Integration Manual
TOBY-L2 and MPCI-L2 series - System Integration Manual
UBX-13004618 - R04 Advance Information System description
Page 19 of 141
Operating Mode
Description
Transition between operating modes
Connected-Mode
RF Tx/Rx data connection is in progress.
The module is prepared to accept data signals from
an external device unless power saving configuration
is enabled by AT+UPSV (see sections 1.9.1.4, 1.9.2.4
and u-blox AT Commands Manual [3]).
When a data connection is initiated, the module enters
connected-mode from idle-mode.
If power saving configuration is enabled by the AT+UPSV
command, the module automatically switches from
connected to active and then idle-mode whenever possible
and the module wakes up from idle to active and then
connected mode if RF Transmission/Reception is necessary.
When a data connection is terminated, the module returns
to the active-mode.
Table 6: TOBY-L2 and MPCI-L2 series modules operating modes description
Figure 3 describes the transition between the different operating modes.
TOBY-L2 Switch ON:
• Apply VCC
MPCI-L2 Switch ON:
• Apply 3.3Vaux
If power saving is enabled
and there is no activity for
a defined time interval
Any wake up event described
in the module operating
modes summary table above
Incoming/outgoing call or
other dedicated device
network communication
No RF Tx/Rx in progress,
Call terminated,
Communication dropped
TOBY-L2x0
Switch ON:
• PWR_ON
• RESET_N
• RTC alarm
Not
powered
Power off
ActiveConnected Idle
TOBY-L2x0
Switch OFF:
• AT+CPWROFF
• RESET_N
MPCI-L2:
• Remove 3.3Vaux
TOBY-L2:
• Remove VCC
Figure 3: TOBY-L2 and MPCI-L2 series modules operating modes transition