User's Manual

Table Of Contents
SARA-G3 and SARA-U2 series - System Integration Manual
UBX-13000995 - R08 Objective Specification System description
Page 28 of 188
Figure 14 roughly describes the current consumption profile of SARA-G340, SARA-G350, SARA-U2 series or the
current consumption profile of SARA-G300 / SARA-G310 modules when their EXT32K input is not fed by a
signal (left unconnected), when power saving is disabled: the module is registered with the network, active-
mode is maintained, and the receiver and the DSP are periodically activated to monitor the paging channel for
paging block reception.
ACTIVE MODE
10-18 mA
60-120 mA
2G case: 0.47-2.12 s
3G case: 0.64-5.12 s
Paging period
Time [s]
Current [mA]
100
50
0
Time [ms]
Current [mA]
100
50
0
10-18 mA
60-120 mA
RX
Enabled
20-40 mA
DSP
Enabled
10-18 mA
Figure 14: VCC current consumption profile versus time of SARA-G340, SARA-G350, SARA-U2 series or SARA-G300, SARA-G310
(with the EXT32K input pin not fed by any 32 kHz signal), when registered with the network, with power saving disabled:
the active-mode is always held, and the receiver and the DSP are periodically activated to monitor the paging channel
For detailed current consumption values with the module registered with 2G or 3G network with power saving
disabled (fixed active-mode) see the SARA-G3 series Data Sheet [1] and SARA-U2 series Data Sheet [2].