Integration Manual
Table Of Contents
- Preface
- Contents
- 1 System description
- 1.1 Overview
- 1.2 Architecture
- 1.3 Pin-out
- 1.4 Operating modes
- 1.5 Supply interfaces
- 1.5.1 Module supply input (VCC or 3.3Vaux)
- 1.5.1.1 VCC or 3.3Vaux supply requirements
- 1.5.1.2 VCC or 3.3Vaux current consumption in 2G connected-mode
- 1.5.1.3 VCC or 3.3Vaux current consumption in 3G connected mode
- 1.5.1.4 VCC or 3.3Vaux current consumption in LTE connected-mode
- 1.5.1.5 VCC or 3.3Vaux current consumption in cyclic idle/active mode (power saving enabled)
- 1.5.1.6 VCC or 3.3Vaux current consumption in fixed active-mode (power saving disabled)
- 1.5.2 RTC supply input/output (V_BCKP)
- 1.5.3 Generic digital interfaces supply output (V_INT)
- 1.5.1 Module supply input (VCC or 3.3Vaux)
- 1.6 System function interfaces
- 1.7 Antenna interface
- 1.8 SIM interface
- 1.9 Data communication interfaces
- 1.10 Audio
- 1.11 General Purpose Input/Output
- 1.12 Mini PCIe specific signals (W_DISABLE#, LED_WWAN#)
- 1.13 Reserved pins (RSVD)
- 1.14 Not connected pins (NC)
- 1.15 System features
- 1.15.1 Network indication
- 1.15.2 Antenna supervisor
- 1.15.3 Jamming detection
- 1.15.4 IP modes of operation
- 1.15.5 Dual stack IPv4/IPv6
- 1.15.6 TCP/IP and UDP/IP
- 1.15.7 FTP
- 1.15.8 HTTP
- 1.15.9 SSL / TLS
- 1.15.10 Bearer Independent Protocol
- 1.15.11 Wi-Fi integration
- 1.15.12 Firmware update Over AT (FOAT)
- 1.15.13 Firmware update Over The Air (FOTA)
- 1.15.14 Smart temperature management
- 1.15.15 SIM Access Profile (SAP)
- 1.15.16 Power saving
- 2 Design-in
- 2.1 Overview
- 2.2 Supply interfaces
- 2.2.1 Module supply (VCC or 3.3Vaux)
- 2.2.1.1 General guidelines for VCC or 3.3Vaux supply circuit selection and design
- 2.2.1.2 Guidelines for VCC or 3.3Vaux supply circuit design using a switching regulator
- 2.2.1.3 Guidelines for VCC or 3.3Vaux supply circuit design using a Low Drop-Out linear regulator
- 2.2.1.4 Guidelines for VCC supply circuit design using a rechargeable Li-Ion or Li-Pol battery
- 2.2.1.5 Guidelines for VCC supply circuit design using a primary (disposable) battery
- 2.2.1.6 Additional guidelines for VCC or 3.3Vaux supply circuit design
- 2.2.1.7 Guidelines for external battery charging circuit
- 2.2.1.8 Guidelines for external battery charging and power path management circuit
- 2.2.1.9 Guidelines for VCC or 3.3Vaux supply layout design
- 2.2.1.10 Guidelines for grounding layout design
- 2.2.2 RTC supply output (V_BCKP)
- 2.2.3 Generic digital interfaces supply output (V_INT)
- 2.2.1 Module supply (VCC or 3.3Vaux)
- 2.3 System functions interfaces
- 2.4 Antenna interface
- 2.5 SIM interface
- 2.6 Data communication interfaces
- 2.7 Audio interface
- 2.8 General Purpose Input/Output
- 2.9 Mini PCIe specific signals (W_DISABLE#, LED_WWAN#)
- 2.10 Reserved pins (RSVD)
- 2.11 Module placement
- 2.12 TOBY-L2 series module footprint and paste mask
- 2.13 MPCI-L2 series module installation
- 2.14 Thermal guidelines
- 2.15 ESD guidelines
- 2.16 Schematic for TOBY-L2 and MPCI-L2 series module integration
- 2.17 Design-in checklist
- 3 Handling and soldering
- 4 Approvals
- 4.1 Product certification approval overview
- 4.2 US Federal Communications Commission notice
- 4.3 Innovation, Science and Economic Development Canada notice
- 4.4 Brazilian Anatel certification
- 4.5 European Conformance CE mark
- 4.6 Australian Regulatory Compliance Mark
- 4.7 Taiwanese NCC certification
- 4.8 Japanese Giteki certification
- 5 Product testing
- Appendix
- A Migration between TOBY-L1 and TOBY-L2
- B Glossary
- Related documents
- Revision history
- Contact
TOBY-L2 and MPCI-L2 series - System Integration Manual
UBX-13004618 - R26 Preface
Page 3 of 162
This document applies to the following products:
Name
Type number
Modem version
Application version
PCN reference
Product status
TOBY-L200
TOBY-L200-00S-00
09.71
A01.15
UBX-14044437
Obsolete
TOBY-L200-00S-01
09.71
A01.30
UBX-16026448
Obsolete
TOBY-L200-02S-00
15.90
A01.00
UBX-15029946
Obsolete
TOBY-L200-02S-01
15.90
A01.10
UBX-16031212
End of Life
TOBY-L200-03S-00
15.90
A01.50
UBX-17022983
Mass Production
TOBY-L201
TOBY-L201-01S-00
09.93
A01.07
UBX-18012849
End of Life
TOBY-L201-02S-00
(for AT&T): 09.93
(for AT&T): A02.50
UBX-17013932
Mass Production
(for VZW): 09.94
(for VZW): A01.02
UBX-17013932
Mass Production
TOBY-L210
TOBY-L210-00S-00
09.71
A01.15
UBX-14044437
Obsolete
TOBY-L210-02S-00
15.63
A01.03
UBX-15029946
Obsolete
TOBY-L210-02S-01
15.63
A01.10
UBX-16031212
End of Life
TOBY-L210-03A-00
15.63
A01.60
UBX-18010749
Mass Production
TOBY-L210-03S-00
15.63
A01.50
UBX-17022983
Mass Production
TOBY-L210-60S-00
09.94
A01.00
UBX-15021694
Obsolete
TOBY-L210-60S-01
09.94
A01.01
UBX-16005471
Obsolete
TOBY-L210-62S-00
16.05
A01.02
UBX-17003573
Initial Production
TOBY-L220
TOBY-L220-02S-00
15.93
A01.00
UBX-16025501
Initial Production
TOBY-L220-62S-00
16.04
A01.00
UBX-17013073
Initial Production
TOBY-L280
TOBY-L280-02S-00
15.63
A01.03
UBX-15029946
Obsolete
TOBY-L280-02S-01
15.63
A01.10
UBX-16031212
End of Life
TOBY-L280-03S-00
15.63
A01.50
UBX-17022983
Mass Production
MPCI-L200
MPCI-L200-00S-00
09.71
A01.15
UBX-14044437
Obsolete
MPCI-L200-00S-01
09.71
A01.30
UBX-16026448
Obsolete
MPCI-L200-02S-00
15.90
A01.00
UBX-15029946
Obsolete
MPCI-L200-02S-01
15.90
A01.10
UBX-16031212
End of Life
MPCI-L200-03S-00
15.90
A01.50
UBX-17022983
Mass Production
MPCI-L201
MPCI-L201-01S-00
09.93
A01.07
UBX-18012849
End of Life
MPCI-L201-02S-00
(for AT&T): 09.93
(for AT&T): A02.50
UBX-17013932
Mass Production
(for VZW): 09.94
(for VZW): A01.02
UBX-17013932
Mass Production
MPCI-L210
MPCI-L210-00S-00
09.71
A01.15
UBX-14044437
Obsolete
MPCI-L210-02S-00
15.63
A01.03
UBX-15029946
Obsolete
MPCI-L210-02S-01
15.63
A01.10
UBX-16031212
End of Life
MPCI-L210-03S-00
15.63
A01.50
UBX-17022983
Mass Production
MPCI-L210-60S-00
09.94
A01.00
UBX-15021694
Obsolete
MPCI-L210-60S-01
09.94
A01.01
UBX-16005471
Mass Production
MPCI-L220
MPCI-L220-02S-00
15.93
A01.00
UBX-16025501
Initial Production
MPCI-L220-62S-00
16.04
A01.00
UBX-17013073
Initial Production
MPCI-L280
MPCI-L280-02S-00
15.63
A01.03
UBX-15029946
Obsolete
MPCI-L280-02S-01
15.63
A01.10
UBX-16031212
End of Life
MPCI-L280-03S-00
15.63
A01.50
UBX-17022983
Mass Production
u-blox reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in
whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or
any part thereof without the express permission of u-blox is strictly prohibited.
The information contained herein is provided “as is” and u-blox assumes no liability for the use of the information. No warranty, either express
or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the
information. This document may be revised by u-blox at any time. For most recent documents, please visit www.u-blox.com.
Copyright © 2018, u-blox AG
u-blox is a registered trademark of u-blox Holding AG in the EU and other countries. PCI, PCI Express, PCIe, and PCI-SIG are trademarks or
registered trademarks of PCI-SIG. Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries. All other registered trademarks or trademarks mentioned in this document are property of their respective
owners.