Integration Manual
Table Of Contents
- Document Information
- Contents
- 1 System description
- 1.1 Overview
- 1.2 Architecture
- 1.3 Pin-out
- 1.4 Operating modes
- 1.5 Power management
- 1.6 System functions
- 1.7 RF connection
- 1.8 (U)SIM interface
- 1.9 Serial communication
- 1.9.1 Serial interfaces configuration
- 1.9.2 Asynchronous serial interface (UART)
- 1.9.2.1 UART features
- 1.9.2.2 UART signal behavior
- 1.9.2.3 UART and power-saving
- 1.9.2.4 UART application circuits
- Providing the full RS-232 functionality (using the complete V.24 link)
- Providing the TxD, RxD, RTS, CTS and DTR lines only (not using the complete V.24 link)
- Providing the TxD, RxD, RTS and CTS lines only (not using the complete V.24 link)
- Providing the TxD and RxD lines only (not using the complete V24 link)
- Additional considerations
- 1.9.3 USB interface
- 1.9.4 SPI interface
- 1.9.5 MUX protocol (3GPP TS 27.010)
- 1.10 DDC (I2C) interface
- 1.11 Audio Interface
- 1.12 General Purpose Input/Output (GPIO)
- 1.13 Reserved pins (RSVD)
- 1.14 Schematic for LISA-U2 module integration
- 1.15 Approvals
- 1.15.1 European Conformance CE mark
- 1.15.2 US Federal Communications Commission notice
- 1.15.3 Innovation, Science, Economic Development Canada notice
- 1.15.4 Australian Regulatory Compliance Mark
- 1.15.5 ICASA Certification
- 1.15.6 KCC Certification
- 1.15.7 ANATEL Certification
- 1.15.8 CCC Certification
- 1.15.9 Giteki Certification
- 2 Design-In
- 3 Features description
- 3.1 Network indication
- 3.2 Antenna detection
- 3.3 Jamming Detection
- 3.4 TCP/IP and UDP/IP
- 3.5 FTP
- 3.6 HTTP
- 3.7 SSL/TLS
- 3.8 Dual stack IPv4/IPv6
- 3.9 AssistNow clients and GNSS integration
- 3.10 Hybrid positioning and CellLocate®
- 3.11 Control Plane Aiding / Location Services (LCS)
- 3.12 Firmware update Over AT (FOAT)
- 3.13 Firmware update Over the Air (FOTA)
- 3.14 In-Band modem (eCall / ERA-GLONASS)
- 3.15 SIM Access Profile (SAP)
- 3.16 Smart Temperature Management
- 3.17 Bearer Independent Protocol
- 3.18 Multi-Level Precedence and Pre-emption Service
- 3.19 Network Friendly Mode
- 3.20 Power saving
- 4 Handling and soldering
- 5 Product Testing
- Appendix
- A Migration from LISA-U1 to LISA-U2 series
- A.1 Checklist for migration
- A.2 Software migration
- A.2.1 Software migration from LISA-U1 series to LISA-U2 series modules
- A.3 Hardware migration
- A.3.1 Hardware migration from LISA-U1 series to LISA-U2 series modules
- A.3.2 Pin-out comparison LISA-U1 series vs. LISA-U2 series
- A.3.3 Layout comparison LISA-U1 series vs. LISA-U2 series
- B Glossary
- Related documents
- Revision history
- Contact
LISA-U2 series - System Integration Manual
UBX-13001118 - R25 System description Page 67 of 182
☞ In command mode
6
, if autobauding is disabled, the DTE must always send a dummy “AT” before
each command line: the first character is not ignored if the module is in active mode (i.e. the
module replies “OK”), or it represents the wake-up character if the module is in low-power idle
mode (i.e. the module does not reply).
☞ No wake-up character or dummy “AT” is required from the DTE during a voice or data call since the
module UART interface continues to be enabled and does not need to be woken-up. Furthermore
in data mode
6
, a dummy “AT” would affect the data communications.
Additional considerations
The LISA-U2 series modules are forced to stay in active mode if the USB is connected and not
suspended, and therefore the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 settings are overruled, but
they still have effect on the UART behavior: they configure the UART interface power saving, so that
the UART is enabled / disabled according to the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 settings.
To set the AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 configuration over the USB interface of LISA-U2
modules, the autobauding must be previously disabled on the UART by the +IPR AT command over
the used AT interface (the USB), and this +IPR AT command configuration must be saved in the
module’s non-volatile memory (see the u-blox AT Commands Manual [2]). Then, after the subsequent
module re-boot, AT+UPSV=1, AT+UPSV=2 or AT+UPSV=3 can be issued over the used AT interface
(the USB): all the AT profiles are updated accordingly.