Gas group II subdivision RF threshold power limits according to the IEC 60079-0 ATEX standard
IIA (a typical gas is propane) 6.0 W
IIB (a typical gas is ethylene) 3.5 W
IIC (a typical gas is hydrogen) 2.0 W
Table 60: RF threshold power limits for the different gas group II subdivisions according to the IEC 60079-0 ATEX standard [32]
The system antenna(s) implemented/used on the application device integrating SARA-G350 ATEX module
or SARA-U270 ATEX module must be designed/selected so that the antenna gain (i.e. the combined
transmission line, connector, cable losses and radiating element gain) multiplied by the output power of
the module does not exceed the limits shown in Table 60.
UBX-13000995 - R12 Early Production Information Design-in