1.15.16 Power saving
The power saving configuration is by default disabled, but it can be enabled using the AT+UPSV command (for
the complete description of the AT+UPSV command, see the u-blox AT Commands Manual [3]).
When power saving is enabled, the module automatically enters the low power idle-mode whenever possible,
reducing current consumption (see section 1.5.1.5, TOBY-L2 Data Sheet [1] and MPCI-L2 Data Sheet [2]).
During the low power idle-mode, the module is not ready to communicate with an external device, as it is
configured to reduce power consumption. The module wakes up from low power idle-mode to active-mode in
the following events:
Automatic periodic monitoring of the paging channel for the reception of the paging block sent by the base
station according to network conditions (see section 1.5.1.5)
The connected USB host forces a remote wakeup of the module as USB device (see section 1.9.1.4)
Automatic periodic enable of the UART interface to receive / send data, with AT+UPSV=1 (see 1.9.2.4)
Data received on UART interface, with HW flow control disabled and power saving enabled (see 1.9.2.4)
RTS input set ON by the host DTE, with HW flow control disabled and AT+UPSV=2 (see 1.9.2.4)
DTR input set ON by the host DTE, with AT+UPSV=3 (see 1.9.2.4)
The connected SDIO device forces a wakeup of the module as SDIO host (see 1.9.4)
A preset RTC alarm occurs (see u-blox AT Commands Manual [3], AT+CALA)