOTA parameter to be configured:
1: module registration to uFOTA server
2: timer for periodic connection to the uFOTA server
<registration> Number uFOTA registration: