User Manual

Table Of Contents
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R11
13Packet switched data services
Page 124 of 308
Parameter Type Description
o 0 (factory-programmed value): subscribed
o 1: high
o 2: normal
o 3: low
11: QoS delay - the <param_val> parameter selects the delay class:
o 0 (factory-programmed value): subscribed
o 1: class 1
o 2: class 2
o 3: class 3
o 4: best effort
12: QoS reliability - the <param_val> parameter selects the reliability class:
o 0 (factory-programmed value): subscribed
o 1: class 1 (Interpreted as class 2)
o 2: class 2 (GTP Unack, LLC Ack and Protected, RLC Ack)
o 3: class 3 (GTP Unack, LLC Unack and Protected, RLC Ack)
o 4: class 4 (GTP Unack, LLC Unack and Protected, RLC Unack)
o 5: class 5 (GTP Unack, LLC Unack and Unprotected, RLC Unack)
o 6: class 6 (Interpreted as class 3)
13: QoS peak rate - the <param_val> parameter selects the peak throughput in
range 0-9. The factory-programmed value is 0.
14: QoS mean rate - the <param_val> parameter selects the mean throughput in
range 0-18, 31. The factory-programmed value is 0.
15: minimum QoS precedence - the <param_val> parameter selects the acceptable
value for the precedence class:
o 0 (factory-programmed value): subscribed
o 1: high
o 2: normal
o 3: low
16: minimum QoS delay - the <param_val> parameter selects the acceptable value
for the delay class:
o 0 (factory-programmed value): subscribed
o 1: class 1
o 2: class 2
o 3: class 3
o 4: best effort
17: minimum QoS reliability - the <param_val> parameter selects the minimum
acceptable value for the reliability class:
o 0 (factory-programmed value): subscribed
o 1: class 1 (Interpreted as class 2)
o 2: class 2 (GTP Unack, LLC Ack and Protected, RLC Ack)
o 3: class 3 (GTP Unack, LLC Unack and Protected, RLC Ack)
o 4: class 4 (GTP Unack, LLC Unack and Protected, RLC Unack)
o 5: class 5 (GTP Unack, LLC Unack and Unprotected, RLC Unack)
o 6: class 6 (Interpreted as class 3)
18: minimum QoS peak rate - the <param_val> parameter selects the acceptable
value for the peak throughput in range 0-9. The factory-programmed value is 0.
19: minimum QoS mean rate - the <param_val> parameter selects the acceptable
value for the mean throughput in range 0-18, 31. The factory-programmed value is 0.
20: 3G QoS delivery order - the <param_val> parameter selects the acceptable value
for the delivery order:
o 0 (factory-programmed value): subscribed
o 1: enable
o 2: disable
21: 3G QoS erroneous SDU delivery - the <param_val> parameter selects the
acceptable value for the erroneous SDU delivery:
o 0 (factory-programmed value): subscribed
o 1: no detection
o 2: enable
o 3: disable