User's Manual

Table Of Contents
SARA-G3 and SARA-U2 series - System Integration Manual
Figure 14 roughly describes the current consumption profile of the SARA-G300 and SARA-G310 modules (when
their EXT32K input is not fed by a signal, i.e. left unconnected), or the SARA-G340 and SARA-G350 modules
(‘00’ versions only), or the SARA-U2 modules, when power saving is disabled: the module is registered with the
network, active-mode is maintained, and the receiver and the DSP are periodically activated to monitor the
paging channel for paging block reception.
ACTIVE MODE
10-18 mA
60-120 mA
2G case: 0.47-2.12 s
3G case: 0.64-5.12 s
Paging period
Time [s]
Current [mA]
100
50
0
Time [ms]
Current [mA]
100
50
0
10-18 mA
60-120 mA
RX
Enabled
20-40 mA
DSP
Enabled
10-18 mA
Figure 14: VCC current consumption profile versus time of the SARA-G300 and SARA-G310 modules (when their EXT32K input is
not fed by a signal), or the SARA-G340 and SARA-G350 modules (‘00’ versions only), or the SARA-U2 modules, when registered
with the network, with power saving disabled: the active-mode is always held, and the receiver and the DSP are periodically
activated to monitor the paging channel
For detailed current consumption values with the module registered with 2G or 3G network with power saving
disabled (fixed active-mode) see the SARA-G3 series Data Sheet [1] and SARA-U2 series Data Sheet [2].
UBX-13000995 - R12 Early Production Information System description
Page 27 of 196