User Manual
Table Of Contents
- Preface
- Contents
- 1 AT command settings
- 2 General operation
- 3 IPC - Inter Processor Communication
- 4 General
- 4.1 Manufacturer identification +CGMI
- 4.2 Manufacturer identification +GMI
- 4.3 Model identification +CGMM
- 4.4 Model identification +GMM
- 4.5 Firmware version identification +CGMR
- 4.6 Firmware version identification +GMR
- 4.7 IMEI identification +CGSN
- 4.8 IMEI identification +GSN
- 4.9 Identification information I
- 4.10 TE character set configuration +CSCS
- 4.11 International mobile subscriber identification +CIMI
- 4.12 Card identification +CCID
- 4.13 Repeat last command A/
- 5 Mobile equipment control and status
- 6 Call control
- 7 Network service
- 7.1 Subscriber number +CNUM
- 7.2 Signal quality +CSQ
- 7.3 Extended signal quality +CESQ
- 7.4 Operator selection +COPS
- 7.5 Radio Access Technology (RAT) selection +URAT
- 7.6 Network registration status +CREG
- 7.7 Network selection control +PACSP
- 7.8 Channel and network environment description +UCGED
- 7.9 Edit Verizon wireless APN table +VZWAPNE
- 7.10 Read RSRP values +VZWRSRP
- 7.11 Read RSRQ values +VZWRSRQ
- 7.12 eDRX setting +CEDRXS
- 7.13 eDRX read dynamic parameters +CEDRXRDP
- 7.14 Set MNO profile +UMNOPROF
- 7.15 Band selection bitmask +UBANDMASK
- 8 Security
- 9 Short Messages Service
- 9.1 Introduction
- 9.2 Select message service +CSMS
- 9.3 Preferred message storage +CPMS
- 9.4 Preferred message format +CMGF
- 9.5 Save settings +CSAS
- 9.6 Restore settings +CRES
- 9.7 New message indication +CNMI
- 9.8 Read message +CMGR
- 9.9 New message acknowledgement to MT +CNMA
- 9.10 List message +CMGL
- 9.11 Send message +CMGS
- 9.12 Write message to memory +CMGW
- 9.13 Send message from storage +CMSS
- 9.14 Set text mode parameters +CSMP
- 9.15 Delete message +CMGD
- 9.16 Service center address +CSCA
- 9.17 Read concatenated message +UCMGR
- 9.18 List concatenated message +UCMGL
- 9.19 Send concatenated message +UCMGS
- 9.20 Write concatenated message to memory +UCMGW
- 9.21 More messages to send +CMMS
- 9.22 Sending of originating data via the control plane +CSODCP
- 9.23 Terminating data reporting via control plane +CRTDCP
- 10 V24 control and V25ter
- 10.1 Introduction
- 10.2 Circuit 109 behavior &C
- 10.3 Circuit 108/2 behavior &D
- 10.4 DSR override &S
- 10.5 Flow control &K
- 10.6 DTE-DCE character framing +ICF
- 10.7 DTE-DCE local flow control +IFC
- 10.8 Set flow control \Q
- 10.9 UART data rate configuration +IPR
- 10.10 Return to on-line data state O
- 10.11 Escape character S2
- 10.12 Command line termination character S3
- 10.13 Response formatting character S4
- 10.14 Command line editing character S5
- 10.15 Pause before blind dialling S6
- 10.16 Connection completion timeout S7
- 10.17 Command dial modifier time S8
- 10.18 Automatic disconnect delay S10
- 10.19 Escape prompt delay (EPD) S12
- 10.20 Command echo E
- 10.21 Result code suppression Q
- 10.22 DCE response format V
- 10.23 Result code selection and call progress monitoring control X
- 10.24 Reset to default configuration Z
- 10.25 Set to factory defined configuration &F
- 10.26 Display current configuration &V
- 11 SIM management
- 12 SIM toolkit
- 13 Packet switched data services
- 13.1 PDP contexts and parameter definition
- 13.2 PPP LCP handshake behaviour
- 13.3 PDP context definition +CGDCONT
- 13.4 Packet switched data configuration +UPSD
- 13.5 GPRS attach or detach +CGATT
- 13.6 PDP context activate or deactivate +CGACT
- 13.7 Enter PPP state/GPRS dial-up D*
- 13.8 Show PDP address +CGPADDR
- 13.9 GPRS event reporting +CGEREP
- 13.10 GPRS network registration status +CGREG
- 13.11 Manual deactivation of a PDP context H
- 13.12 UE modes of operation for EPS +CEMODE
- 13.13 EPS network registration status +CEREG
- 13.14 Delete non-active PDP contexts +CGDEL
- 13.15 Configure the authentication parameters of a PDP/EPS bearer +UAUTHREQ
- 13.16 PDP IP configuration when roaming +UDCONF=75
- 13.17 Enable/Disable data when roaming +UDCONF=76
- 14 System features
- 14.1 Firmware installation +UFWINSTALL
- 14.2 Firmware update Over AT (FOAT) +UFWUPD
- 14.3 Antenna detection +UANTR
- 14.4 Power saving control (Power SaVing) +UPSV
- 14.5 End user test +UTEST
- 14.6 Internal temperature monitor +UTEMP
- 14.7 Power Saving Mode Setting +CPSMS
- 14.8 Power Saving Mode Assigned Values +UCPSMS
- 14.9 Set LWM2M FOTA URCs +ULWM2MSTAT
- 14.10 Cancel LWM2M FOTA Download +ULWM2M=0
- 14.11 uFOTA configuration +UFOTACONF
- 14.12 Last gasp configuration +ULGASP
- 14.13 LWM2M host device information +UHOSTDEV
- 14.14 RING line configuration +URINGCFG
- 15 GPIO
- 15.1 Introduction
- 15.1.1 GPIO functions
- 15.1.2 GPIO mapping
- 15.1.3 Network status indication
- 15.1.3.1 No service (no network coverage or not registered)
- 15.1.3.2 Registered home network 2G
- 15.1.3.3 Registered home network 3G
- 15.1.3.4 Registered home network Cat NB1
- 15.1.3.5 Registered roaming 2G
- 15.1.3.6 Registered roaming 3G
- 15.1.3.7 Registered roaming Cat NB1
- 15.1.3.8 Data transmission
- 15.1.3.9 Data transmission roaming
- 15.2 GPIO select configuration command +UGPIOC
- 15.3 GPIO read command +UGPIOR
- 15.4 GPIO set command +UGPIOW
- 15.1 Introduction
- 16 File System
- 17 DNS
- 18 Internet protocol transport layer
- 18.1 Introduction
- 18.2 IPv4/IPv6 addressing
- 18.3 Create Socket +USOCR
- 18.4 SSL/TLS mode configuration on TCP socket +USOSEC
- 18.5 Set socket option +USOSO
- 18.6 Get Socket Option +USOGO
- 18.7 Close Socket +USOCL
- 18.8 Get Socket Error +USOER
- 18.9 Connect Socket +USOCO
- 18.10 Write socket data +USOWR
- 18.11 SendTo command (UDP only) +USOST
- 18.12 Read Socket Data +USORD
- 18.13 Receive From command (UDP only) +USORF
- 18.14 Set Listening Socket +USOLI
- 18.15 HEX mode configuration +UDCONF=1
- 18.16 Set socket in Direct Link mode +USODL
- 18.17 UDP Direct Link Packet Size configuration +UDCONF=2
- 18.18 UDP Direct Link Sending timer configuration +UDCONF=3
- 18.19 Timer Trigger configuration for Direct Link +UDCONF=5
- 18.20 Data Length Trigger configuration for Direct Link +UDCONF=6
- 18.21 Character trigger configuration for Direct Link +UDCONF=7
- 18.22 Congestion timer configuration for Direct Link +UDCONF=8
- 18.23 Socket control +USOCTL
- 18.24 Configure Dormant Close Socket Behavior +USOCLCFG
- 19 SSL/TLS
- 20 FTP
- 21 HTTP
- 22 GNSS
- 22.1 NMEA
- 22.2 GNSS power management +UGPS
- 22.3 Assisted GNSS unsolicited indication +UGIND
- 22.4 GNSS profile configuration +UGPRF
- 22.5 Aiding server configuration +UGSRV
- 22.6 GNSS aiding request command +UGAOS
- 22.7 Send of UBX string +UGUBX
- 22.8 GNSS indications timer +UGTMR
- 22.9 Get GNSS time and date +UGZDA
- 22.10 Get GNSS fix data +UGGGA
- 22.11 Get geographic position +UGGLL
- 22.12 Get number of GNSS satellites in view +UGGSV
- 22.13 Get recommended minimum GNSS data +UGRMC
- 22.14 Get course over ground and ground speed +UGVTG
- 22.15 Get satellite information +UGGSA
- 22.16 Ask for localization information +ULOC
- 22.17 Localization information request status unsolicited indication +ULOCIND
- 22.18 GNSS sensor configuration +ULOCGNSS
- 23 I2C
- 24 MQTT
- A Appendix: Error result codes
- B Appendix: AT Commands List
- C Appendix: UDP Direct Link workflow
- D Appendix: Glossary
- Related documents
- Revision history
- Contact
SARA-R4/N4 series-AT Commands Manual
UBX-17003787 - R11
10V24 control and V25ter
Page 100 of 308
10.9UART data rate configuration +IPR
+IPR
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412MModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial No Profile No - +CME Error
10.9.1Description
Specifies the data rate at which the DCE accepts commands on the UART interface. The full range of data
rates depends on HW or other criteria.
When supported, the autobauding feature allows baud rate recognition by the DCE when it operates in
command mode.
The command settings are ignored when the AT command interface runs either on the USB or on the SPI
interface. The DCE sends the "OK" final result code but the command will have no effect.
10.9.2Syntax
Type Syntax Response Example
Set AT+IPR=[<rate>] OK AT+IPR=9600
OK
Read AT+IPR? +IPR: <rate>
OK
+IPR: 9600
OK
Test AT+IPR=? +IPR: (list of supported
autodetectable <rate> values)[,(list
of fixed only <rate> values)]
OK
+IPR: (0,2400,4800,9600,19200,
38400,57600,115200),()
OK
10.9.3Defined values
Parameter Type Description
<rate> Number Baud rate
• 0 (factory-programmed value): autobauding
• 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 (default value), 230400, 460
800, 921600, 3000000, 3250000, 6000000, 6500000
10.9.4Notes
• On the UART AT interface, after the reception of the "OK" result code for the +IPR command, the DTE
shall wait for at least 100 ms before issuing a new AT command; this is to guarantee a proper baud rate
reconfiguration.
SARA-R4 / SARA-N4
• Automatic baud rate detection is not implemented (<rate>=0 is not supported).
• The factory-programmed value for <rate> is 115200.
• This command is not supported in the multiplexer mode. See the +CMUX AT command for more details.
SARA-R404M / SARA-R410M-01B / SARA-R410M-02B
• Valid baud rates <rate>= 9600, 19200, 38400, 57600, 115200.
SARA-R410M-52B / SARA-N4
• Valid baud rates <rate>= 9600, 19200, 38400, 57600, 115200, 230400, 460800.