SARA-R4/N4 series Size-optimized LTE Cat M1 / NB1 / GPRS modules AT Commands Manual Abstract Description of standard and proprietary AT commands used with u-blox cellular modules. www.u-blox.
SARA-R4/N4 series - AT Commands Manual Document Information Title SARA-R4/N4 series Subtitle Size-optimized LTE Cat M1 / NB1 / GPRS modules Document type AT Commands Manual Document number UBX-17003787 Revision and date R11 13-Sep-2018 Disclosure restriction u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights.
SARA-R4/N4 series - AT Commands Manual Preface Applicable products This document applies to the following products: Name SARA-R404M Type number SARA-R404M-00B-00 Modem version K0.0.00.00.07.06 Application version N.A. PCN reference UBX-17047084 SARA-R410M SARA-R404M-00B-01 SARA-R410M-01B-00 K0.0.00.00.07.08 L0.0.00.00.02.03 N.A. N.A. UBX-18053670 UBX-17051617 SARA-R410M-02B-00 L0.0.00.00.05.06 A02.00 UBX-18010263 SARA-R410M-52B-00 SARA-R412M-02B-00 SARA-N410-02B-00 L0.0.00.00.06.05 M0.05.
SARA-R4/N4 series - AT Commands Manual - No: the current command setting is volatile and cannot be saved o Can be aborted - Yes: the command execution can be aborted if a character is sent to the DCE during the command execution - No: the command cannot be aborted during the command execution o Response time: estimated maximum time to get the final result code for the AT command execution.
SARA-R4/N4 series - AT Commands Manual By E-mail If you have technical problems or cannot find the required information in the provided documents, contact the nearest of the Technical Support offices by email. Use our service pool email addresses rather than any personal email address of our staff. This makes sure that your request is processed as soon as possible. You will find the contact details at the end of the document.
SARA-R4/N4 series - AT Commands Manual Contents 1 AT command settings......................................................................................................11 1.1 1.2 1.3 2 General operation.............................................................................................................16 2.1 2.2 3 Multiplexing mode +CMUX............................................................................................................................ 19 General....................
SARA-R4/N4 series - AT Commands Manual 7.11 Read RSRQ values +VZWRSRQ................................................................................................................. 56 7.12 eDRX setting +CEDRXS............................................................................................................................... 57 7.13 eDRX read dynamic parameters +CEDRXRDP....................................................................................... 58 7.14 Set MNO profile +UMNOPROF.....
SARA-R4/N4 series - AT Commands Manual 10.25 10.26 11 SIM management........................................................................................................... 111 11.1 11.2 11.3 12 Firmware installation +UFWINSTALL..................................................................................................... 143 Firmware update Over AT (FOAT) +UFWUPD...................................................................................... 144 Antenna detection +UANTR.................
SARA-R4/N4 series - AT Commands Manual 16.6 16.7 16.8 17 DNS................................................................................................................................... 179 17.1 18 Introduction................................................................................................................................................... 181 IPv4/IPv6 addressing.......................................................................................................................
SARA-R4/N4 series - AT Commands Manual 23 22.11 Get geographic position +UGGLL..........................................................................................................235 22.12 Get number of GNSS satellites in view +UGGSV...............................................................................235 22.13 Get recommended minimum GNSS data +UGRMC..........................................................................236 22.14 Get course over ground and ground speed +UGVTG.............
SARA-R4/N4 series - AT Commands Manual 1 AT command settings u-blox cellular modules provide at least one physical serial interface that is compliant to V.24 [26]. When the module is powered on, it enters the command mode. For more details on command mode, see Chapter 1.1. For module and hyper terminal connection and settings see the corresponding evaluation kit user guide. 1.
SARA-R4/N4 series - AT Commands Manual The command description defines each named parameter with its type, its range (valid / acceptable values), the default value (when available) and the factory-programmed value (when applicable). For default value it is intended the value automatically set if the parameter is omitted and at the module power-on (if the command setting is not stored in NVM/profile).
SARA-R4/N4 series - AT Commands Manual 1.1.4.1 Concatenation of AT commands More than one AT command can be entered on the same command line. The "AT" prefix must be provided only at the beginning of the command line. Each command must be separated by using a semicolon as delimiter only if the command has a "+" character as prefix.
SARA-R4/N4 series - AT Commands Manual Verbose Numeric Command aborted 3000 Result code type Description In case of data/fax call, see Circuit 108/2, +++ behaviour for the different &D: summarizing table to return in command mode and disconnect the call. Final Command execution aborted issuing a character to the DCE Table 1: Allowed result codes SARA-R4 / SARA-N4 The AT commands can not be aborted, except if explicitly stated in the corresponding AT command description.
SARA-R4/N4 series - AT Commands Manual AT command S0 S2 S3 S4 S5 S6 S7 S8 S10 S12 S Number 0 2 3 4 5 6 7 8 10 12 Description Automatic answer setting Escape character setting Command line termination character setting Response formatting character setting Command line editing character setting Pause before blind dialling setting Connection completion timeout setting Command dial modifier time setting Automatic disconnect delay setting Escape prompt delay setting If a other than those
SARA-R4/N4 series - AT Commands Manual 2 General operation 2.1 Start up and initialization The characteristics of the boot of the cellular device vary from module to module and are described in the corresponding System Integration Manual; during this phase the module might be not responsive on the AT interface until all necessary SW modules have been installed (e.g. USB drivers); monitoring of the greeting text, where supported, can help in detecting the successful end of the boot phase.
SARA-R4/N4 series - AT Commands Manual 2.2.2 Set command A set command configures the preferred settings for the specified command. The set command is the only way to set the preferred settings in the DCE. For some commands it is possible to store the current settings in the profile or in the non volatile memory and retrieve them in another connection. 2.2.3 Read command A read command provides the current setting of the command parameters. It is used to find out the current command configuration. 2.2.
SARA-R4/N4 series - AT Commands Manual transmit the buffered URCs. Otherwise the collision of the URCs with the subsequent AT command is still possible. In case multiple AT interfaces are available, it should be advisable to use one of the different AT interfaces to manage all the user enabled URCs, while use the others ones to send AT commands and receive their responses. Anyway URCs related to external causes (e.g. RING) are issued on all interfaces. 2.2.
SARA-R4/N4 series - AT Commands Manual 3 IPC - Inter Processor Communication 3.1 Multiplexing mode +CMUX +CMUX Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Attributes Error reference +CME Error 3.1.1 Description Enables the multiplexing protocol control channel as defined in 3GPP TS 27.010 [46]. The command sets the parameters for the control channel.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number Number Number Description This parameter is ignored and the value 0 is always displayed in case of read command. Maximum frame size: • Allowed range is 1-1509. • The default value is 31. Acknowledgement timer in units of ten milliseconds. The allowed range is 1-255. This parameter is ignored and the value 253 is always set. Maximum number of re-transmissions: • Allowed range is 0-5.
SARA-R4/N4 series - AT Commands Manual 4 General 4.1 Manufacturer identification +CGMI +CGMI Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Attributes Error reference +CME Error 4.1.1 Description Text string identifying the manufacturer. 4.1.2 Syntax Type Action Syntax AT+CGMI Response Example u-blox AT+CGMI=? OK OK OK Test 4.1.
SARA-R4/N4 series - AT Commands Manual 4.3 Model identification +CGMM +CGMM Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 4.3.1 Description Text string identifying the model identification. 4.3.2 Syntax Type Action Syntax AT+CGMM Response Example LISA-U200 AT+CGMM=? OK OK OK Test 4.3.
SARA-R4/N4 series - AT Commands Manual 4.5.2 Syntax Type Action Syntax AT+CGMR Response Example 11.40 AT+CGMR=? OK OK OK Test 4.5.3 Defined values Parameter Type String Description Firmware version 4.6 Firmware version identification +GMR +GMR Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 4.6.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description It indicates the requested serial number type.
SARA-R4/N4 series - AT Commands Manual Type Syntax Modem and application version request ATI9 Response , OK Example ATI9 29.90,A01.00 OK 4.9.3 Defined values Parameter Type String String String Description Product type number Module modem version Module application version. Where not applicable the module provides "Undefined" 4.
SARA-R4/N4 series - AT Commands Manual 4.11 International mobile subscriber identification +CIMI +CIMI Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No - Error reference +CME Error 4.11.1 Description Request the IMSI (International Mobile Subscriber Identity). 4.11.2 Syntax Type Action Syntax AT+CIMI Response Example 222107701772423 AT+CIMI=? OK OK OK Test 4.11.
SARA-R4/N4 series - AT Commands Manual 4.13 Repeat last command A/ A/ Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 4.13.1 Description Repeats the previously executed command again. Only the A/ command cannot be repeated. If autobauding is active, the MT is not able to recognize the command and the command A/ cannot be used. 4.13.
SARA-R4/N4 series - AT Commands Manual 5 Mobile equipment control and status 5.1 Module switch off +CPWROFF +CPWROFF Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No < 40 s Error reference +CME Error 5.1.1 Description Switches off the MT. During shut-down current settings are saved in module's non-volatile memory.
SARA-R4/N4 series - AT Commands Manual 5.2.3 Defined values Parameter Type Number Description Selected functionality: • 0: sets the MT to minimum functionality (disable both transmit and receive RF circuits by deactivating both CS and PS services) • 1 (factory-programmed value): sets the MT to full functionality, e.g. from airplane mode or minimum functionality • 4: disables both transmit and receive RF circuits by deactivating both CS and PS services and sets the MT into airplane mode.
SARA-R4/N4 series - AT Commands Manual 5.3 Indicator control +CIND +CIND Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference +CME Error 5.3.1 Description Provides indication states related to network status, battery information and so on.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • "smsfull": indication that an SMS has been rejected with the cause of SMS storage full o 0: SMS storage not full o 1: SMS storage full • "gprs": PS indication status: o 0: no PS available in the network o 1: PS available in the network but not registered o 2: registered to PS o 65535: indication not available • "callsetup": call set-up: o 0: no call set-up o 1: incoming call not accepted or rejected o 2: outgoing call in dialling state o
SARA-R4/N4 series - AT Commands Manual 5.4.3 Defined values Parameter Type Number Description The unsigned integer (0 to 4095) is a bitmask representing the list of the indications active for +CIEV URC reporting. The bit position corresponds to the indicator order number (see the parameter of +CMER). The least significant bit is used for the first indicator.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number UBX-17003787 - R11 Description • 0: MT buffer of URCs defined within this command is cleared when 1...3 is entered • 1: MT buffer of URCs defined within this command is flushed to the DTE when 1...3 is entered (the OK final result code shall be given before flushing the codes). Indicates the indicator order number.
SARA-R4/N4 series - AT Commands Manual 5.6 Clock +CCLK +CCLK Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No NVM No - Error reference +CME Error 5.6.1 Description Sets and reads the real-time clock of the MT. 5.6.
SARA-R4/N4 series - AT Commands Manual Type Syntax Test AT+CSGT=? Response Example OK OK +CSGT: (list of supported s), +CSGT: (0-1),49 OK OK 5.7.3 Defined values Parameter Type String Number Number Description Greeting text. The factory-programmed value is the empty string. • 0: turn off the greeting text • 1: turn on the greeting text Maximum length of the parameter. 5.
SARA-R4/N4 series - AT Commands Manual 5.9 Report mobile termination error +CMEE +CMEE Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 5.9.1 Description Configures the formatting of the result code +CME ERROR: as an indication of an error relating to the functionality of the MT.
SARA-R4/N4 series - AT Commands Manual 6 Call control 6.1 Dial command D D Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M Syntax PIN required Settings saved Can be aborted Response time full Yes No Yes Up to 3 min Error reference +CME Error 6.1.1 Description Lists characters that may be used in a dialling string for making a call (voice, data or fax call) or controlling supplementary services in accordance with 3GPP TS 22.
SARA-R4/N4 series - AT Commands Manual 6.1.4 Notes • The subaddress feature is not supported by TOBY-L200-03S-00, TOBY-L210-03S-00, TOBY-L280-03S-00 and TOBY-L280-03A-00. TOBY-L200-03A-00, SARA-R404M / SARA-R410M-01B / SARA-R410M-02B / SARA-R410M-52B • Voice calls are not supported. 6.2 Call answer A A Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M Syntax PIN required Settings saved Can be aborted Response time full No No No < 20 s Error reference +CME Error 6.
SARA-R4/N4 series - AT Commands Manual 6.4 Automatic answer S0 S0 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M Syntax PIN required Settings saved Can be aborted Response time partial No Profile No - Error reference +CME Error 6.4.1 Description Controls the automatic answering feature of the DCE.
SARA-R4/N4 series - AT Commands Manual 7 Network service 7.1 Subscriber number +CNUM +CNUM Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No < 10 s Attributes Error reference +CME Error 7.1.1 Description Returns the MSISDNs related to this subscriber. If the subscriber has different MSISDN for different services, each MSISDN is returned in a separate line. MSISDN is read from the SIM. 7.1.
SARA-R4/N4 series - AT Commands Manual 7.2.2 Syntax Type Action Syntax AT+CSQ Response +CSQ: , Test AT+CSQ=? Example +CSQ: 2,5 OK OK +CSQ: (list of supported s),(list of supported s) OK OK 7.2.3 Defined values Parameter Type Number Number Description The allowed range is 0-31 and 99.
SARA-R4/N4 series - AT Commands Manual 7.3 Extended signal quality +CESQ +CESQ Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 7.3.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description • 255: not known or not detectable Reference Signal Received Power (RSRP): • 0: -141 dBm or less • 1..96: from -140 dBm to -45 dBm with 1 dBm steps • 97: -44 dBm or greater • 255: not known or not detectable 7.
SARA-R4/N4 series - AT Commands Manual URC), it is recommended to wait a few seconds before entering AT+COPS=2 in order to let the pending registration procedure (automatically triggered by the module in most cases) successfully end. The user should not rely only on the set command "OK" final result code as a confirmation that the network selection has been performed. To determine the current network registration status, +CEREG should be also checked. 7.4.
SARA-R4/N4 series - AT Commands Manual SARA-R410M-01B / SARA-R410M-02B • =8 is used for LTE Cat M1. 7.5 Radio Access Technology (RAT) selection +URAT +URAT Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No NVM No - Attributes Error reference +CME Error 7.5.1 Description Forces the selection of the Radio Access Technology (RAT) in the protocol stack.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number <2ndPreferredAct> Number Description • 8: LTE Cat.NB1 • 9: GPRS / eGPRS Indicates the preferred access technology; it is ignored if dual mode or tri mode are not selected. • 0: GSM / GPRS / eGPRS • 2: UTRAN • 3: LTE • 7: LTE Cat.M1 • 8: LTE Cat.NB1 • 9: GPRS / eGPRS Indicates the second preferred access technology; it is ignored if tri mode is not selected. • 0: GSM / GPRS / eGPRS • 2: UTRAN • 3: LTE • 7: LTE Cat.
SARA-R4/N4 series - AT Commands Manual The parameters , , are provided only if available. The read command provides the same information issued by the URC together with the current value of the parameter. The location information elements , and , if available, are returned only when =2 and the MT is registered with the network.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 5: UTRAN with HSUPA availability • 6: UTRAN with HSDPA and HSUPA availability • 7: E-UTRAN • 255: the current value is invalid 7.6.4 Notes The following is an overview of the values assumed by the parameter: • 0: a technical problem could have occurred, the user is requested to intervene. It is still possible to make emergency calls if some network is available.
SARA-R4/N4 series - AT Commands Manual 7.7 Network selection control +PACSP +PACSP Modules SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No - Attributes Error reference +CME Error 7.7.
SARA-R4/N4 series - AT Commands Manual The information text response of the read command reports only the current RAT (if any) parameters, determined by the parameter value. Table 4 lists the supported parameter values: Channel SARA-N4 SARA-R4 =0 * * =2 =3 =5 * * Table 4: parameter applicability 7.8.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK = 2, = 5: Example +UCGED: 2 5,1 5, OK OK = 0: +UCGED: MODE_5_DISABLED +UCGED: MODE_5_DISABLED OK OK = 5: +RSRP: 162,5110,"-075.00", +RSRP: ,, "", +UCGED: 2 +RSRQ: 162,5110,"-14.20", OK +RSRQ: ,, "", Test AT+UCGED=? OK +UCGED: (list of supported s) +UCGED: (0,2) OK OK 7.8.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number Number Description One byte routing area of the GERAN cell in hexadecimal format; FF if not known or not detectable. GERAN cell Received Signal Strength Indicator (RSSI) index as defined in 3GPP TS 45.008 [28]: • 0: less than -110 dBm • 1..62: from -110 to -48 dBm with 1 dBm steps • 63: -48 dBm or greater • 255: not known or not detectable Reserved for future use.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description • 1..48: from -24 dB to 0 dB with 0.5 dB steps • 49: 0 dB or greater • 255: not known or not detectable Reports the latest obtained value of the UMTS speech code. Allowed values: • 3: AMR NB (4.75 kb/s) • 4: AMR NB (5.15 kb/s) • 5: AMR NB (5.90 kb/s) • 6: AMR NB (6.70 kb/s) • 7: AMR NB (7.40 kb/s) • 8: AMR NB (7.95 kb/s) • 9: AMR NB (10.2 kb/s) • 10: AMR NB (12.2 kb/s) • 11: AMR WB (6.60 kb/s) • 12: AMR WB (8.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number Number Number Number Number Number Number String String Description • 1: IDLE • 2: ATTEMPT TO CONNECT • 3: CONNECTED • 4: LEAVING CONNECTED STATE • 5: ATTEMPT LEAVING E-UTRA • 6: ATTEMPT ENTERING E-UTRA • 255: not known or not detectable Rank Indicator value; 255 if not known or not detect
SARA-R4/N4 series - AT Commands Manual 7.9.2 Syntax Type Set Syntax AT+VZWAPNE=,, ,,, , Response OK Example AT+VZWAPNE=1,1,"VZWIMS", "IPv6","LTE","Enabled",0 Read AT+VZWAPNE? [+VZWAPNE: ,, ,,, [..
SARA-R4/N4 series - AT Commands Manual 7.10 Read RSRP values +VZWRSRP +VZWRSRP Modules Attributes SARA-R404M Syntax full PIN required No Settings saved Can be aborted No No Response time - Error reference +CME Error 7.10.1 Description Returns the RSRP (Reference Signal Received Power) values for all LTE cells which the module is measuring. 7.10.2 Syntax Type Read Syntax AT+VZWRSRP? Response +VZWRSRP: Example +VZWRSRP: [,,[, ,,[, ...
SARA-R4/N4 series - AT Commands Manual 7.12 eDRX setting +CEDRXS +CEDRXS Modules SARA-R410M-02B SARA-R410M-52B SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes NVM No Attributes Response time - Error reference +CME Error 7.12.1 Description Configures the UEs extended discontinuous reception (eDRX) parameters. The command controls whether the UE wants to apply the eDRX or not, as well as the requested eDRX value for each specified type of radio access technology.
SARA-R4/N4 series - AT Commands Manual Parameter Type String Description The paging time window refers to bit 8 to 5 of octet 3 of the extended DRX parameters information element, half a byte in a 4 bit format. For the coding and the value range, see the extended DRX parameters information element in Table 10 .5.5.32 of 3GPP TS 24.008 [12]. 7.12.4 Notes SARA-R4 / SARA-N4 • Only one is active at any given time.
SARA-R4/N4 series - AT Commands Manual 7.14 Set MNO profile +UMNOPROF +UMNOPROF Modules Attributes SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes NVM No Response time - Error reference +CME Error 7.14.1 Description Automatically configures the module to be compliant to the requirements of various Mobile Network Operators.
SARA-R4/N4 series - AT Commands Manual 7.15 Band selection bitmask +UBANDMASK +UBANDMASK Modules SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Attributes full Yes NVM No Response time - Error reference +CME Error 7.15.1 Description Sets the supported 4G LTE bands for different Radio Access Technologies (RATs). The bands supported are set by means of a bitmask where each bit in an 8 byte integer corresponds to a 4G LTE band.
SARA-R4/N4 series - AT Commands Manual 8 Security 8.1 Enter PIN +CPIN +CPIN Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No < 10 s Attributes Error reference +CME Error 8.1.1 Description Enter PIN. If no PIN request is pending, the corresponding error code is returned.
SARA-R4/N4 series - AT Commands Manual AT+COPS=0 ERROR • To change the PIN the user must use the AT+CPWD="SC",, command (see Chapter 8.3 for details). Example: AT+CPWD="SC","1234","4321" 8.2 Facility lock +CLCK +CLCK Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No Yes Up to 3 min Error reference +CME Error 8.2.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • "AI": BAIC (Bar All Incoming Calls) • "IR": BIC-Roam (Bar Incoming Calls when Roaming outside the home country) • "AB": All Barring services (applicable only for =0) • "AG": All outGoing barring services (applicable only for =0) • "AC": All inComing barring services (applicable only for =0) • "CS": CNTRL (lock CoNTRoL surface (e.g. phone keyboard)) (see the 3GPP TS 27.
SARA-R4/N4 series - AT Commands Manual 8.3.3 Defined values Parameter Type String String String Number Description "P2" SIM PIN2; see the +CLCK command description for other values Old password New password Length of password (digits) 8.3.4 Notes • If the PIN is blocked, an error result code will be provided when attempting to change the PIN code if the PIN check is disabled through AT+CLCK command.
SARA-R4/N4 series - AT Commands Manual 9 Short Messages Service 9.1 Introduction For a complete overview of SMS, see 3GPP TS 23.040 [8] and 3GPP TS 27.005 [16]. In case of errors all the SMS related AT commands return an error result code as defined in Appendix A.2. 9.1.1 Class 0 SMS The storing of a class 0 SMS depends on the module series: • SARA-R4 / SARA-N4 - not stored. 9.1.
SARA-R4/N4 series - AT Commands Manual 9.2.2 Syntax Type Set Syntax AT+CSMS= Read AT+CSMS? Test Response +CSMS: ,, Example AT+CSMS=1 OK +CSMS: 1,1,1 +CSMS: ,,, OK +CSMS: (list of supported s) AT+CSMS=? OK +CSMS: 0,1,1,1 OK +CSMS: (0-1) OK OK 9.2.3 Defined values Parameter Type Number Number Number Number Description • 0: see 3GPP TS 23.040 [8] and 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response Read AT+CPMS? Test AT+CPMS=? Example OK +CPMS: ,,, +CPMS: "MT",4,350,"MT",4,350, ,,, "MT",4,350 ,, OK OK +CPMS: (list of supported +CPMS: ("MT","ME","SM","BM", s),(list of supported "SR"),("MT","ME","SM"),("MT","ME", s),(list of supported "SM") s) OK OK 9.3.
SARA-R4/N4 series - AT Commands Manual 9.4.2 Syntax Type Set Syntax AT+CMGF=[] Response OK Example AT+CMGF=1 Read AT+CMGF? +CMGF: OK +CMGF: 1 Test AT+CMGF=? OK OK +CMGF: (list of supported s) +CMGF: (0-1) OK OK 9.4.3 Defined values Parameter Type Number Description Indicates the format of messages used with send, list, read and write commands and URCs resulting from receiving SMSes messages: • • 0 (default and factory-programmed value): PDU mode 1: text mode 9.
SARA-R4/N4 series - AT Commands Manual 9.6 Restore settings +CRES +CRES Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No < 10 s Error reference +CMS Error 9.6.1 Description Restores message service settings from a non-volatile memory (NVM) to the current active memory (RAM).
SARA-R4/N4 series - AT Commands Manual Type Syntax Response +CMT: ,[], [,,,, ,,, ] PDU mode (+CMGF=0): +CMT: , Text mode (+CMGF=1): URC +UCMT: , ,,[], [],[], ,[],[,,], PDU mode (+CMGF=0): +UCMT: +CBMI: , Text mode (+CMGF=1): URC URC +CBM: ,
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number String Number Number String String String String UBX-17003787 - R11 Number Number Number Number Number Description • 1: if the CBM is stored in the MT, an indication of the used memory location is routed to DTE using the +CBMI URC • 2: new CBMs are routed directly to the DTE using the +CBM URC • 3: class 3 CBMs are routed directly to D
SARA-R4/N4 series - AT Commands Manual Parameter - Type Number Number String Number String Number Number Number Number String Number Number Number Number Description First octet of the SMS TPDU (see 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual 9.8.2 Syntax Type Set Syntax Text mode (+CMGF=1): AT+CMGR= Response SMS-DELIVER +CMGR: ,,[], [,,,,, ,,] OK SMS-SUBMIT +CMGR: ,,[][, ,,,,[], ,,] Example AT+CMGR=303 +CMGR: "REC READ", "+393488535999",,"07/04/05,18:0 2:28+08",145,4,0,0,"+393492000 466",145,93 You have a missed called. Free information provided by your operator.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number String String Number Number Description Type of address of - octet in Number format (for more details see the 3GPP TS 24.008 [12]); default 145 when string includes '+', otherwise default 129 Two meanings: • in text mode: number of characters • in PDU mode: PDU's length in octets without the Service Center's address.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number String Description 3GPP TS 23.041 [9] CBM Page Parameter bits 0-3 in integer format Protocol data unit: each 8-bit octet is presented as two IRA character long hexadecimal numbers, e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65) 9.
SARA-R4/N4 series - AT Commands Manual 9.10 List message +CMGL +CMGL Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time Error reference full Yes No No Up to 3 min (<1 +CMS Error s for prompt ">" when present) 9.10.1 Description Returns SMS messages with status value from message storage to the DTE.
SARA-R4/N4 series - AT Commands Manual Type Test Syntax AT+CMGL[=] AT+CMGL=? Response +CMGL: ,,[], Example +CMGL: 305,1,,57 079193432900 1185440ED0D637396C7EBBCB0 000909092708024802A050 003000303DEA0584CE60 [+CMGL: ,,[], 205D974791994769BDF3A90 ] DB759687E9F534FD0DA2C9603419 [...] OK +CMGL: (list of supported s) +CMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT", "ALL") OK OK 9.10.
SARA-R4/N4 series - AT Commands Manual Parameter - Type Number Number String Number String Number Number Number Number Number Number String Number Description First octet of the SMS TPDU (see 3GPP TS 23.040 [8]) Message reference Recipient address field Type of address of - octet Discharge time in format "yy/MM/dd,hh:mm:ss+zz"; the time zone is expressed in steps of 15 minutes.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number String String Description Message reference Two meanings: • in text mode: number of characters • in PDU mode: PDU's length in octets without the Service Center's address. In example 039121430100038166F6000004E374F80D: is a PDU with Service Center's number +1234, that generates the address 03912143 (4 octets). Thus in this case =13.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number or String Description of the currently selected TE character set (see the +CSCS AT command); type of address given by TP-Originating-Address Type-of-Address octet (see the 3GPP TS 24.011 [13]); see the parameter for the default value TP-Destination-Address Type-of-Address octet (see the 3GPP TS 24.
SARA-R4/N4 series - AT Commands Manual 9.14 Set text mode parameters +CSMP +CSMP Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No < 10 s Error reference +CMS Error 9.14.1 Description Selects values for additional parameters needed when an SMS is sent to the network or placed in a storage when text format message mode is selected. For more details see the 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual 9.15 Delete message +CMGD +CMGD Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial Yes No No < 55 s Error reference +CMS Error 9.15.1 Description Deletes the message from the preferred message storage , if = 0 or not present, in location . Otherwise the messages are deleted following the rules specified by .
SARA-R4/N4 series - AT Commands Manual RAM is displayed. At the power on, the MT reads the SMSC address in the SIM card and the same value is set in RAM. 9.16.2 Syntax Type Set Syntax AT+CSCA=[,] Response OK Example AT+CSCA="0170111000",129 Read AT+CSCA? +CSCA: , OK +CSCA: "",129 Test AT+CSCA=? OK OK OK 9.16.3 Defined values Parameter Type String String Description Service center address Type of address of (for more details refer to 3GPP TS 24.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response ,,][,, ,,[] Example OK OK SMS-STATUS-report +UCMGR:,,,[], []]- , OK SMS-COMMAND +UCMGR: ,,[,, [],[],[], []] OK CBM storage +UCMGR: ,,, ,, Test AT+UCMGR=? OK OK 9.17.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description o if TE character set is "HEX": ME/TA converts each 7-bit character of GSM 7 bit default alphabet into two IRA character long hexadecimal number (e.g. character Æ (GSM 7 bit default alphabet 28) is presented as 1C (IRA 49 and 67)) • if indicates that 8-bit or UCS2 data coding scheme is used, or indicates that 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual 9.18 List concatenated message +UCMGL +UCMGL Modules Attributes SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes No No Response time Error reference Up to 3 min (<1 +CMS Error s for prompt ">" when present) 9.18.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK CBM storage: +UCMGL: ,,, ,, Example [+UCMGL: ,,, ,,,[...]] Test AT+UCMGL=? OK +UCMGL: (list of supported s) +UCMGL: ("REC UNREAD","REC READ","STO UNSENT","STO SENT", OK "ALL ") OK 9.18.
SARA-R4/N4 series - AT Commands Manual Parameter Type - String Number Number Number String Number String Number Number Number Number Number Number Number Description if indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number Destination address Type of address of - octet First octet of the SMS TPDU (see 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual 9.19.
SARA-R4/N4 series - AT Commands Manual 9.20.3 Defined values Parameter Type String String Number Number String Description 3GPP TS 23.040 [8] TP-Destination-Address Address-Value field in string format; BCD numbers (or GSM 7 bit default alphabet characters) are converted to characters of the currently selected TE character set (refer command +CSCS in 3GPP TS 27.007 [2]); type of address given by 3GPP TS 23.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 1: keep enabled until the time between the response of the latest message send command (such as +CMGS) and the next send command exceeds 5 s, then close the link and switch automatically back to 0 • 2: keep permanently enabled. The link is closed after each send sequence, but is not switched back to 0 9.
SARA-R4/N4 series - AT Commands Manual 9.23 Terminating data reporting via control plane +CRTDCP +CRTDCP Modules Attributes SARA-N4 Syntax full PIN required No Settings saved Can be aborted No No Response time - Error reference +CME Error 9.23.1 Description Configures the terminating data reporting from network to the DTE via the control plane. Data is identified by the local context identification parameter . When enabled, the URC is sent from the MT upon reception of data from network. 9.23.
SARA-R4/N4 series - AT Commands Manual 10 V24 control and V25ter 10.1 Introduction These commands, unless specifically stated, do not implement set syntax using "=", read ("?"), or test ("=?"). If such commands are used, the "+CME ERROR: unknown" or "+CME ERROR: 100" error result code is provided (depending on the +CMEE AT command setting). 10.
SARA-R4/N4 series - AT Commands Manual 10.3.3 Defined values Parameter Type Number Description • • • 0: the DCE ignores circuit 108/2 1 (default value and factory-programmed value): upon an ON-to-OFF transition of circuit 108/2, the DCE enters online command state and issues an OK result code 2: upon an ON-to-OFF transition of circuit 108/2, the DCE performs an orderly cleardown of the call. The automatic answer is disabled while circuit 108/2 remains OFF 10.3.
SARA-R4/N4 series - AT Commands Manual 10.4 DSR override &S &S Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No Profile No - Error reference +CME Error 10.4.1 Description Selects how the module will control RS232 circuit 107 - Data Set Ready (DSR). 10.4.2 Syntax Type Action Syntax AT&S[] Response OK Example 10.4.
SARA-R4/N4 series - AT Commands Manual • • • • Set the parameter of AT&K command to 0 (flow control disabled) or 4, 5 or 6 (software flow control) when the RTS and CTS lines are not physically connected. The software flow control (XON/XOFF) setting is not allowed on the USB interfaces, on the SPI interface and on a multiplexer channel. See the Multiple AT command interfaces for all the behavior differences in respect to the supported interfaces.
SARA-R4/N4 series - AT Commands Manual To overcome this situation, the ACCM negotiation handler should combine the value received in a Configure-Nak via a logical bitwise OR operation with the last configure-request value it sent. This result should then be sent in the next Configure-Request message.
SARA-R4/N4 series - AT Commands Manual 10.6.3 Defined values Parameter Type Number Description • • • • • • • 0: auto detect 1: 8 data 2 stop 2: 8 data 1 parity 1 stop 3: 8 data 1 stop 4: 7 data 2 stops 5: 7 bit, 1 parity, 1 stop 6: 7 bit, 1 stop Number • • 0: odd 1: even 10.6.4 Notes SARA-R4 • Automatic frame recognition is not supported ( cannot be set to 0). • The only supported values are = 3 and = 1. 10.
SARA-R4/N4 series - AT Commands Manual 10.7.3 Defined values Parameter Type Number Description • • • 0: none 1: DC1/DC3 on circuit 103 (XON/XOFF) 2 (default and the factory-programmed value): circuit 105 (RTS) Number • • • 0: none 1: DC1/DC3 on circuit 104 (XON/XOFF) 2 (default and the factory-programmed value): circuit 106 (CTS) 10.7.4 Notes • and parameters must be provided with the same value in pairs (only (0, 0), (1,1) and (2,2) are allowed.
SARA-R4/N4 series - AT Commands Manual 10.9 UART data rate configuration +IPR +IPR Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No Profile No - Error reference +CME Error 10.9.1 Description Specifies the data rate at which the DCE accepts commands on the UART interface. The full range of data rates depends on HW or other criteria.
SARA-R4/N4 series - AT Commands Manual 10.10 Return to on-line data state O O Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No - Attributes Error reference +CME Error 10.10.1 Description Causes the DCE to return to online data state and issue a CONNECT or CONNECT (based on ATX command) intermediate result code on DTE.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK Example OK 10.11.3 Defined values Parameter Type Number Description Range 1 to 255. The answer to the read command is in "xxx" format. The default and the factory-programmed value is 43 (ASCII '+'). 10.11.4 Notes SARA-R4 / SARA-N4 • The following table shows how the ATS2 command works for different data call scenarios.
SARA-R4/N4 series - AT Commands Manual 10.13 Response formatting character S4 S4 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No Profile No - Error reference +CME Error 10.13.1 Description Sets a value representing the decimal IRA5 value of the character generated by the DCE as part of the header, trailer and terminator for result codes and information text, along with the S3 setting.
SARA-R4/N4 series - AT Commands Manual 10.15 Pause before blind dialling S6 S6 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference +CME Error 10.15.1 Description Specifies the time in seconds that the DCE waits between connecting to the line and dialling, when the dial tone is not implemented or enabled.
SARA-R4/N4 series - AT Commands Manual 10.17 Command dial modifier time S8 S8 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference +CME Error 10.17.1 Description Specifies the amount of time, in seconds, that the DCE shall pause during dialling, when a ',' (comma) dial modifier is encountered in a dial string. The command has no effect. 10.17.
SARA-R4/N4 series - AT Commands Manual 10.19 Escape prompt delay (EPD) S12 S12 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference +CME Error 10.19.
SARA-R4/N4 series - AT Commands Manual 10.21 Result code suppression Q Q Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No Profile No - Error reference +CME Error 10.21.1 Description Determines if DCE transmits result codes to the DTE or not. When result codes are being suppressed, no portion of any intermediate, final or URC is transmitted.
SARA-R4/N4 series - AT Commands Manual 10.23 Result code selection and call progress monitoring control X X Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No Profile No - Error reference +CME Error 10.23.1 Description In a CS data call, determines how the DCE transmits to the DTE the CONNECT result code. 10.23.2 Syntax Type Set Syntax ATX[] Response OK Example ATX1 OK 10.23.
SARA-R4/N4 series - AT Commands Manual 10.25 Set to factory defined configuration &F &F Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 10.25.1 Description Resets the current profile to factory-defined defaults. Other NVM settings, not included in the profiles, are not affected.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response Example 00, +CRC:000, +IPR:0, +COPS:0,0, FFFFF, +ICF:3,1, +UPSV: 0, +CMGF:0 , +CNMI:1,0,0,0,0, +USTS: 0 STORED PROFILE 1: &C1, &D1, &S1, &K3, E1, Q0, V1, X4, S00:000, S0 2:043, S03:013, S04:010, S05:00 8, S07:060, +CBST:007, 000, 001, +CRLP:061, 061, 048, 006, +CR:0 00, +CRC:000, +IPR:0, +COPS:0,0, FFFFF, +ICF:3,1, +UPSV: 0, +CMGF:0 , +CNMI:1,0,0,0,0, +USTS: 0 OK 10.26.3 Notes SARA-R4 / SARA-N4 • Only the ACTIVE PROFILE is available.
SARA-R4/N4 series - AT Commands Manual 11 SIM management 11.1 Generic SIM access +CSIM +CSIM Modules SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes No No Attributes Response time - Error reference +CME Error 11.1.1 Description Allows direct control of the SIM by a distant application on the TE. This command transparently transmits the to the SIM via the MT. The is returned in the same manner to the TE.
SARA-R4/N4 series - AT Commands Manual Type Syntax Test AT+CLAN=? Response OK OK Example OK 11.2.3 Defined values Parameter Type String Description It is a two-letter abbreviation of the language. The language codes, as defined in ISO 639, consists of two characters, e.g. "en", "it" etc 11.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 13: CSD call active, (U)SIM toolkit REFRESH proactive command delayed till call release 11.3.4 Notes • • =9 and 10 will not be reported when dedicated (+CFUN=6) or raw (+CFUN=9) mode is active.
SARA-R4/N4 series - AT Commands Manual 12 SIM toolkit 12.1 Introduction SIM Application Toolkit (STK) is the 3GPP standard feature that allows the Subscriber Identity Module (SIM) to handle the DCE, also by giving commands such as displaying menus and/or asking for user input, and control its access to the network. Once the SIM toolkit interface has been enabled via AT+CFUN command, the DTE is notified SIM toolkit commands and events and can interact with the SIM through appropriate STK AT commands.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Description • 2: OPEN CHANNEL, CLOSE CHANNEL and CHANNEL STATUS EVENT status indications enabled Indicates the event download's tag or proactive command's tag.
SARA-R4/N4 series - AT Commands Manual 12.4 Write the USAT profile +CUSATW +CUSATW Modules SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes NVM No Attributes Response time - Error reference +CME Error 12.4.1 Description Writes a USAT terminal profile to the profile storage location. If the profile storage parameter is omitted in the set command, it resets the profiles for all the supported profile storage values to factory-programmed setting.
SARA-R4/N4 series - AT Commands Manual Type Read Syntax AT+UCUSATA? Response +UCUSATA: Example +UCUSATA: 0 Test AT+UCUSATA=? OK +UCUSATA: (list of supported s) OK +UCUSATA: (0-7) OK OK +CUSATP: +CUSATEND URC URC 12.5.3 Defined values Parameter Type Number Description Bitmask representing which URCs are activated. String See Table 10 for the meaning of each bit. The factory-programmed value is 0.
SARA-R4/N4 series - AT Commands Manual 13 Packet switched data services 13.1 PDP contexts and parameter definition 13.1.1 Primary and secondary PDP contexts A PDP context can be either primary or secondary. In LTE, PS data connections are referred to as EPS bearers: EPS bearers are conceptually equivalent to the legacy PDP contexts, which are often referred to for sake of simplicity. Similarly to a PDP context, the EPS bearer can be a default (primary) or dedicated (secondary) one.
SARA-R4/N4 series - AT Commands Manual 13.1.3 Parameter definition 13.1.3.1 The Access Point Name (APN) is a string parameter, which is a logical name, valid in the current PLMN's domain, used to select the GGSN (Gateway GPRS Support Node) or the external packet data network to be connected to. The APN can be omitted: this is the so-called "blank APN" setting that may be suggested by network operators (e.g.
SARA-R4/N4 series - AT Commands Manual 13.2 PPP LCP handshake behaviour When a data call is initiated by means of D* AT command, the module switches to PPP mode just after the CONNECT intermediate result code. The first step of the PPP procedure is the LCP handshake, in this phase the behaviour of 2G products differs from 3G products and 4G products.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response s),(list of supported s)[,(list of supported s)]] Example OK 13.3.
SARA-R4/N4 series - AT Commands Manual Command AT+CGDCONT=2,"IP","internet" AT+CGDCONT=1,"IP","STATREAL" AT+CGDCONT=3,"IP","PAP: tim.ibox.it" AT+CGDCONT=253,"IP","internet" AT+CGDCONT? Response OK OK OK +CME ERROR: operation not allowed +CGDCONT: 2,"IP","internet","0.0.0.0",0,0 Description Define allowed PDP contexts Define allowed PDP contexts Define allowed PDP contexts Define out of range PDP contexts Read command +CGDCONT: 1,"IP","STATREAL","0.0.0.0",0 ,0 +CGDCONT: 3,"IP","tim.ibox.it","0.0.0.
SARA-R4/N4 series - AT Commands Manual Type Syntax AT+UPSD= Response Example +UPSD: ,0, +UPSD: 0,0,0 +UPSD: ,1,... +UPSD: 0,2,"username" +UPSD: ,x, +UPSD: 0,4,"0.0.0.0" OK ... +UPSD: 0,19,0 OK 13.4.
SARA-R4/N4 series - AT Commands Manual Parameter UBX-17003787 - R11 Type Description o 0 (factory-programmed value): subscribed o 1: high o 2: normal o 3: low • 11: QoS delay - the parameter selects the delay class: o 0 (factory-programmed value): subscribed o 1: class 1 o 2: class 2 o 3: class 3 o 4: best effort • 12: QoS reliability - the parameter selects the reliability class: o 0 (factory-programmed value): subscribed o 1: class 1 (Interpreted as class 2) o 2: class 2 (GTP U
SARA-R4/N4 series - AT Commands Manual Parameter UBX-17003787 - R11 Type Description • 22: 3G QoS extended guaranteed downlink bit rate - is the value for the extended guaranteed downlink bit rate in kb/s. The factory-programmed value is 0. • 23: 3G QoS extended maximum downlink bit rate - is the value for the extended maximum downlink bit rate in kb/s. The factory-programmed value is 0.
SARA-R4/N4 series - AT Commands Manual Parameter UBX-17003787 - R11 Type Description • 36: 3G minimum QoS delivery order - selects the acceptable value for the delivery order: o 0 (factory-programmed value): subscribed o 1: enable o 2: disable • 37: 3G minimum QoS erroneous SDU delivery - selects the acceptable value for the erroneous SDU delivery: o 0 (factory-programmed value): subscribed o 1: no detection o 2: enable o 3: disable • 38: 3G minimum QoS extended guaranteed downli
SARA-R4/N4 series - AT Commands Manual Parameter Type Description o 1: conversational o 2: streaming o 3: interactive o 4: background • 50: 3G minimum QoS traffic priority - selects the acceptable value for the traffic priority: o 0 (factory-programmed value): subscribed o 1: priority 1 o 2: priority 2 o 3: priority 3 • 51: 3G Minimum QoS transfer delay - is the value for the transfer delay in milliseconds. The factory-programmed value is 0.
SARA-R4/N4 series - AT Commands Manual 13.5.2 Syntax Type Set Syntax AT+CGATT=[] Response OK Example AT+CGATT=1 Read AT+CGATT? +CGATT: OK +CGATT: 1 Test AT+CGATT=? OK +CGATT: (list of supported s) OK +CGATT: (0-1) OK OK 13.5.3 Defined values Parameter Type Number Description Indicates the state of GPRS attachment: • 0: detached • 1 (default value): attached 13.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description • 0: deactivated • 1: activated See . 13.6.4 Notes SARA-R4 / SARA-N4 • If is not defined, the command activates or deactivates all the defined PDP contexts. 13.6.5 Examples Examples of usage of +CGDCONT, +CGACT, +CGPADDR command: Command sent by the DTE AT+CMEE=2 DCE response OK AT+COPS=0 AT+COPS? OK +COPS: 0,0,"vodafone IT" AT+CGDCONT=1,"IP","web.omnitel.
SARA-R4/N4 series - AT Commands Manual Command sent by the DTE AT+CGPADDR=2 DCE response +CGPADDR: 2, "10.159.135.60" AT+CGACT=0 OK OK AT+CGPADDR=2 +CGPADDR: 2, "0.0.0.0" AT+CGPADDR=3 OK +CGPADDR: 3, "0.0.0.0" AT+CGDCONT? OK +CGDCONT: 1,"IP","web.omnitel.it","0.0.0.0",0,0 Description Show the address of PDP context 2 Deactivate all of defined PDP contexts Show the address of PDP context 2 Show the address of PDP context 3 +CGDCONT: 3,"IP","internet","0.0.0.0",0,0 +CGDCONT: 2,"IP","mms.vodafone.
SARA-R4/N4 series - AT Commands Manual If the command is accepted and the preliminary PS procedures have succeeded, the "CONNECT" intermediate result code is returned, the MT enters the V.25ter online data state and the PPP L2 protocol between the MT and the DTE is started. The data session is terminated by one of the following events: • sending ~+++. • via a DTR transition from ON to OFF. • sending an LCP Terminate Request.
SARA-R4/N4 series - AT Commands Manual • If FDN is enabled and FDN check for PS data call is supported by the module, to perform a GPRS dial-up one of the following entries must be stored in the FDN phonebook: *99#, *99*#, *99**# or *99***#. SARA-R4 / SARA-N4 • The local dial-up feature is not supported. 13.
SARA-R4/N4 series - AT Commands Manual Type URC Syntax Response Example +CGEV: ME PDN ACT [, +CGEV: NW CLASS "CC" [,]] +CGEV: ME ACT ,, +CGEV: ME PDN DEACT +CGEV: ME DEACT , ,[] +CGEV: ME DEACT,,,0 +CGEV: ME DEACT ,, +CGEV: ME MODIFY , , +CGEV: ME DETACH +CGEV: ME CLASS +CGEV: NW PDN ACT [, ] +CGEV: NW ACT ,, +CG
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number String Description This parameter is only locally valid on the interface TE-MT.
SARA-R4/N4 series - AT Commands Manual • • +CGREG: if =1 and there is a change in the GPRS network registration status in GERAN/UTRAN +CGREG: [,,[,,]] if =2 and there is a change of the network cell in GERAN/ UTRAN The parameters , , , are provided only if available. The read command provides the same information issued by the URC together with the current value of the parameter.
SARA-R4/N4 series - AT Commands Manual Parameter Type String Description • 0: GSM • 1: GSM COMPACT • 2: UTRAN • 3: GSM with EDGE availability • 4: UTRAN with HSDPA availability • 5: UTRAN with HSUPA availability • 6: UTRAN with HSDPA and HSUPA availability • 255: the current value is invalid One byte routing area in hexadecimal format 13.10.
SARA-R4/N4 series - AT Commands Manual 13.12.2 Syntax Type Set Syntax AT+CEMODE=[] Response OK Example AT+CEMODE=1 Read AT+CEMODE? +CEMODE: OK +CEMODE: 1 Test AT+CEMODE=? OK +CEMODE: (list of supported 's) OK +CEMODE: (0-3) OK OK 13.12.3 Defined values Parameter Type Number Description Mode configuration: • 0: PS mode 2 of operation.
SARA-R4/N4 series - AT Commands Manual • • • +CEREG: [,[],[],[][,,]] when =3 and the value of changes +CEREG: [,[],[],[][,,[,[],[]]]] when =4 if there is a change of the network cell in E-UTRAN +CEREG: [,[],[],[][,[],[][,[],[]]]] when =5 and the value of changes The parameters , , , ,
SARA-R4/N4 series - AT Commands Manual Parameter Type String String Number Number Number String String Description • 8: attached for emergency bearer services only (see 3GPP TS 24.008 [12] and 3GPP TS 24.
SARA-R4/N4 series - AT Commands Manual 13.14.2 Syntax Type Set Syntax AT+CGDEL=[] Test AT+CGDEL=? Response +CGDEL: [,[,...]] Example AT+CGDEL=2 OK +CGDEL: 2 OK OK OK 13.14.3 Defined values Parameter Type Number Description See 13.
SARA-R4/N4 series - AT Commands Manual 13.15.4 Notes • • In a PPP dial-up scenario, the authentication parameters set by the +UAUTHREQ command are overwritten whenever the host provides a new setting via the PPP authentication protocol (PAP or CHAP). The and parameters must be set to an empty string if the authentication type is not set (=0). SARA-R4 / SARA-N4 • =3 is not supported. 13.
SARA-R4/N4 series - AT Commands Manual 13.17 Enable/Disable data when roaming +UDCONF=76 +UDCONF=76 Modules Attributes SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full Yes NVM No Response time - Error reference +CME Error 13.17.1 Description Configures the PDP to enable or disable when roaming. When set to disabled, the PDP will not be able to send data when roaming on a network. The configuration will be effective at the next power on.
SARA-R4/N4 series - AT Commands Manual 14 System features 14.1 Firmware installation +UFWINSTALL +UFWINSTALL Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time Attributes full No No No - Error reference FW Install Error 14.1.1 Description Triggers the FW installation procedure, starting from the file (update binary file) stored in the module file system.
SARA-R4/N4 series - AT Commands Manual 14.2 Firmware update Over AT (FOAT) +UFWUPD +UFWUPD Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference FOAT Error 14.2.1 Description Triggers the firmware update using the Xmodem or Xmodem-1k protocol. The command syntax differs depending on the module series: see the corresponding subsection for the correct command handling.
SARA-R4/N4 series - AT Commands Manual 14.3 Antenna detection +UANTR +UANTR Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Attributes Error reference +CME Error 14.3.1 Description Measures the DC component of load of the cellular antenna (the GPS antenna is RFU). The antenna load is expressed in kOhm. 14.3.
SARA-R4/N4 series - AT Commands Manual • If the power saving is disabled (+UPSV: 0), the UART interface is always enabled and the module does not enter the idle mode 14.4.2 Syntax Type Set Syntax AT+UPSV= Response OK Example AT+UPSV=4 Read AT+UPSV? +UPSV: OK +UPSV: 0 Test AT+UPSV=? OK OK +UPSV: (list of supported s) +UPSV: (0,4) OK OK 14.4.3 Defined values Parameter Type Number Description Power saving configuration.
SARA-R4/N4 series - AT Commands Manual • • • 4G transmission of LTE SC-FDMA OFDM signal (5 MHz bandwidth) in the desired channel in TDD band and power level Receiving signal detection and RF level measurement on the desired 2G, 3G or 4G (LTE) channel Receiving signal detection at diversity or secondary antenna input and RF level measurement on the desired 2G, 3G or 4G (LTE) channel The command only accepts the parameter set supported by the specific module version.
SARA-R4/N4 series - AT Commands Manual Parameter .. Type Number Description Parameters needed for RX and TX test mode as reported in the table below. 14.5.5 Notes • • Check the corresponding module data sheet for the list of supported bands and Radio Access Technologies (RAT).
SARA-R4/N4 series - AT Commands Manual Parameter Description Range Default Notes range [139650-141589] LTE band TDD 41 EARFCN range [39650 - 41589] Table 11: parameter range Time Antenna diversity Minimum antenna -100 ÷ -20 RF level estimation • 1 ÷ 600000 0÷1 Average antenna -100 ÷ -20 RF level estimation Maximum antenna -100 ÷ -20 RF level estimation 1000 0 The "+CME ERROR: operation not supported" or "+CME ERROR: 4" error result code will be
SARA-R4/N4 series - AT Commands Manual Parameter Description Range Default Notes range [118000-118599] [118600-119199] [119200-119949] [119950-120399] [120400-120649] [120650-120749] [120750-121449] [121450-121799] [121800-122149] [123010-123179] [123180-123279] [123730-123849] [124000-124149] [124150-124449] [126040 - 126689] [126690 - 127039] [127210-127659] [136200-136349] [137750-138249] [138250-138649] [138650-139649] [139650-141589] LTE band FDD 1 FDD 2 FDD 3 FDD 4 FDD 5 FDD 6 FDD 7 FDD 8
SARA-R4/N4 series - AT Commands Manual Parameter Description Range Training sequence 0 ÷ 7 Default Notes ("+CME ERROR: operation not supported" or "+CME ERROR: 4" depending on the +CMEE AT command setting). 5 Training sequence to be used (to be changed only in case of link with network simulator, else use default) In 3G / 4G RAT the values is unused.
SARA-R4/N4 series - AT Commands Manual Command AT+UTEST=2,105230,,1 Response +UTEST: 105230,1000,1,-72,-71,-70 OK Description The module measures the antenna RX level at RX channel 5230 band FDD 13 for 1 s interval on the secondary antenna path.
SARA-R4/N4 series - AT Commands Manual Type Set Syntax AT+UTEST=10,[,[]] Response OK Example AT+UTEST=10,3,"0000001000000 300" OK Original configuration restoring Set AT+UTEST=10,0 OK AT+UTEST=10,0 OK Pins set definition Set AT+UTEST=10,2,[] OK AT+UTEST=10,2,"0000000C30000 0003000" OK Pins configuration Set AT+UTEST=10,3,[] OK AT+UTEST=10,3,"0000000420000 0001000" OK Output pins definition Set AT+UTEST=10,4,[
SARA-R4/N4 series - AT Commands Manual Parameter Type [] Description • 5: apply the setting change defined with = 2 / 3 / 4 and triggers the execution of the digital testing. Digital testing of the pins is possible only after the execution of the AT+UTEST=10,5 command.
SARA-R4/N4 series - AT Commands Manual Command AT+UTEST=0 Response OK Description Module exits from the test mode and normal pins configurations is restored. Table 15: Digital pins test command examples The digital pins can be configured as many times as needed by the testing process; AT+UTEST=10,2 command is not needed any more as the DUT is already in Interface initialised state. 14.
SARA-R4/N4 series - AT Commands Manual • the requested GPRS READY timer value in GERAN/UTRAN • the requested extended periodic TAU value in E-UTRAN • the requested Active Time value See the URCs provided by command +CEREG for the Active Time value and the extended periodic TAU value that are allocated to the UE by the network in E-UTRAN.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description GPRS Timer 3 IE in 3GPP TS 24.008 Table 10.5.163a/3GPP TS 24.008 [12]. See also 3GPP TS 23.682 [153] and 3GPP TS 23.401 [154]. • SARA-R4 - The factory-programmed value is 150 s. The default value is "01100000". One byte in an 8 bit format. Requested Active Time value (T3324) to be allocated to the UE.
SARA-R4/N4 series - AT Commands Manual Parameter Type String String Description Assigned extended periodic RAU (T3312) value allocated to the GERAN/UTRAN, one byte in an 8 bit format. For the coding and the value range, see the GPRS Timer 3 IE in 3GPP TS 24.008 [12] Assigned GPRS READY timer (T3314) value allocated to the UE in GERAN/UTRAN, one byte in an 8 bit format.
SARA-R4/N4 series - AT Commands Manual 14.10 Cancel LWM2M FOTA Download +ULWM2M=0 +ULWM2M=0 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes No No - Error reference - 14.10.1 Description When a LWM2M session is in progress and the firmware is being download to the device, the download can be canceled by issuing this command.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number / String Description • 0: module registration to uFOTA server disabled • 1 (factory-programmed and default value): module registration to uFOTA server enabled Timer for periodic connection to the uFOTA server (in seconds); the factoryprogrammed and default value is 604800 (7 days): • -1: never periodically connected to the uFOTA server • 1-4294967295: range in seconds for periodic connections Type and supported conten
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK +UULGASP: , URC Example +UULGASP: 0,1 14.12.3 Defined values Parameter Type Number String Number Number Number String Number Number Number Number Number Number Description Select the interrupt trigger.
SARA-R4/N4 series - AT Commands Manual 14.13 LWM2M host device information +UHOSTDEV +UHOSTDEV Modules Attributes SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full Yes NVM No - Error reference +CME Error 14.13.1 Description Sets the host identification, manufacturer model number and software version for the LWM2M device management. 14.13.
SARA-R4/N4 series - AT Commands Manual Type Test Syntax AT+URINGCFG=? Response +URINGCFG: (list of the supported s) Example +URINGCFG: (0-3) OK OK 14.14.
SARA-R4/N4 series - AT Commands Manual 15 GPIO 15.1 Introduction The section describes the AT commands used to configure the GPIO pins provided by u-blox cellular modules. 15.1.
SARA-R4/N4 series - AT Commands Manual When the SIM card detection functionality is enabled, the +CIND AT command reports the status. When the SIM card detection functionality is enabled, the status can be read with the +UGPIOR AT command. See the corresponding module system integration manual for the complete overview of all allowed configurations. 15.1.
SARA-R4/N4 series - AT Commands Manual Voltage VH VL 2s Time 100 ms Figure 2: GPIO pin progress for registered home network 2G 15.1.3.3 Registered home network 3G • Cyclic Output / High for 50 ms, Output / Low for 50 ms, Output / High for 50 ms, Output / Low for 2 s Voltage VH VL 2s Time 50 ms Figure 3: GPIO pin progress for registered home network 3G 15.1.3.
SARA-R4/N4 series - AT Commands Manual Voltage VH VL 2s Time 100 ms Figure 5: GPIO pin progress for registered roaming 2G 15.1.3.6 Registered roaming 3G • Cyclic Output / High for 50 ms, Output / Low for 50 ms, Output / High for 50 ms, Output / Low for 100 ms Voltage VH VL Time 50 ms 50 ms Figure 6: GPIO pin progress for registered roaming 3G 15.1.3.
SARA-R4/N4 series - AT Commands Manual Voltage VH VL Time Figure 8: GPIO pin progress for data transmission 15.1.3.9 Data transmission roaming • Cyclic Output / High for 800 ms, Output / Low for 200 ms Voltage VH Time VL 800 ms 200 ms Figure 9: GPIO pin progress for data transmission roaming 15.
SARA-R4/N4 series - AT Commands Manual • • • • • • SIM card detection Headset detection GSM Tx burst indication Module operating status indication Module functionality status indication Last gasp trigger For more details regarding the custom functions supported by the u-blox cellular modules and the factory-programmed settings, see GPIO functions and GPIO mapping. 15.2.2 Syntax Type Set Read Syntax AT+UGPIOC=,[,\] AT+UGPIOC? Response OK Example AT+UG
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Description • 15: UART (DSR, DTR, DCD e RI) interface • 16: Wi-Fi enable • 18: Ring indication • 19: Last gasp enable • 255: pad disabled GPIO output value (for output function =0 only): • 0 (default value): low • 1: high GPIO input value (for input function =1 only): • 0 (default value): no resistor activated • 1: pull up resistor active • 2: pull down resistor active 15.
SARA-R4/N4 series - AT Commands Manual 15.4 GPIO set command +UGPIOW +UGPIOW Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No < 10 s Attributes Error reference +CME Error 15.4.1 Description Sets ("writes") the output of the specified GPIO pin, but only if it is configured in output function (see the +UGPIOC AT command to set the pin as output). 15.4.
SARA-R4/N4 series - AT Commands Manual 16 File System 16.1 File tags 16.1.1 Description File system commands have the optional parameter that allows you to specify a file type when an AT command is issued, to inform the system what to do with it. Application specific files must be saved with the correct type tag, otherwise they are treated as common user files.
SARA-R4/N4 series - AT Commands Manual Tag "GNSS" "CALLSRV_EXT" Name GNSS files Emergency Call Number List (ECNL) management Specification This tag has to be used to store the firmware file for the internal GNSS receiver. This tag is used to manage the Emergency Call Number List (ECNL) file stored in NVM.
SARA-R4/N4 series - AT Commands Manual Type Set Syntax Response AT+UDWNFILE=,, OK "AUDIO_EXT" Example AT+UDWNFILE="audioconfig",4873, "AUDIO_EXT" OK 16.2.3 Defined values Parameter Type String Number String String Description File name. For file system file name and data size limits see File system limits. File size expressed in bytes. For file system file name and data size limits see File system limits.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response Example OK 16.3.3 Defined values Parameter ,.., Type Number Description Allowed values are: String String • 0 (default value): lists the files belonging to file type • 1: gets the free space for the specific file type • 2: gets the file size expressed in bytes, belonging to type (if specified) Specifies the application file type.
SARA-R4/N4 series - AT Commands Manual 16.5 Partial read file +URDBLOCK +URDBLOCK Modules Attributes SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted partial No No No Response time - Error reference +CME Error 16.5.1 Description Retrieves a file from the file system. Differently from +URDFILE command, this command allows the user to read only a portion of the file, indicating the offset and amount of bytes. 16.5.
SARA-R4/N4 series - AT Commands Manual 16.6.2 Syntax Type Set Syntax Response AT+UDELFILE=[,] OK Example AT+UDELFILE="filename","USER" OK 16.6.3 Defined values Parameter Type String String Description File name. For file system file name and data size limits see File system limits. The optional parameter specifies a different application file type. FILE TAGS table lists the allowed strings. 16.
SARA-R4/N4 series - AT Commands Manual 16.8 File system limits 16.8.1 Limits Here below are listed the maximum file name length, the maximum data size of the file system and the maximum number of files for the u-blox cellular modules.
SARA-R4/N4 series - AT Commands Manual 17 DNS DNS service requires the user to define and activate a connection profile, either PSD or CSD. When these command report an error which is not a +CME ERROR, the error class and code is provided through +USOER AT command. 17.1 Resolve name / IP number through DNS +UDNSRN +UDNSRN Modules Attributes SARA-R410M-52B SARA-N4 Syntax PIN required full No Settings saved Can be aborted No No Response time < 70 s Error reference TCP/UDP/IP Error 17.1.
SARA-R4/N4 series - AT Commands Manual Parameter Type String Description Once the result of DNS resolution becomes available, it is notified to the AT interface through the +UUDNSRN URC Resolved IP address corresponding to the specified domain name String Resolved domain name corresponding to the provided IP address Number Result code of DNS resolution: • 0: no error • -1: DNS resolution failed.
SARA-R4/N4 series - AT Commands Manual 18 Internet protocol transport layer 18.1 Introduction SARA-R4 / SARA-N4 Before using TCP/IP services, a connection profile must be defined and activated. The sockets can be managed independently and simultaneously over the same bearer (either PSD or CSD). AT commands for both reading and writing data on sockets are provided and the URC notifies the external application of incoming data and transmission result, no need for polling.
SARA-R4/N4 series - AT Commands Manual IPv4 address 0x10.0xE4.0x4C.0x22 Remarks Invalid address; dot-hexadecimal notation; decimals given as hexadecimal numbers Table 20: IPv4 address format examples 18.2.3 IPv6 Format: • • • • • • • 128 bits long represented in 8 groups of 16 bits each. The 16 bits of a group are represented as 2 concatenated hexadecimal numbers. The groups are separated by a colon character (:). The leading 0 in a group is supported.
SARA-R4/N4 series - AT Commands Manual 18.3.2 Syntax Type Set Test Syntax AT+USOCR=[,] Response +USOCR: Example AT+USOCR=17 OK +USOCR: 2 AT+USOCR=? +USOCR: (list of supported s),(list of supported s) OK +USOCR: (6,17),(1-65535) OK OK 18.3.3 Defined values Parameter Type Number Number Number Description • 6: TCP • 17: UDP Local port to be used while sending data. The range goes from 1 to 65535.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK Example 18.4.3 Defined values Parameter Type Number Number Number Description Socket identifier defined by the AT+USOCR command. The range goes from 0 to 6. • • 0 (default value): disable the SSL/TLS on the socket. 1: enable the SSL/TLS on the socket; a USECMNG profile can be specified with the parameter.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Description : signed 32 bit numeric parameter representing the milliseconds for "keepidle" option. The range is 0-2147483647. The default value is 7200000 (2 hours) • 65535: socket for socket level options may be: o 4: local address re-use. : numeric parameter, it configures the "local address re-use" option.
SARA-R4/N4 series - AT Commands Manual 18.6.2 Syntax Type Set Test Syntax Response AT+USOGO=,,[,] name> OK AT+USOGO=? +USOGO: (list of supported s),(list of supported s) Example AT+USOGO=0,0,2 +USOGO: 255 OK +USOGO: (0-6),(0,6,65535) OK OK 18.6.3 Defined values Parameter Type Number Number Description Socket identifier. The range goes from 0 to 6.
SARA-R4/N4 series - AT Commands Manual 18.6.4 Notes SARA-R4 / SARA-N4 • The setting = 6 (TCP protocol) and = 2 (keepidle option) is not supported. 18.7 Close Socket +USOCL +USOCL Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No < 120 s (except URC) Attributes Error reference +CME Error 18.7.1 Description Closes the specified socket, like the BSD close routine.
SARA-R4/N4 series - AT Commands Manual 18.8 Get Socket Error +USOER +USOER Modules SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Attributes Error reference TCP/UDP/IP Error +CME Error 18.8.1 Description Retrieves the last error occurred in the last socket operation, stored in the BSD standard variable error. 18.8.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response supported s),(list of supported s) OK +UUSOCO: , URC Example +UUSOCO: 2,0 18.9.3 Defined values Parameter Type Number String Number Number Number Description Socket identifier. The range goes from 0 to 6 Remote host IP address or domain name of the remote host. For IP address format reference see the IP addressing.
SARA-R4/N4 series - AT Commands Manual • • socket error use the +USOCTL=1 command. If the error code returned is 11, it means that the queue is full. If the connection is closed by the remote host, the +UUSOCL URC is not sent until all received data is read using the AT+USORD command. If AT+USOWR command is used in this situation, an error result code is returned.
SARA-R4/N4 series - AT Commands Manual • o After the command is sent, the user waits for the @ prompt. When it appears the stream of bytes can be provided. After the specified amount of bytes has been sent, the system provides the final result code. The feed process cannot be interrupted i.e. the return in the command mode can be effective only when the number of bytes provided is the declared one. o After the @ prompt reception, wait for a minimum of 50 ms before sending data.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response supported s),(list of supported s),"HEX data" Example +USOST: (0-6),"remote_host",(165535),(0-1024),"data" +USOST: (list of supported s),"remote_host",(list of supported s),(list of supported s),"data" +USOST: (0-6),"remote_host",(165535),(0-1024) OK +USOST: (list of supported s),"remote_host",(list of supported s),(list of supported s) OK 18.11.
SARA-R4/N4 series - AT Commands Manual 18.12 Read Socket Data +USORD +USORD Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No < 1 s (except URC) Error reference TCP/UDP/IP Error +CME Error 18.12.1 Description Reads the specified amount of data from the specified socket, like the BSD read routine. This command can be used to know the total amount of unread data.
SARA-R4/N4 series - AT Commands Manual • should rely on the info to count the received number of characters (after the starting quotation marks) especially if any protocol control characters are expected. If an application deals with letter and number characters only i.e. all of the expected characters are outside the [0x00, 0x1F] range and are not quotation marks, the AT+USORD response quotation marks can be assumed to identify the start and the end of the received data packet.
SARA-R4/N4 series - AT Commands Manual 18.13.4 Notes • • Each packet received from the network is stored in a separate buffer and the command is capable to read only a packet (or e portion of it) at time. This means that if is greater than the packet size, the command will return a maximum amount of data equal to the packet size, also if there are other packets in the buffer. The remaining data (i.e. the remaining UDP packets) can be read with further reads.
SARA-R4/N4 series - AT Commands Manual Type Test Syntax AT+USOLI=? Response +USOLI: (list of supported s),(list of supported s) OK +UUSOLI: ,, ,,, +UUSORF: , URC (TCP) URC (UDP) Example +USOLI: (0-6),(1-65535) OK +UUSOLI: 3,"151.63.16.7",1403,0, "82.89.67.164",200 +UUSORF: 1,967 18.14.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 1: HEX mode enabled 18.16 Set socket in Direct Link mode +USODL +USODL Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No <1s Error reference +CME Error 18.16.1 Description Establishes a transparent end to end communication with an already connected TCP or UDP socket via the serial interface.
SARA-R4/N4 series - AT Commands Manual 18.16.4.1 Timer Trigger (TT) The user can configure a timeout for sending the data. The timer starts every time a character is read from the serial interface. When the timer expires, buffered data is sent. The timer range is between 100 and 120000 ms; the special value 0 (zero) means that the timer is disabled. By default the timer trigger is disabled for TCP sockets and enabled with a value of 500 ms for UDP sockets.
SARA-R4/N4 series - AT Commands Manual 18.17.2 Syntax Type Set Syntax AT+UDCONF=2,, Read AT+UDCONF=2, Response OK Example AT+UDCONF=2,1,1024 OK +UDCONF: 2,, +UDCONF: 2,1,1024 OK OK 18.17.3 Defined values Parameter Type Number Description Socket identifier; used when changing the UDP Direct Link settings.
SARA-R4/N4 series - AT Commands Manual 18.19.2 Syntax Type Set Syntax AT+UDCONF=5,, Response OK Read AT+UDCONF=5, +UDCONF: 5,, OK Example AT+UDCONF=5,0,500 OK AT+UDCONF=5,0 +UDCONF: 5,0,500 OK 18.19.3 Defined values Parameter Type Number Number Description Socket identifier; used when changing the UDP Direct Link settings. The range is 0-6.
SARA-R4/N4 series - AT Commands Manual 18.21 Character trigger configuration for Direct Link +UDCONF=7 +UDCONF=7 Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 18.21.1 Description Sets the character trigger of the interested socket identifier for the data transmission enhanced Direct Link. 18.21.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description Valid range is 0-6 Enhanced Direct Link congestion timer (in milliseconds); valid range is 0, 1000-72000 0; the factory-programmed value is 60000, 0 means trigger disabled 18.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Description • 2: the socket is in SYN_SENT status • 3: the socket is in SYN_RCVD status • 4: the socket is in ESTABILISHED status • 5: the socket is in FIN_WAIT_1 status • 6: the socket is in FIN_WAIT_2 status • 7: the sokcet is in CLOSE_WAIT status • 8: the socket is in CLOSING status • 9: the socket is in LAST_ACK status • 10: the socket is in TIME_WAIT status If = 11, can assume these values: • N: the tot
SARA-R4/N4 series - AT Commands Manual 19 SSL/TLS 19.1 Introduction SSL/TLS provides a secure connection between two entities using TCP socket for communication (i.e. HTTP/ FTP server and HTTP/FTP client).
SARA-R4/N4 series - AT Commands Manual The certificates and private keys are kept in DER format and are not retrievable (i.e. cannot be downloaded from the module); for data validation purposes an MD5 hash string of the stored certificate or private key (stored in DER format) can be retrieved. Up to 16 certificates or private keys can be imported. Data for certificate or private key import can be provided with a stream of byte similar to +UDWNFILE or from a file stored on the FS.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response Test AT+USECMNG=? Example OK +USECMNG: (list of supported s),(list of supported s) OK OK 19.2.
SARA-R4/N4 series - AT Commands Manual 19.3 SSL/TLS security layer profile manager +USECPRF +USECPRF Modules Attributes SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference +CME Error 19.3.
SARA-R4/N4 series - AT Commands Manual Expected server hostname * * * SNI Trusted root certificate internal name * Pre-shared key used for connection Cipher suite * Password for the client private key Minimum SSL/TLS version SARA-R4 SARA-N4 Certificate validation level Table 22 provides the list the applicability of SSL connection properties depending on the module series.
SARA-R4/N4 series - AT Commands Manual Parameter Type UBX-17003787 - R11 Description o 1: (0x002f) TLS_RSA_WITH_AES_128_CBC_SHA o 2: (0x003C) TLS_RSA_WITH_AES_128_CBC_SHA256 o 3: (0x0035) TLS_RSA_WITH_AES_256_CBC_SHA o 4: (0x003D) TLS_RSA_WITH_AES_256_CBC_SHA256 o 5: (0x000a) TLS_RSA_WITH_3DES_EDE_CBC_SHA o 6: (0x008c) TLS_PSK_WITH_AES_128_CBC_SHA o 7: (0x008d) TLS_PSK_WITH_AES_256_CBC_SHA o 8: (0x008b) TLS_PSK_WITH_3DES_EDE_CBC_SHA o 9: (0x0094) TLS_RSA_PSK_WITH_AES_128_CBC_SHA o 10: (0x0095) TLS_RSA_P
SARA-R4/N4 series - AT Commands Manual 19.3.
SARA-R4/N4 series - AT Commands Manual In the above example the following PEM encoded trusted certificate is used: -----BEGIN CERTIFICATE----MIIEIDCCAwigAwIBAgIQNE7VVyDV7exJ9C/ON9srbTANBgkqhkiG9w0BAQUFADCB qTELMAkGA1UEBhMCVVMxFTATBgNVBAoTDHRoYXd0ZSwgSW5jLjEoMCYGA1UECxMf Q2VydGlmaWNhdGlvbiBTZXJ2aWNlcyBEaXZpc2lvbjE4MDYGA1UECxMvKGMpIDIw MDYgdGhhd3RlLCBJbmMuIC0gRm9yIGF1dGhvcml6ZWQgdXNlIG9ubHkxHzAdBgNV BAMTFnRoYXd0ZSBQcmltYXJ5IFJvb3QgQ0EwHhcNMDYxMTE3MDAwMDAwWhcNMzYw NzE2MjM1OTU5WjCBqTELMAkGA1UEBhMCVVMxFTATBgNVB
SARA-R4/N4 series - AT Commands Manual 20 FTP Proprietary u-blox AT commands. FTP AT commands set can be used for sending and receiving files over the available bearer, transparently retrieving and storing them in the file system. Standard file and directory management operations on the remote FTP server are as well possible. PSD or CSD connection must be activated before using FTP client services.
SARA-R4/N4 series - AT Commands Manual Type Set Syntax AT+UFTP=5[,] Response OK Example AT+UFTP=5,21 OK FTP mode Set AT+UFTP=6[,] OK AT+UFTP=6,1 OK FTP server port Set AT+UFTP=7[,] OK AT+UFTP=7,30 OK FTP Secure option in explicit mode Set AT+UFTP=8[,[, ]] OK Read +UFTP: 0, +UFTP: 0,"216.239.59.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number / String Number / String Description Remote FTP server listening port; it must be a valid TCP port value. The range goes from 1 to 65535; the default value is 21. Enables / disables the Secure option (explicit mode) of FTP client service.
SARA-R4/N4 series - AT Commands Manual Type Set Syntax AT+UFTPC=0 Response OK Example AT+UFTPC=0 OK FTP login Set AT+UFTPC=1 OK AT+UFTPC=1 OK Delete the file from the FTP server Set AT+UFTPC=2, OK AT+UFTPC=2,"mytest" OK Rename a file of FTP server Set AT+UFTPC=3,, OK AT+UFTPC=3,"old_name","final_ name" OK Retrieve the file from the FTP server Set AT+UFTPC=4,, OK [,] Store the file on the FTP server Set A
SARA-R4/N4 series - AT Commands Manual 20.2.3 Defined values Parameter Type Number Description FTP command request. Allowed values: • • String String String String Number Number String String Number UBX-17003787 - R11 0: FTP logout; terminates the FTP session by performing a logout.
SARA-R4/N4 series - AT Commands Manual Parameter Type String Description Data available from the FTP server in the ASCII [0x00,0xFF] range. The starting quotation mark shall not be taken into account like data, the first byte of data starts after the first quotation mark. The total number of bytes is . At the end of the byte stream, another quotation mark is provided for user convenience and visualization purposes.
SARA-R4/N4 series - AT Commands Manual 21 HTTP The section describes the u-blox proprietary AT commands that can be used for sending requests to a remote HTTP server, receiving the server response and transparently storing it in the file system. The supported methods are: HEAD, GET, DELETE, PUT, POST file and POST data. A PSD or CSD connection must be activated before using HTTP AT commands. When these commands report an HTTP error, the error code can be queried using the +UHTTPER AT command.
SARA-R4/N4 series - AT Commands Manual Type Syntax Username Set AT+UHTTP=,2, Read AT+UHTTP=,2 Response Example OK OK AT+UHTTP=2,2,"my_user" OK +UHTTP: ,2, AT+UHTTP=2,2 OK +UHTTP: 2,2,"my_user" OK Password Set AT+UHTTP=,3, Read AT+UHTTP=,3 OK AT+UHTTP=2,3,"pwd" OK +UHTTP: ,3, AT+UHTTP=2,3 OK +UHTTP: 2,3,"pwd" OK Authentication type Set AT+UHTTP=,4,
SARA-R4/N4 series - AT Commands Manual Parameter Type String String Number Number Number String String Number String Number / String Number / String Description • 4: authentication type • 5: HTTP server port • 6: HTTP Secure option (SSL encryption) • 7: reserved for internal use only • 8: reserved for inte
SARA-R4/N4 series - AT Commands Manual 21.2 HTTP advanced control+UHTTPAC +UHTTPAC Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time full No No No - Error reference Appendix A.6 21.2.1 Description Configures, reads or resets (to the factory-programmed values) the HTTP application profile advanced parameters. The configured HTTP profile advanced parameters are not saved in the non volatile memory.
SARA-R4/N4 series - AT Commands Manual Command Example 3 AT+UHTTPAC=0,0,0,"COMPLEX_COOKIE; COMPLEX_ COOKIE" Response Description OK Overwrite HTTP request cookie at index 0 with a complex cookie 21.3 HTTP command +UHTTPC +UHTTPC Modules Attributes SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted Response time partial No No No - Error reference Appendix A.6 21.3.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description - 2: application/octet-stream - 3: multipart/form-data - 4: application/json - 5: application/xml - 6: user defined with o : used only when =6 (user defined Content-Type). The maximum length is 64 characters • 4: POST a file command; issue a POST request for sending a file to the HTTP server.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number String Description HTTP status code reported in the server response header after a GET FOTA update file request. This parameter is issued only for AT+UHTTPC=,100, AT command. MD5 checksum of the FOTA update file. This parameter is issued only for AT +UHTTPC=,100, AT command. 21.3.4 Notes • • • The +UHTTPC command has a default timeout setting set to 180 s.
SARA-R4/N4 series - AT Commands Manual 22 GNSS 22.1 NMEA u-blox cellular modules support reading NMEA strings from the GNSS receiver through AT commands. Before being able to read a specific NMEA string, it is necessary to activate the storage of the last value of that particular NMEA string. If storing a particular NMEA string was not activated, the response to the query will be "0,NULL".
SARA-R4/N4 series - AT Commands Manual ephemeris was intended for. This makes downloading new ephemeris or aiding data for the first fix unnecessary for subsequent start-ups of the receiver. The AssistNow Autonomous feature may be not fully supported on all Multi-GNSS receivers. For more details on AssistNow Autonomous feature see the corresponding u-blox-GNSS receiver description. For a more detailed description on aiding modes and possible suggestions, see the GNSS Implementation Application Note [52].
SARA-R4/N4 series - AT Commands Manual 22.2.4 Notes • • • • To know the allowed combinations of GNSS type for see the corresponding GNSS receiver documentation. If type is not supported by the GNSS receiver, the set command turns on the GNSS receiver with built-in supported type. The current can be queried by means of the read command or the +UUGIND URC.
SARA-R4/N4 series - AT Commands Manual 22.3.
SARA-R4/N4 series - AT Commands Manual • Into a file on the cellular module: A file with GNSS data can be accessed via +ULSTFILE command. The file name is automatically chosen by the cellular module as a unique ID based on date and time or a further incremental number (e.g. "GPS_200910061500" or "GPS_20091006_001" according to the used cellular module). When the files size reaches 500 kB the file is closed and no more data is saved.
SARA-R4/N4 series - AT Commands Manual 22.5 Aiding server configuration +UGSRV +UGSRV Modules SARA-R410M-02B SARA-R410M-52B SARA-N4 Syntax PIN required Settings saved Can be aborted full No NVM No Attributes Response time - Error reference +CME Error 22.5.1 Description Configures the network connection to a Multi GNSS Assistance (MGA) server. The configuration is saved in NVM and applied at the next GNSS power cycle. The MGA server is accessed with the HTTP.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Number Number Number Number Description The number of days into the future the Offline data for u-blox 7 and previous version should be valid for. The allowed values are: 1, 2, 3, 5, 7, 10 and 14. The default and factory-programmed value is 14. The number of weeks into the future the Offline data for u-blox M8 should be valid for.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 1: Download of local aiding data from the cellular module to the GNSS receiver • 2: AssistNow Offline file download request (file loaded into cellular module) • 4: AssistNow Online data download request (data loaded into the GNSS receiver). This is only needed if AssistNow Online is not used with automatic operation • 8: AssistNow autonomous • Other values are reserved for future use 22.
SARA-R4/N4 series - AT Commands Manual 22.8 GNSS indications timer +UGTMR +UGTMR Modules SARA-R410M-02B SARA-R410M-52B SARA-N4 Syntax PIN required Settings saved Can be aborted full No No No Attributes Response time < 10 s Error reference +CME Error 22.8.1 Description Sets the date and time format. With the parameter is possible to set the time zone value; the time and the date will be updated as the local time. With the action command is possible to synchronize the UTC timing. 22.8.
SARA-R4/N4 series - AT Commands Manual 22.9.2 Syntax Type Set Syntax AT+UGZDA= Response OK Example AT+UGZDA=1 Read AT+UGZDA? +UGZDA: ,<$ZDA msg> OK +UGZDA: 1,$GPZDA,142351.00,12,12, 2013,00,00*66 OK OK +UGZDA: 0,NULL Test AT+UGZDA=? +UGZDA: (list of supported s) OK +UGZDA: (0-1) OK OK 22.9.
SARA-R4/N4 series - AT Commands Manual Parameter <$GGA msg> Type String Description NMEA $GGA messages or "Not available" if the NMEA string is enabled, but this information has not been still sent to the user. 22.11 Get geographic position +UGGLL +UGGLL Modules SARA-R410M-02B SARA-R410M-52B SARA-N4 Syntax PIN required Settings saved Can be aborted full No NVM No Attributes Response time < 10 s Error reference +CME Error 22.11.
SARA-R4/N4 series - AT Commands Manual 22.12.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response Test AT+UGRMC=? +UGRMC: (list of supported s) Example OK +UGRMC: (0-1) OK OK 22.13.3 Defined values Parameter Type Number <$RMC msg> String Description • 0 (factory-programmed value): to disable the NMEA $RMC messages • 1: to enable the NMEA $RMC messages NMEA $RMC messages or "Not available" if the NMEA string is enabled, but this information has not been still sent to the user. 22.
SARA-R4/N4 series - AT Commands Manual 22.15 Get satellite information +UGGSA +UGGSA Modules SARA-R410M-02B SARA-R410M-52B SARA-N4 Syntax PIN required Settings saved Can be aborted full No NVM No Attributes Response time < 10 s Error reference +CME Error 22.15.1 Description Enables/disables the storing of the last value of NMEA $GSA messages, and gets the current messaging state.
SARA-R4/N4 series - AT Commands Manual If the +ULOC command is sent while a previous +ULOC activity is still in progress the previous activity is aborted, the available position is immediately output and the next +ULOC request is served. The data connection cannot be immediately dropped at the +ULOC timeout expiration. This could lead to a delay in the expected response time. Depending on the aiding chosen, a data connection could be required; see the AT+UGPS command description.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response ,,,,,,[,, ,,, ,] If =2, = 0: +UULOC: ,,,,
SARA-R4/N4 series - AT Commands Manual Parameter Type Number Number Description Antenna status (0 - 4)(3). For more details see the u-blox GNSS receiver protocol specification Jamming status3. For more details see the u-blox GNSS receiver protocol specification 22.16.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 1: wrong URL • 2: HTTP error • 3: create socket error • 4: close socket error • 5: write to socket error • 6: read from socket error • 7: connection/DNS error • 8: authentication token missing or wrong (required for aiding for u-blox M8 and future versions) • 9: generic error • 10: user terminated • 11: no data from server 22.
SARA-R4/N4 series - AT Commands Manual 22.18.
SARA-R4/N4 series - AT Commands Manual 2 23 I C 23.1 Introduction The I2C AT commands support communication with more than one connected device via one of the controllers, but require opening and closing a logical channel for each connected device. Only one logical channel at a time can be opened. The availability and hardware description of the I2C interfaces are out of the scope of this document and are described in a separate document. Refer to the corresponding module System Integration Manual.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response supported s),(list of supported ),( range),(list of supported s) Example OK OK 23.2.
SARA-R4/N4 series - AT Commands Manual 2 23.4 I C read from peripheral +UI2CR +UI2CR Modules SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full No No No Attributes Response time - Error reference +CME Error 23.4.1 Description Reads of data from the I2C slave device of the current logical channel and prints them in HEX format in separate rows. 23.4.
SARA-R4/N4 series - AT Commands Manual Type Syntax Response OK Example 23.5.3 Defined values Parameter Type Number Number ,..., ,..., Number Description Device address in HEX format Number of bytes to read from the slave I2C register. The range goes from 1 to 100. Index of the byte being printed. n-th byte of the data, in hex mode (unquoted, prefixed by 0x). 2 23.
SARA-R4/N4 series - AT Commands Manual 24 MQTT The MQ Telemetry Transport (MQTT) protocol specifies a simple and lightweight messaging protocol, designed for constrained devices and low-bandwidth, high-latency, or unreliable networks. An MQTT client uses publish and subscribe methods to interact over a TCP connection with an MQTT message broker (henceforth referred to as an MQTT server). The u-blox modules can be configured to operate as an MQTT client.
SARA-R4/N4 series - AT Commands Manual Type Set Syntax AT+UMQTT=1, Response +UMQTT: 1, Example AT+UMQTT=1,1883 OK +UMQTT: 1,1 OK MQTT server name Set AT+UMQTT=2,[, ] +UMQTT: 2, OK AT+UMQTT=2, "www.commercialmqttbroker.com" +UMQTT: 2,1 OK MQTT server IP address Set AT+UMQTT=3,[, AT+UMQTT=3,"192.168.1.
SARA-R4/N4 series - AT Commands Manual Parameter Type String Number String String String String Number Number Number Number Number Number / String Number / String Number Description Uniquely identifies this client connection to a given MQTT message broker.
SARA-R4/N4 series - AT Commands Manual • • • • • indicates that more information from this MQTT parameter remains to be displayed. If the continuation symbol appears on both sides of the double-quotes, then this message is the continuation of a previous display (and requires future displays to complete), e.g., Topic: +"is in the middle of a long messa"+. The profile parameters 6, 7, 8, 9 and 14 are provided in the read response for informational purposes. They cannot be set using the +UMQTT set command.
SARA-R4/N4 series - AT Commands Manual Parameter Type Number String Number Description Whether or not the Will Message will be retained across disconnects: • 0 (default value): the Will Message will not be retained at the MQTT server across disconnects from MQTT client • 1: the Will Message will be retained by the MQTT server across disconnects from MQTT client (until superseded by another message). Standard MQTT Topic Name.
SARA-R4/N4 series - AT Commands Manual 24.4 Save/Restore MQTT profile from NVM +UMQTTNV +UMQTTNV Modules Attributes SARA-R410M-02B SARA-R410M-52B SARA-R412M SARA-N4 Syntax PIN required Settings saved Can be aborted full No No No Response time - Error reference +CME Error 24.4.1 Description Either saves all of the MQTT client profile parameters to NVM (non-volatile memory) or sets all of the MQTT client profile parameters to either default or non-volatile stored values. 24.4.
SARA-R4/N4 series - AT Commands Manual Type Syntax MQTT logout Set AT+UMQTTC=0 Response Example +UMQTTC: 0, AT+UMQTTC=0 OK +UMQTTC: 0,1 OK MQTT login Set AT+UMQTTC=1 URC MQTT publish to a topic Set AT+UMQTTC=2,,, [],, +UMQTTC: 1, AT+UMQTTC=1 OK +UMQTTC: 1,1 +UUMQTTC: 1, OK +UUMQTTC: 1,0 +UMQTTC: 2, OK AT+UMQTTC=2,0,0,"/sensor/heat/ SD/bldg5/DelMarConfRm","23 degrees Celsius" +UMQTTC: 2,1 OK MQTT pub
SARA-R4/N4 series - AT Commands Manual Type Syntax MQTT Message URC Response Example +UUMQTTCM: , [Topic: ] [Len: Qos: ] Message: +UUMQTTCM: 6,1 Topic: /sensor/ heat/SD/bldg5/DelMarConfRm Len: 16 QoS: 0 Message: 16 bytes of data 24.5.
SARA-R4/N4 series - AT Commands Manual Parameter Type Description • 2: the client identifier is correct UTF-8 but not allowed by the Server • 3: the network connection has been made but the MQTT service is unavailable • 4: the data in the user name or password is malformed • 5: the client is not authorized to connect • 6-255: reserved for future use 24.5.4 Notes • • • • The topic name should not include any wildcards for the Publish commands.
SARA-R4/N4 series - AT Commands Manual A Appendix: Error result codes A.
SARA-R4/N4 series - AT Commands Manual Numeric error code 126 132 133 134 135 140 141 142 143 144 145 146 148 149 150 156 159 172 173 174 175 176 254 255 300 301 302 303 304 305 310 311 312 313 314 315 316 317 318 320 321 322 330 331 332 340 500 701 702 1001 1003 1006 1008 1016 1017 UBX-17003787 - R11 Description Insufficient resources Service option not supported Requested service option not subscribed Service option temporarily out of order NS-api already used Feature not supported Semantic error in th
SARA-R4/N4 series - AT Commands Manual Numeric error code 1018 1019 1021 1022 1026 1027 1028 1029 1030 1031 1034 1038 1041 1042 1043 1044 1047 1049 1050 1055 1057 1058 1063 1065 1068 1069 1070 1079 1081 1087 1088 1091 1095 1096 1097 1098 1099 1100 1101 1102 1111 1127 1279 1283 1500 1501 1502 1503 1504 1505 1520 1521 1530 1531 1540 UBX-17003787 - R11 Description No user responding User alerting, no answer Call rejected Number changed Non selected user clearing Destination out of order Invalid number forma
SARA-R4/N4 series - AT Commands Manual Numeric error code 1542 1543 1544 1545 1546 1547 1548 1549 1550 1551 1552 1553 1554 1555 1556 1557 1558 1559 1600 1560 1561 1612 1613 1620 1621 1622 1623 1624 1625 1626 1627 1628 1629 1630 1631 1632 1633 1634 1635 1636 1637 1638 1639 1640 1641 1642 1643 1644 1645 1646 1647 1648 1649 1650 1660 UBX-17003787 - R11 Description LLC or SNDCP failure Regular deactivation Reactivation requested Single address bearers only allowed Invalid transaction identifier value APN res
SARA-R4/N4 series - AT Commands Manual Numeric error code 1700 1701 1702 1703 1704 1705 1706 1707 1708 1709 1710 1711 1712 1713 1801 1802 1803 1804 1805 1806 1900 1901 1902 1903 1904 1910 1911 1912 1913 1914 1950 1951 1952 2000 3000 4000 4001 Description GPS GPIO not configured GPS GPIO ownership error Invalid operation with GPS ON Invalid operation with GPS OFF Invalid GPS aiding mode Reserved GPS aiding mode GPS aiding mode already set Invalid GPS trace mode Parameter valid only in case of GPS OTA GPS t
SARA-R4/N4 series - AT Commands Manual Numeric error code 47 50 69 81 95 96 97 98 99 111 127 128 129 130 143 144 145 159 160 161 175 176 192 193 194 195 196 197 198 199 208 209 210 211 212 213 287 290 296 297 300 301 302 303 305 310 311 312 313 314 315 320 321 322 330 UBX-17003787 - R11 Description Resources unavailable, unspecified Requested facility not subscribed Requested facility not implemented Invalid short message reference value Invalid message, unspecified invalid mandatory information Message
SARA-R4/N4 series - AT Commands Manual Numeric error code 331 332 340 500 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 548 549 555 556 557 558 560 561 562 563 564 565 566 567 UBX-17003787 - R11 Description no network service network timeout no +CNMA acknowledgement expected unknown error Relay Protocol Acknowledgement SMS timer expired SMS forwarding availability failed SMS forwarding availability abort
SARA-R4/N4 series - AT Commands Manual Numeric error code 568 569 571 572 576 577 579 580 581 583 584 585 586 587 590 591 595 601 604 605 606 608 609 610 612 614 615 616 618 619 620 621 622 623 624 625 626 627 628 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 UBX-17003787 - R11 Description Incompatible By Destination Invalid Transit Network Selection Message Not Compatible With Protocol State Recovery On Timer Expiry Data Call Active Speech Call Active MOC Setup Rejected Due to Missing ACM
SARA-R4/N4 series - AT Commands Manual Numeric error code 647 649 650 653 654 656 657 658 659 660 661 662 663 664 665 669 670 671 672 674 675 676 677 680 Description Lower Layer Failure From NW Conditional IE Error No Cell Allocation Available Re Establishment Reject Directed Sigconn Re Establishment Release of RRC connection Witout Network Activity(3G) Lower Layer Failure Downlink Lower Layer Failure Uplink Cell Barred Due To Authentication Failure Signalling Connection Release CS Connection Release Trig
SARA-R4/N4 series - AT Commands Manual Numeric error code 2 Description Resulting from the following commands ENOENT - No such resource (internal error) 4 EINTR - Interrupted system call (internal error) 5 EIO - I/O error (internal error) 9 EBADF - Bad file descriptor (internal error) 10 ECHILD - No child processes (internal error) 11 EWOULDBLOCK / EAGAIN - Current operation would block, try again ENOMEM - Out of memory (internal error) +USOCR, +USOSO, +USOGO, +USOCO, +USOWR, +USOST, +USORD,
SARA-R4/N4 series - AT Commands Manual Numeric error code 104 Description Resulting from the following commands ECONNRESET - Connection reset by peer 105 ENOBUFS - No buffer space available 106 107 EISCONN - Transport endpoint is already connected ENOTCONN - Transport endpoint is not connected 108 ESHUTDOWN - Cannot send after transport endpoint shutdown 110 111 112 ETIMEDOUT - Connection timed out ECONNREFUSED - Connection refused EHOSTDOWN - Host is down 113 EHOSTUNREACH - No route to host
SARA-R4/N4 series - AT Commands Manual Description 6 7 8 10 11 12 Resulting from the following commands Socket error class BSD error codes standard All Dynamic Memory error 0 All Wrong FTP API usage (e.g. missing/null parameters) See the Appendix A.6.1 +UFTPC, +UFTP, +UFTPER Wrong HTTP API usage (e.g. missing/null See the Appendix A.6.
SARA-R4/N4 series - AT Commands Manual Numeric error code 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 226 250 350 421 Description Cannot open FTP data channel Socket invalid parameter Invalid socket No socket available Cannot create socket Cannot bind socket to network interface Cannot resolve hostname Cannot connect socket Cannot get socket name Cannot bind socket to port Socket cannot listen Socket cannot accept Socket would block Soc
SARA-R4/N4 series - AT Commands Manual Numeric error code 501 502 503 504 530 532 550 552 553 Description Syntax error in parameters or arguments Command not implemented Bad sequence of commands Command not implemented for that parameter User not logged in Need account for storing files Requested action not taken. File unavailable, not found, not accessible Requested file action aborted. Exceeded storage allocation Requested action not taken.
SARA-R4/N4 series - AT Commands Manual Numeric error code 37 38 39 40 41 42 43 44 45 46 - 72 73 Description Invalid HTTP parameter server path Invalid HTTP parameter server path length Invalid HTTP parameter content filename length Invalid custom content type string Output file open error Output file close error Output file write error Connection lost Operation not allowed in current state Internal error Secure socket connect error A.6.
SARA-R4/N4 series - AT Commands Manual Numeric error code 5 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 40 41 50 51 60 61 70 71 80 100 110 111 112 113 114 115 116 117 118 120 130 150 151 160 165 166 167 200 201 202 240 241 242 UBX-17003787 - R11 Description Error setting initial Default MQTT values Error creating new MQTT context in response to UMQTT Error in memory allocation for UMQTT command's response Error in UMQTT command number of arguments Error in UMQTT command syntax UMQTT co
SARA-R4/N4 series - AT Commands Manual Numeric error code 250 251 252 350 360 361 370 371 380 381 390 400 410 411 412 500 501 502 600 601 602 603 604 700 701 702 703 704 1000 Description Error in the MQTT Connect callback's parameters Error in the MQTT Subscribe callback's parameters Error in the MQTT Message callback's parameters Error returned when attempting an MQTT Connection Publish parameter invalid Error Error returned when attempting an MQTT Publish Subscribe parameter invalid Error Error returned
SARA-R4/N4 series - AT Commands Manual Numeric error code -20007 -20008 -20009 -20010 -20011 -20012 -20021 -20022 -20023 -20024 -20025 -20026 -20027 -20028 -20029 -20030 -20031 -20032 -20033 -20034 -20035 -20036 -20037 -20038 -20039 -20040 -20041 -20042 -20043 -20044 -20045 -20046 -20047 -20048 -20049 -20050 -150001 -150002 -150003 -150004 -150005 -150006 -150007 -150008 -150009 -150010 -150011 -150012 -150013 -150014 -150015 -150016 -150017 UBX-17003787 - R11 Description Handshake successful (QAPI MQTT)
SARA-R4/N4 series - AT Commands Manual Numeric error code -150018 -150019 -150020 UBX-17003787 - R11 Description End of file (QAPI FS) Invalid ID was passed by the kernel framework (QAPI FS) Unknown error (QAPI FS) A Appendix: Error result codes Page 275 of 308
SARA-R4/N4 series - AT Commands Manual B Appendix: AT Commands List Call control UBX-17003787 - R11 D S0 SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B A AT command • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 276 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 • • • • • • +URDFILE • • • • • • • • • • +URDBLOCK • • • • • • +ULSTFILE SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UDWNFILE +UDELFILE AT command +UDWNBLOCK File System • • • • • • • • • • B Appendix: AT Commands List Page 277 of 308
SARA-R4/N4 series - AT Commands Manual General commands UBX-17003787 - R11 +CGMI +CGMM +CGMR +CGSN +CIMI +CSCS +GMI +GMM +GMR +GSN A/ I SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CCID AT command • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 278 of 308
SARA-R4/N4 series - AT Commands Manual GPIO interface UBX-17003787 - R11 +UGPIOR +UGPIOW SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UGPIOC AT command • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 279 of 308
SARA-R4/N4 series - AT Commands Manual I2C interface UBX-17003787 - R11 +UI2CO +UI2CR +UI2CREGR +UI2CW SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UI2CC AT command • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 280 of 308
SARA-R4/N4 series - AT Commands Manual Internet suite UBX-17003787 - R11 +UFTP +UFTPC +UFTPER +UHTTP +UHTTPAC +UHTTPC +UHTTPER +USECMNG +USECPRF SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UDNSRN AT command • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 281 of 308
SARA-R4/N4 series - AT Commands Manual Localization features UBX-17003787 - R11 +UGGGA +UGGLL +UGGSA +UGGSV +UGIND +UGPRF +UGPS +UGRMC +UGSRV +UGTMR +UGUBX +UGVTG +UGZDA +ULOC +ULOCGNSS +ULOCIND SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UGAOS AT command • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 282 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 +CMEE +CMER +CPWROFF • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • +UCIND +CIND • • • • • • +CTZU +CFUN SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CCLK AT command +CSGT Mobile equipment control and status • • • • • • • • • • • B Appendix: AT Commands List Page 283 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 • • • • +VZWRSRP +VZWRSRQ • • • • • • • • • • +VZWAPNE +URAT • • • • +UMNOPROF • • • • • +UCGED • • • • • • • • • • +UBANDMASK • • • • • • +PACSP • • • • • • +CSQ • • • • • • • • +CREG • • +COPS • +CNUM • +CESQ SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CEDRXS AT command +CEDRXRDP Network service • • • B Appendix: AT Commands List Page 284 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 • • • • • • • • H • • • • D* • • • • • • • • • • +UPSD • • • • • • +UDCONF=76 +CGDEL • • • • • • +UDCONF=75 +CGDCONT • • • • • • +UAUTHREQ +CGATT • • • • • • +CGREG +CGACT • • • • • • • • • • +CGPADDR +CEREG SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CEMODE AT command +CGEREP Packet switched data services • • • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 285 of 308
SARA-R4/N4 series - AT Commands Manual Security UBX-17003787 - R11 +CPIN +CPWD SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CLCK AT command • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 286 of 308
SARA-R4/N4 series - AT Commands Manual Serial interface UBX-17003787 - R11 Q S10 S12 S2 S3 S4 S5 S6 S7 S8 V • • • • • • O • • • • • • E • • • • • • +IPR +ICF • • • • • • • • • +IFC +CMUX • • • • • • &V • • • • • • &S &F • • • • • • &K &D SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B &C AT command • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
SARA-R4/N4 series - AT Commands Manual Serial interface UBX-17003787 - R11 Z \Q SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B X AT command • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 288 of 308
SARA-R4/N4 series - AT Commands Manual Short Messages Service UBX-17003787 - R11 +CRES • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • +UCMGW +CPMS • • • • • • +UCMGS +CNMI • • • • • • +UCMGR +CNMA • • • • • • +UCMGL +CMSS • • • • • • +CSODCP +CMMS • • • • • • +CSMS +CMGW • • • • • • +CSMP +CMGS • • • • • • +CSCA +CMGR • • • • • • +CSAS +CMGL • • • • • • +CRTDCP +CMGF SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02
SARA-R4/N4 series - AT Commands Manual SIM functionalities UBX-17003787 - R11 +CSIM +CUSATR +CUSATW +UBIP +UCUSATA +USIMSTAT SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CLAN AT command • • • • • • • • • • • • • • • • • • • • • • • • • • • • B Appendix: AT Commands List Page 290 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 • • +UTEST • • +UTEMP • • • • • • +URINGCFG • • • • • • • • +UPSV • • • • • +ULWM2MSTAT • • • • • • +ULWM2M=0 • • • • • • • • +ULGASP • • • • • +UHOSTDEV • • • • • • +UFWUPD +UCPSMS • • • • • • +UFWINSTALL +UANTR SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +CPSMS AT command +UFOTACONF System features • • • • • • • • B Appendix: AT Commands List Page 291 of 308
SARA-R4/N4 series - AT Commands Manual UBX-17003787 - R11 +USORD +USORF +USOSEC +USOSO +USOST +USOWR • • • • • • +USOLI • • • • • • +USOGO • • • • • • +USOER +USOCL • • • • • • +USODL +UDCONF=8 • • • • • • +USOCTL +UDCONF=7 • • • • • • +USOCR +UDCONF=6 • • • • • • +USOCO +UDCONF=5 • • • • • • +USOCLCFG +UDCONF=3 SARA R404M-00B R410M-01B R410M-02B R412M-02B R410M-52B N410-02B +UDCONF=2 AT command +UDCONF=1 Internet protocol transport layer • • • • • • • • • • • • • • • •
SARA-R4/N4 series - AT Commands Manual B.1 Parameters stored in profiles The parameter settings of some commands can be stored in the profiles available in the memory module. SARA-R4 / SARA-N4 To partially display these profiles, see the AT&V command description. Not all the parameter setting are displayed through AT&V command.
SARA-R4/N4 series - AT Commands Manual AT command Description S3 Command line termination character Response No formatting character Command line No editing character Connection No completion timeout DCE response No format Result code selection No and call progress monitoring control S4 S5 S7 V X AT interface configuration sharing No Factory-programmed value / Remarks 13 (0x0d corresponds to the carriage return character) 10 (0x0a corresponds to the line feed character) 8 (008 corresponds to the ba
SARA-R4/N4 series - AT Commands Manual AT command +UGVTG Factory-programmed value / Comment 0 (NMEA $VTG messages disabled) +ULGASP Description Get course over ground and ground speed Get GPS time and date LWM2M Host device information Last gasp configuration +ULOCGNSS Configure GNSS sensor • +UPSD +URAT Packet switched data Selection of Radio Access Technology +URINGCFG +USIMSTAT RING line configuration (U)SIM initialization status reporting +USOCLCFG Configure Dormant Close Socket Behavior Ed
SARA-R4/N4 series - AT Commands Manual Category Estimated maximum time to response Call control < 20 s Dial Up to 3 min Network commands Up to 3 min Security Up to 3 min Delete all SMSes < 55 s SMS acknowledgement < 150 s to MT SMS Up to 3 min (<1 s for prompt ">") SIM management < 10 s PDP context activation PDP context deactivation GPIO commands Internet suite (socket connect) Internet suite (socket connect with SSL) Internet suite (socket write) Internet suite (UDP socket write) Internet suite (socket
SARA-R4/N4 series - AT Commands Manual The reload of the AT command profile from the NVM also results in the re-application of the +UPSV setting, which is a shared "AT interface configuration". This must be kept in mind, since the change could have impacts on the communication over the UART interface. As mentioned in Definitions, generally there is not difference in the execution of an AT command among the interfaces. But, there are some exceptions due to interface restrictions.
SARA-R4/N4 series - AT Commands Manual C Appendix: UDP Direct Link workflow C.1 Data from the IP network to the external port When a UDP data packet is received from the network, its payload is forwarded through the external port as soon as possible (according to the HW flow control, if any). Data from IP netw ork Forw ard it to external port (according with HW flow control, if any) Figure 10: Workflow of data from the IP network to the external port C.
SARA-R4/N4 series - AT Commands Manual Event: new data from external port Reset sending timer New data + data into intermediate buffer is < than max_packet_size ? YES Put data into intermediate buffer and w ait sending timer expires or new data Finish, event handled NO Send max_packet_size of data to IP netw ork YES YES Remaining data is >= max packet size? Event: sending timer expires NO Is there any data? Is there any data into the intermediate buffer? NO YES Send data to IP netw ork NO Fi
SARA-R4/N4 series - AT Commands Manual D Appendix: Glossary 2G 3G 3GPP ADC AIeC ADN AMR AP APN ASCII AT BL BSD CB CBM CLI CLIP CLIR COLP COLR CM CPHS CR CS CSD CSG CTS CUG DA DARP DCD DCE DCM DHCP DNS DSR DTE, TE DTMF DTR DUT EARFCN eCall EEP EF EFCGST EFHNBN EFPLMNwAcT eIM EONS EPD ETSI E-UTRAN/EUTRAN FDN UBX-17003787 - R11 2nd Generation 3rd Generation 3rd Generation Partnership Project Analog to Digital Converter Automatically Initiated eCall Abbreviated Dialing Numbers Adaptive Multi Rate Access Poin
SARA-R4/N4 series - AT Commands Manual FOAT FOTA FS FTP FW FWINSTALL GAS GERAN GPIO GPRS GPS GSM HDLC HNB HPLMN HTTP I I2C I2S ICCID ICMP ICP IMEI IMSI InBM IP IRA IRC ISDN ISP IVS L3 LCP LF LNS M2M MCC ME MIeC MMI MN MNC MNO MO MS MSD MSIN MSISDN MSPR MT MWI NAA NAS NITZ NVM ODIS UBX-17003787 - R11 Firmware Over AT Firmware Over The Air File System File Transfer Protocol Firmware Firmware Install Grouping information Alpha String GSM/EDGE Radio Access Network General Purpose Input Output General Packet
SARA-R4/N4 series - AT Commands Manual OLCM PAD P-CID PCN PDP PDU PIN PLMN PPP PSAP PSD PUK QoS RAM RDI RFU RNDIS RI RTC RTP RTS Rx SAP SC SI SIP SIM SMS SMSC SMTP SoR SDIO STA SSID TA TCP TE TFT TP Tx TZ UCS2 UDI UDP UI UICC UIH URC USIM UTRAN UUS1 WLAN UBX-17003787 - R11 On Line Commands Mode Packet Assembler/Disassembler Physical Cell Id Personal Communication Network Packet Data Protocol Protocol Data Unit Personal Identification Number Public Land Mobile Network Point-to-Point Protocol Public Safety
SARA-R4/N4 series - AT Commands Manual Related documents 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. Stevens. TCP/IP Illustrated Volume1 & 2 Addison-Wesley, 1994. 3GPP TS 27.007 - Technical Specification Group Core Network and Terminals; AT command set for User Equipment (UE) 3GPP TS 22.004 - General on supplementary services GSM 02.
SARA-R4/N4 series - AT Commands Manual 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. 55. 56. 57. 58. 59. 60. 61. 62. 63. 64. 65. 66. 67. 68. 69. 70. 71. 72. 73. 74. 75. 76. 77. 78. 79. 80. 81. 82. 83. GSM 04.60 - Digital cellular telecommunications system (Phase 2+); General Packet Radio Service (GPRS); Mobile Station (MS) - Base Station System (BSS) interface; Radio Link Control / Medium Access Control (RLC/MAC) protocol 3GPP TS 05.
SARA-R4/N4 series - AT Commands Manual 84. 85. 86. 87. 88. 89. 90. 91. 92. 93. 94. 95. 96. 97. 98. 99. 100. 101. 102. 103. 104. 105. 106. 107. 108. 109. 110. 111. 112. 113. 114. 115. 116. 117. 118. 119. 120. 121. 122. 3GPP TS 51.010-2 Mobile Station (MS) conformance specification; Part 2: Protocol Implementation Conformance Statement (PICS) proforma specification 3GPP TS 34.
SARA-R4/N4 series - AT Commands Manual 123. 124. 125. 126. 127. 128. 129. 130. 131. 132. 133. 134. 135. 136. 137. 138. 139. 140. 141. 142. 143. 144. 145. 146. 147. 148. 149. 150. 151. 152. 153. 154. 155. 156. 157. 158. 159. RFC 3966 - The tel URI for Telephone Numbers RFC 2141 - URN Syntax RFC 3406 - Uniform Resource Names (URN) Namespace Definition Mechanisms RFC 5031 - A Uniform Resource Name (URN) for Emergency and Other Well-Known Services 3GPP TS 22.
SARA-R4/N4 series - AT Commands Manual Revision history Revision R01 R02 R03 R04 R05 R06 Date 27-Jan-2017 03-Apr-2017 04-May-2017 24-May-2017 19-Jul-2017 30-Oct-2017 Name jole jole jole jole jole Comments Initial release Removed +UPSV. Added +CPSMS. General document clean-up Added SARA-R410M Moved to Advance Information for SARA-R404M Extended document applicability to SARA-R410M-02B. jole Added +ULWM2M, +ULWM2MSTAT and +CNUM. Changed +CPSMS back to it's original 3GPP definition.
SARA-R4/N4 series - AT Commands Manual Contact For complete contact information, visit us at www.u-blox.com. u-blox Offices North, Central and South America Headquarters Asia, Australia, Pacific Europe, Middle East, Africa u-blox America, Inc. Phone: +1 703 483 3180 E-mail: info_us@u-blox.com u-blox AG Phone: +41 44 722 74 44 E-mail: info@u-blox.com Support: support@u-blox.com u-blox Singapore Pte. Ltd. Phone: +65 6734 3811 E-mail: info_ap@u-blox.com Support: support_ap@u-blox.