User's Manual

Table Of Contents
SARA-G3 and SARA-U2 series - System Integration Manual
Table 62 lists the maximum input and equivalent parameters that must be considered in sub-division IIB and IIA
for SARA-G350 ATEX and SARA-U270 ATEX.
Parameter SARA-G350 ATEX SARA-U270 ATEX
Ui 4.2 V 4.2 V
Ii 2.5 A (burst) 2.5 A (burst)
Pi 2.5 W TBD W
Ci 103 µF 132 µF
Li 4.1 µH 9.8 µH
Table 62: Maximum input and equivalent parameters for sub-division IIB and IIA
UBX-13000995 - R12 Early Production Information Approvals