Integration Manual

Table Of Contents
TOBY-L2 and MPCI-L2 series - System Integration Manual
UBX-13004618 - R26 System description
Page 56 of 162
1.9.3 DDC (I
2
C) interface
The I
2
C bus compatible Display Data Channel interface is not available on the MPCI-L2 series modules.
The I
2
C bus compatible Display Data Channel interface is not supported by the TOBY-L2 series modules
“00”, “01”, “60” and TOBY-L201-02S product versions.
The SDA and SCL pins of TOBY-L2 series modules represent an I
2
C bus compatible Display Data Channel (DDC)
interface for the communication with external I
2
C devices as audio codecs: an I
2
C master can communicate with
more I
2
C slaves in accordance to the I
2
C bus specifications [13].
The AT commands interface is not available on the DDC (I
2
C) interface.
DDC (I
2
C) slave-mode operation is not supported: the TOBY-L2 series module can act as I
2
C master only.
The DDC (I
2
C) interface pads of the module, serial data (SDA) and serial clock (SCL), are open drain output and
external pull up resistors must be used conforming to the I
2
C bus specifications [13].
1.9.4 Secure Digital Input Output interface (SDIO)
Secure Digital Input Output interface is not available on MPCI-L2 series modules.
Secure Digital Input Output interface is not supported by TOBY-L2 00, “01”, “60” product versions.
TOBY-L2 series modules include a 4-bit Secure Digital Input Output interface (SDIO_D0, SDIO_D1, SDIO_D2,
SDIO_D3, SDIO_CLK, SDIO_CMD) designed to communicate with an external u-blox short range Wi-Fi module:
the TOBY-L2 cellular module acts as an SDIO host controller which can communicate over the SDIO bus with a
compatible u-blox short range Wi-Fi module acting as SDIO device.
The SDIO interface is the only one interface of TOBY-L2 series modules dedicated for communication between the
u-blox cellular module and the u-blox short range Wi-Fi module. The AT commands interface is not available on
the SDIO interface of TOBY-L2 series modules.
The SDIO interface supports 50 MHz bus clock frequency, which allows a data throughput of 200 Mb/s.
Combining a u-blox cellular module with a u-blox short range communication module gives designers full access
to the Wi-Fi module directly via the cellular module, so that a second interface connected to the Wi-Fi module is
not necessary. AT commands via the AT interfaces of the cellular module (UART, USB) allows a full control of the
Wi-Fi module from any host processor, because Wi-Fi control messages are relayed to the Wi-Fi module via the
dedicated SDIO interface (for more details, see the Wi-Fi AT commands in the u-blox AT Commands Manual [3]).
u-blox has implemented special features in the cellular modules to ease the design effort for the integration of a
u-blox cellular module with a u-blox short range Wi-Fi module to provide Router functionality (for more details,
see the Wi-Fi / Cellular Integration Application Note [15]).
Additional custom function over GPIO pins is designed to improve the integration with u-blox Wi-Fi modules:
Wi-Fi enable Switch-on / switch-off the Wi-Fi
GPIOs are not supported by TOBY-L2 “00”, “01” and “60” product versions, except for the Wireless Wide
Area Network status indication configured on GPIO1 pin.
GPIOs are not available on MPCI-L2 series modules.